Title: Parametric Studies of Heat Pump Water Heater Using Low GWP Refrigerants

Journal Article · · International Journal of Refrigeration

A storage heat pump water heater (HPWH) comprises a vapor compression system and a hot water tank. It can lead to more than 70% energy saving, compared with electric resistance heating. HPWH usually uses a wrapped-tank coil as the water heater. The wrapped coil has a strong interaction with the water tank and impose a new challenge for the engineering design and simulation study. Based on the US DOE/ORNL Heat Pump Design Model (HPDM), i.e., a public-domain, component-based thermal system modelling platform, a segment-to-segment wrapped-tank coil model coupled with a one-dimensional stratified water tank model were developed, which facilitates modeling and design HPWHs having various configurations and components. Additionally, the hardware-based design model was used to evaluate refrigerants having lower global warming potentials to replace R-134a, including R-1234yf, R-1234ze, R-290, R-513A and R-450A, when effects of compressor size, refrigerant charge on 24-hour uniform energy factor (UEF) and first-hour rating (FHR) were investigated.In the drop-in replacements, R-1234ze achieved the best UEF, and R-290 resulted in the lowest UEF. When downsizing the compressor to maximize the UEFs, the UEFs of R-134a, R-290, R1234yf, R-450A and R-513A ascended to the range of 4.4 to 4.53, with R-513A having the highest UEF. The R-1234ze ended up having the lowest UEF of 4.27. Refrigerants having larger volumetric vaporization heat led to higher FHRs if using the fixed-size compressor, that R-290 resulted in the highest FHR.

Research Organization:
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE; USDOE Office of Energy Efficiency and Renewable Energy (EERE), Energy Efficiency Office. Building Technologies Office
Grant/Contract Number:
AC05-00OR22725
OSTI ID:
1814402
Journal Information:
International Journal of Refrigeration, Journal Name: International Journal of Refrigeration Vol. 1; ISSN 0140-7007
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English

References (11)

Correlating equations for laminar and turbulent free convection from a vertical plate journal November 1975
Condensation in horizontal tubes, part 2: new heat transfer model based on flow regimes journal August 2003
A validated model for mixing and buoyancy in stratified hot water storage tanks for use in building energy simulations journal June 2016
Dynamic modeling of a sensible thermal energy storage tank with an immersed coil heat exchanger under three operation modes journal June 2017
Performance modeling and parametric study of a stratified water thermal storage tank journal May 2016
Development of a Hot Water Tank Simulation Program with Improved Prediction of Thermal Stratification in the Tank journal May 2015
Development and validation of quasi-steady-state heat pump water heater model having stratified water tank and wrapped-tank condenser journal March 2018
Model-based optimizations of packaged rooftop air conditioners using low global warming potential refrigerants journal March 2018
Optimal design and environmental, energy and exergy analysis of a vapor compression refrigeration system using R290, R1234yf, and R744 as alternatives to replace R134a journal May 2020
Refrigerants selection for a direct expansion solar assisted heat pump for domestic hot water journal May 2019
Energy, Exergy, and Environmental (3e) Assessments of Various Refrigerants in the Refrigeration Systems with Internal heat Exchanger journal January 2020