Title: Multi-channel front-end ASIC for a 3D position-sensitive detector

Journal Article · · Journal of Instrumentation

Arrays of 3D position-sensitive detectors (3DPSD), operating at room temperature and using cadmium zinc telluride (CZT) and thallium bromide (TIBr) sensors, are suitable for gamma-ray spectrometry in many applications. One detector configuration, the 3D position-sensitive Virtual Frisch-Grid detector (VFG), is particularly advantageous for integrating into large area arrays. The signals generated inside each detector of the array are captured with the anode, cathode and four pads that enable the reconstruction of the position and energy of the ionizing interaction by measurements of amplitude and timing of the signals. For these applications, a low-noise front-end ASIC has been developed, capable of processing bipolar signals (needed because of AC-coupling of certain electrodes). The ASIC can be coupled to an ADC in order to form a compound “waveform digitizer” capable of post-processing the analog signals and determining amplitude and timing information. This paper describes a 32-channel front-end ASIC that is suitable for reading out a 3 × 3 or 4 × 4 element matrix in the VFG configuration. Each channel is composed of a low-noise charge amplifier with an adaptive continuous reset feedback circuit suitable for both positive and negative charge, a first order shaper and a single-to-differential converter output stage. Voltage and current references are all internally generated by 10-bit DACs and the chip is fully controllable with the I2C communication protocol. The readout channel response has been verified using the implemented injection circuit. Linear behavior up to ~75 ke± with the gain of ~80 mV/fC, and up to ~200 ke± with the gain of ~30 mV/fC was demonstrated. In conclusion, the first test result waveforms using a 137Cs radioactive source on a 5 × 5 × 12 mm3 TIBr crystal are reported.

Research Organization:
Brookhaven National Laboratory (BNL), Upton, NY (United States)
Sponsoring Organization:
US Department of Homeland Security (DHS); USDOE Office of Science (SC), Basic Energy Sciences (BES)
Grant/Contract Number:
SC0012704
OSTI ID:
1846364
Report Number(s):
BNL-222791-2022-JAAM
Journal Information:
Journal of Instrumentation, Journal Name: Journal of Instrumentation Journal Issue: 02 Vol. 17; ISSN 1748-0221
Publisher:
Institute of Physics (IOP)Copyright Statement
Country of Publication:
United States
Language:
English

References (11)

Front-end ASIC for spectroscopic readout of virtual Frisch-grid CZT bar sensors
  • Vernon, Emerson; De Geronimo, Gianluigi; Bolotnikov, Aleksey
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 940 https://doi.org/10.1016/j.nima.2019.05.047
journal October 2019
Performance of 8 × 8 × 32 and 10 × 10 × 32 mm3 CdZnTe position-sensitive virtual Frisch-grid detectors for high-energy gamma ray cameras
  • Bolotnikov, A. E.; MacKenzie, J.; Chen, E.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 969 https://doi.org/10.1016/j.nima.2020.164005
journal July 2020
Electronics for high resolution spectroscopy with compound semiconductors
  • Redus, R.; Squillante, M.; Lund, J.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 380, Issue 1-2 https://doi.org/10.1016/s0168-9002(96)00307-5
journal October 1996
Large volume room temperature gamma-ray spectrometers from CdxZn1−xTe
  • Lund, J. C.; VanScyoc, J. M.; James, R. B.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 380, Issue 1-2 https://doi.org/10.1016/s0168-9002(96)00323-3
journal October 1996
3-D position sensitive CdZnTe gamma-ray spectrometers journal February 1999
Thallium bromide radiation detectors journal January 1989
A CMOS fully compensated continuous reset system journal January 2000
Performance Studies of Position-Sensitive Capacitive Frisch-Grid TlBr Detectors conference October 2020
Readout ASIC for 3D position-sensitive detectors conference October 2007
Improved resolution for 3-D position sensitive CdZnTe spectrometers journal October 2004
Factors limiting the performance of CdZnTe detectors journal June 2005

Similar Records

Front-end ASIC for spectroscopic readout of virtual Frisch-grid CZT bar sensors
Journal Article · 2019 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:1529886

ASIC for High Rate 3D Position Sensitive Detectors
Journal Article · 2010 · IEEE Transactions on Nuclear Science · OSTI ID:1020838

READOUT ASIC FOR 3D POSITION-SENSITIVE DETECTORS.
Conference · 2007 · OSTI ID:921924

Related Subjects