Ultrasound and X-ray Cross-Characterization of a Graded Impedance Impactor used for Shock-Ramp Compression Experiments
Journal Article
·
· Sensing and Imaging
Abstract In this work we perform ultrasound measurements on an impedance graded impactor made by tape casting magnesium, copper, and tungsten. We also destructively extract small representative samples from the part for complementary characterization with x-ray computed tomography. Combining the two data sets enables direct assignment of some of the measured ultrasound features to specific material characteristics identified by x-ray tomography. Our results demonstrate how ultrasound inspection, informed by x-ray computed tomography, can be used to identify sub-millimeter material amalgamations and spatial heterogeneities in this graded material.
- Sponsoring Organization:
- USDOE
- OSTI ID:
- 2204075
- Alternate ID(s):
- OSTI ID: 2204950
- Journal Information:
- Sensing and Imaging, Journal Name: Sensing and Imaging Journal Issue: 1 Vol. 24; ISSN 1557-2072
- Publisher:
- Springer Science + Business MediaCopyright Statement
- Country of Publication:
- United States
- Language:
- English
Similar Records
Fabrication and Characterization of Graded Impedance Gas Gun Impactors from Tape Cast Metal Powders
Fabrication and application of high impedance graded density impactors in light gas gun experiments
Comparative imaging study in ultrasound, MRI, CT, and DSA using a multimodality renal artery phantom
Journal Article
·
2005
· Materials Science and Engineering, A, A427, n/a, January 6, 2006, pp. 83-91
·
OSTI ID:899395
Fabrication and application of high impedance graded density impactors in light gas gun experiments
Journal Article
·
2013
· Review of Scientific Instruments
·
OSTI ID:1226961
+1 more
Comparative imaging study in ultrasound, MRI, CT, and DSA using a multimodality renal artery phantom
Journal Article
·
2011
· Medical Physics
·
OSTI ID:22096897
+1 more