Title: A TOPAS model for lens-based proton radiography

Journal Article · · Biomedical Physics & Engineering Express

Abstract Objective. Proton Radiography can be used in conjunction with proton therapy for patient positioning, real-time estimates of stopping power, and adaptive therapy in regions with motion. The modeling capability shown here can be used to evaluate lens-based radiography as an instantaneous proton-based radiographic technique. The utilization of user-friendly Monte Carlo program TOPAS enables collaborators and other users to easily conduct medical- and therapy- based simulations of the Los Alamos Neutron Science Center (LANSCE). The resulting transport model is an open-source Monte Carlo package for simulations of proton and heavy ion therapy treatments and concurrent particle imaging. Approach. The four-quadrupole, magnetic lens system of the 800-MeV proton beamline at LANSCE is modeled in TOPAS. Several imaging and contrast objects were modelled to assess transmission at energies from 230–930 MeV and different levels of particle collimation. At different proton energies, the strength of the magnetic field was scaled according to βγ, the inverse product of particle relativistic velocity and particle momentum. Main results. Materials with high atomic number, Z, (gold, gallium, bone-equivalent) generated more contrast than materials with low-Z (water, lung-equivalent, adipose-equivalent). A 5-mrad collimator was beneficial for tissue-to-contrast agent contrast, while a 10-mrad collimator was best to distinguish between different high-Z materials. Assessment with a step-wedge phantom showed water-equivalent path length did not scale directly according to predicted values but could be mapped more accurately with calibration. Poor image quality was observed at low energies (230 MeV), but improved as proton energy increased, with sub-mm resolution at 630 MeV. Significance. Proton radiography becomes viable for shallow bone structures at 330 MeV, and for deeper structures at 630 MeV. Visibility improves with use of high-Z contrast agents. This modality may be particularly viable at carbon therapy centers with accelerators capable of delivering high energy protons and could be performed with carbon therapy.

Research Organization:
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
Sponsoring Organization:
USDOE; USDOE Laboratory Directed Research and Development (LDRD) Program; USDOE National Nuclear Security Administration (NNSA)
Grant/Contract Number:
89233218CNA000001
OSTI ID:
2204002
Report Number(s):
LA-UR-21-28343
Journal Information:
Biomedical Physics & Engineering Express, Journal Name: Biomedical Physics & Engineering Express Journal Issue: 6 Vol. 9; ISSN 2057-1976
Publisher:
IOP PublishingCopyright Statement
Country of Publication:
United Kingdom
Language:
English

References (31)

Geant4—a simulation toolkit
  • Agostinelli, S.; Allison, J.; Amako, K.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 506, Issue 3 https://doi.org/10.1016/S0168-9002(03)01368-8
journal July 2003
An 800-MeV proton radiography facility for dynamic experiments
  • King, N. S. P.; Ables, E.; Adams, Ken
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 424, Issue 1 https://doi.org/10.1016/S0168-9002(98)01241-8
journal November 1999
Carbon ion radiotherapy in Japan: an assessment of 20 years of clinical experience journal February 2015
First biological images with high-energy proton microscopy journal March 2013
Analytical simulator of proton radiography and tomography for different detector configurations journal March 2019
Potential Benefits of Scanned Intensity-Modulated Proton Therapy Versus Advanced Photon Therapy With Regard to Sparing of the Salivary Glands in Oropharyngeal Cancer journal March 2011
First Clinical Investigation of Cone Beam Computed Tomography and Deformable Registration for Adaptive Proton Therapy for Lung Cancer journal May 2016
COSY INFINITY Version 9
  • Makino, Kyoko; Berz, Martin
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 558, Issue 1 https://doi.org/10.1016/j.nima.2005.11.109
journal March 2006
The Los Alamos Neutron Science Center
  • Lisowski, Paul W.; Schoenberg, Kurt F.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 562, Issue 2 https://doi.org/10.1016/j.nima.2006.02.178
journal June 2006
Comparison of single and dual energy CT for stopping power determination in proton therapy of head and neck cancer journal April 2018
Imaging with penetrating radiation for the study of small dynamic physical processes journal May 2015
Fiji: an open-source platform for biological-image analysis journal June 2012
High-energy proton imaging for biomedical applications journal June 2016
High order magnetic optics for high dynamic range proton radiography at a kinetic energy of 800 MeV journal January 2016
Commissioning of the PRIOR proton microscope journal February 2016
Inverse-collimated proton radiography for imaging thin materials journal January 2017
Current developments in proton therapy: a review journal October 1993
Adaptive radiation therapy journal January 1997
Patient-specific stopping power calibration for proton therapy planning based on single-detector proton radiography journal February 2015
Review of Particle Physics journal August 2018
Contrast-enhanced proton radiographic sensitivity limits for tumor detection journal October 2021
Tissue mimicking materials for a multi‐imaging modality prostate phantom journal April 2001
First proton radiography of an animal patient journal April 2004
Comparison of organ‐at‐risk sparing and plan robustness for spot‐scanning proton therapy and volumetric modulated arc photon therapy in head‐and‐neck cancer journal October 2015
Proton radiography as a tool for quality control in proton therapy journal April 1995
Proton radiography and tomography with application to proton therapy journal September 2015
A Proton Beam Therapy System Dedicated to Spot-Scanning Increases Accuracy with Moving Tumors by Real-Time Imaging and Gating and Reduces Equipment Size journal April 2014
Cardiac sparing with proton therapy in consolidative radiation therapy for Hodgkin lymphoma journal June 2010
Carbon Ion Therapy: A Modern Review of an Emerging Technology journal February 2020
FLASH Radiotherapy: Current Knowledge and Future Insights Using Proton-Beam Therapy journal September 2020
Proton therapy in clinical practice journal May 2011