DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Recovery of DNA from fired and unfired cartridge casings: comparison of two DNA collection methods

Journal Article · · Forensic Science International. Genetics
 [1];  [1];  [1];  [1];  [2]
  1. Federal Bureau of Investigation (FBI), Quantico, VA (United States). Research and Support Unit, Visiting Scientist Program
  2. Federal Bureau of Investigation (FBI), Quantico, VA (United States). Research and Support Unit

For over 10 years, various studies have attempted to increase the recovery of DNA from ammunition by modifying the DNA collection, extraction, purification, and amplification procedures, with varying levels of success. This study focused on the “soaking” method of Montpetit & O’Donnell [1] and the “rinse-and-swab" method of Bille et al. [2]. First, testing for the presence of exogenous DNA, 210 boxed cartridges (brass, steel, and nickel-plated) from nine manufacturers were swabbed and DNA was extracted, concentrated, and quantified. Extracts that quantified > 0 ng/µL (44 of 210) were amplified and genotyped with GlobalFiler™. Of those, only one extract yielded two alleles indicating that the manufacturing and packaging of ammunition was virtually DNA free. Next, to obtain a baseline comparison of two DNA collection methods on a non-metallic substrate and identify a suitable number of cells to spot on cartridges, different DNA input amounts of primary human adult epidermal keratinocytes (HEKa) were tested. Thereafter, 300 brass and 300 nickel-plated, cartridges were spotted with HEKa cells containing ~5 ng of DNA, fired or unfired, and processed with either method. Finally, five methods representing hybrids of the soaking and rinse-and-swab methods were tested to determine if variations of those methods could be used to increase DNA yield and recovery. The results show that the soaking method consistently yielded more DNA than the rinse-and-swab method from a non-metallic substrate. However, the comparison study demonstrated that both methods performed comparably for cartridges. On average, the soaking method recovered 0.25 ng of DNA (5.1% recovery) and the rinse-and-swab method recovered 0.28 ng (5.8% recovery). However, average recoveries were significantly different among three analysts and considerable variation in yields were observed, possibly due to storage time. Furthermore, consistent with prior reports, the DNA recovered from brass casings was only 16% of that recovered from nickel-plated casings and the average yield of DNA from fired casings was reduced to 67% of unfired casings. Moreover, DNA extracts from brass or nickel-plated casings did not appear to contain amplification inhibitors and only 30/596 appeared severely degraded. Finally, both the published rinse-and-swab and soaking methods yielded more DNA than all modifications of the two methods. Overall, both methods yielded equivalent DNA quantities. Additionally, recovery of DNA from any given cartridge casing may be dependent on storage time as well as the skill, proficiency, and experience of the analyst and may reflect stochastic effects, particularly for casings containing low copy and/or degraded DNA.

Research Organization:
Oak Ridge Institute for Science and Education (ORISE), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE Office of Science (SC)
Grant/Contract Number:
SC0014664
OSTI ID:
1981616
Journal Information:
Forensic Science International. Genetics, Journal Name: Forensic Science International. Genetics Journal Issue: C Vol. 59; ISSN 1872-4973
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English

References (26)

Understanding metal inhibition: The effect of copper (Cu 2+ ) on DNA containing samples journal June 2017
Measurement of 9mm cartridge case external temperatures and its forensic application journal July 2010
Direct STR typing from fired and unfired bullet casings journal August 2019
DNA recovery from unfired and fired cartridge cases: A comparison of swabbing, tape lifting, vacuum filtration, and direct PCR journal December 2020
Development of STR profiles from firearms and fired cartridge cases journal September 2009
Generation of DNA profiles from fabrics without DNA extraction journal February 2010
Cell free DNA as a component of forensic evidence recovered from touched surfaces journal January 2012
An optimized procedure for obtaining DNA from fired and unfired ammunition journal July 2015
DNA profiles generated from a range of touched sample types journal September 2018
Recovery of mtDNA from unfired metallic ammunition components with an assessment of sequence profile quality and DNA damage through MPS analysis journal March 2019
Improved STR profiles from improvised explosive device (IED): fluorescence latent DNA detection and direct PCR journal July 2019
An improved process for the collection and DNA analysis of fired cartridge cases journal May 2020
An assessment of tape-lifts journal July 2020
Touch DNA in forensic science: The use of laboratory-created eccrine fingerprints to quantify DNA loss journal January 2020
Epidermal desquamation journal December 2004
Copper interactions with DNA of chromatin and its role in neurodegenerative disorders journal October 2013
Efficacy of “touch” DNA recovery and room-temperature storage from assault rifle magazines journal March 2020
An investigation of two methods of DNA recovery from fired and unfired 9 mm ammunition journal March 2021
Touch DNA: impact of handling time on touch deposit and evaluation of different recovery techniques: An experimental study journal July 2019
Effects of Cyanoacrylate Fuming, Time After Recovery, and Location of Biological Material on the Recovery and Analysis of DNA from Post-Blast Pipe Bomb Fragments journal September 2009
Optical characterization of epidermal cells and their relationship to DNA recovery from touch samples journal January 2015
How Much DNA Is Lost? Measuring DNA Loss of Short-Tandem-Repeat Length Fragments Targeted by the PowerPlex 16® System Using the Qiagen MinElute Purification Kit journal January 2014
Artificial fingerprints for cross-comparison of forensic DNA and protein recovery methods journal October 2019
Copper Increases the Damage to DNA and Proteins Caused by Reactive Oxygen Species journal January 2005
Trace DNA: A Review, Discussion of Theory, and Application of the Transfer of Trace Quantities of DNA Through Skin Contact journal May 2002
Fingerprints as Evidence for a Genetic Profile: Morphological Study on Fingerprints and Analysis of Exogenous and Individual Factors Affecting DNA Typing journal May 2003