DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Analysis of picosecond coherent anti-Stokes Raman spectra for gas-phase diagnostics

Journal Article · · Journal of the Optical Society of America. Part B, Optical Physics

We present a hybrid frequency- and time-domain solution, applicable to the case of picosecond coherent anti-Stokes Raman scattering (CARS), for gas-phase diagnostics. A solution has been derived based on both physical arguments and four-wave mixing equations for picosecond CARS, with pulse durations that are comparable to the dephasing time scale for gas-phase Raman coherence—a regime where commonly employed solutions for impulsive (femtosecond) or cw (nanosecond) pump/Stokes forcing are not strictly valid. We present the ps-CARS spectrum in the form of incoherent sums of CARS intensity spectra, calculated from the fundamental solution for impulsive pump/Stokes Raman preparation. The solution was examined for temperatures from 1000–3000 K, for four plausible experimental configurations, with laser pulse durations of 50–150 ps, and probe pulse delays from −20 to 240 ps. Approximations based on cw and impulsive pump/Stokes preparation to fit picosecond CARS spectra at atmospheric pressure were examined and the relative thermometric accuracy and computational cost of these approximations were quantified for the case of a zero nonresonant CARS contribution, and a nonresonant susceptibility equal to 10% of the Raman-resonant value at the N 2 bandhead. The nanosecond CARS approximation can result in large fitting errors when the probe pulse time delay is less than the probe pulse duration. Errors as large as 10–20% are observed in the fit temperatures for a zero picosecond probe pulse delay, when the nonresonant background is neglected, largely due to an inability of the time-independent cw model to capture transient frequency spread dephasing effects at the Q -branch bandhead. The inclusion of a nonresonant background results in 40–60% thermometry errors with a nanosecond model at a zero-probe delay. Time-dependent impulsive calculations used for femtosecond CARS better approximate the structure of the N 2 bandhead, reducing temperature fitting errors to 5–10% at a short probe pulse delay. The impulsive approximation results in errors up to 10% at intermediate probe pulse delays, where the coherence of the pump and probe pulses leads to multiple terms in the picosecond CARS solution. Both approximations improve as the probe pulse delay exceeds the probe duration. The nanosecond approximation results in a 2–3% error, while the impulsive model results in differences of less than 1% in some cases. Fits to experimental data obtained using short, ∼60ps pulses at a zero probe time delay and longer 100 ps pulses at a substantial 200 ps delay are presented with accuracies of 1–3% in the fit temperature.

Sponsoring Organization:
USDOE
Grant/Contract Number:
NA0003525
OSTI ID:
1975173
Journal Information:
Journal of the Optical Society of America. Part B, Optical Physics, Journal Name: Journal of the Optical Society of America. Part B, Optical Physics Journal Issue: 6 Vol. 40; ISSN JOBPDE; ISSN 0740-3224
Publisher:
Optical Society of AmericaCopyright Statement
Country of Publication:
United States
Language:
English

References (37)

Time-resolved dynamics of resonant and nonresonant broadband picosecond coherent anti-Stokes Raman scattering signals journal December 2005
Optimizing hybrid rotational femtosecond/picosecond coherent anti-Stokes Raman spectroscopy in nitrogen at high pressures and temperatures journal January 2020
Recent advances in coherent anti-Stokes Raman scattering spectroscopy: Fundamental developments and applications in reacting flows journal April 2010
Picosecond time-resolved pure-rotational coherent anti-Stokes Raman spectroscopy for N_2 thermometry journal January 2009
Vibrational femtosecond/picosecond coherent anti-Stokes Raman scattering with enhanced temperature sensitivity for flame thermometry from 300 to 2400 K: Femtosecond/picosecond coherent anti-Stokes Raman scattering journal June 2015
Quantitative one-dimensional imaging using picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy journal January 2011
Precision of multiplex CARS temperatures using both single-mode and multimode pump lasers journal January 1987
Pure-rotational 1D-CARS spatiotemporal thermometry with a single regenerative amplifier system journal January 2020
Multiparameter spatio-thermochemical probing of flame–wall interactions advanced with coherent Raman imaging journal January 2017
Femtosecond coherent anti-Stokes Raman scattering measurement of gas temperatures from frequency-spread dephasing of the Raman coherence journal December 2006
Comparison of chirped-probe-pulse and hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering for combustion thermometry journal January 2017
Interference-free hybrid fs/ps vibrational CARS thermometry in high-pressure flames journal January 2018
Rotational hydrogen thermometry by hybrid fs/ps coherent anti-Stokes Raman scattering in the plume of a burning metalized propellant journal April 2020
Dual-probe 1D hybrid fs/ps rotational CARS for simultaneous single-shot temperature, pressure, and O 2 /N 2 measurements journal January 2020
Single-Shot Gas-Phase Thermometry by Time-to-Frequency Mapping of Coherence Dephasing journal July 2012
Single-shot femtosecond coherent anti-Stokes Raman-scattering thermometry journal January 2002
In situ determination of N2 broadening coefficients in flames for rotational CARS thermometry journal January 2013
Nitrogen and hydrogen CARS temperature measurements in a hydrogen/air flame using a near-adiabatic flat-flame burner journal May 1997
Spatially and temporally resolved temperature and shock-speed measurements behind a laser-induced blast wave of energetic nanoparticles journal May 2013
High-spatial-resolution one-dimensional rotational coherent anti-Stokes Raman spectroscopy imaging using counterpropagating beams journal January 2012
Thermalization dynamics in a pulsed microwave plasma-enhanced laminar flame journal May 2021
Time- and frequency-dependent model of time-resolved coherent anti-Stokes Raman scattering (CARS) with a picosecond-duration probe pulse journal January 2014
Effects of laser linewidth on coherent antiStokes Raman spectroscopy journal August 1979
Improving Signal-To-Interference Ratio in Rich Hydrocarbon—Air Flames Using Picosecond Coherent Anti-Stokes Raman Scattering journal November 2007
Influence of laser-mode statistics on noise in nonlinear-optical processes—application to single-shot broadband coherent anti-Stokes Raman scattering thermometry journal September 1988
Burst-mode 100  kHz N 2 ps-CARS flame thermometry with concurrent nonresonant background referencing journal January 2021
Theoretical modeling of single-laser-shot, chirped-probe-pulse femtosecond coherent anti-Stokes Raman scattering thermometry journal April 2011
Effects of Laser Linewidth on the Coherent Anti-Stokes Raman Spectroscopy Spectral Profile journal September 1982
Sensitivity of coherent anti-Stokes Raman lineshape to time asymmetry of laser pulses journal October 2014
Time-domain coherent anti-Stokes Raman scattering in terms of the time-delayed Yuratich equation journal August 2014
100-kHz-rate gas-phase thermometry using 100-ps pulses from a burst-mode laser journal January 2015
Theory of femtosecond coherent anti-Stokes Raman scattering spectroscopy of gas-phase transitions journal July 2007
Investigation of optical fibers for coherent anti-Stokes Raman scattering (CARS) spectroscopy in reacting flows journal September 2010
Accurate convolutions of coherent anti-Stokes Raman spectra journal June 1984
Femtosecond CARS on H2 journal August 1999
Broadband coherent anti-Stokes Raman scattering spectroscopy of nitrogen using a picosecond modeless dye laser journal December 2005
Flexible chirp-free probe pulse amplification for kHz fs/ps rotational CARS journal January 2020