DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Discussion and improvement of a blade-type XBPM with coupling suppression by compensating calibration coefficients

Journal Article · · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
 [1];  [2];  [2];  [2];  [3];  [2];  [4];  [5];  [2];  [2];  [2];  [2];  [6]
  1. National Synchrotron Radiation Research Center, Hsinchu (Taiwan); National Taiwan Univ., Taipei (Taiwan)
  2. National Synchrotron Radiation Research Center, Hsinchu (Taiwan)
  3. Argonne National Lab. (ANL), Argonne, IL (United States). Advanced Photon Source (APS)
  4. Univ. of Maryland, College Park, MD (United States)
  5. Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Advanced Light Source (ALS)
  6. National Taiwan Univ., Taipei (Taiwan)

The Taiwan Photon Source (TPS) is a third-generation, 3-GeV storage ring with a design current of 500 mA. To monitor the photon beam stability, blade-type X-ray beam position monitors (XBPMs) are installed to record and monitor the photon beam position. The beam position coordinates involve both the X- and Y-axes, and we must consider coupling effects in the XBPM, which have to be reduced for reliability and optimum precision. This study focuses on the front-end (FE) XBPM calibration via four-blade normalization and suppression matrix compensation. The calibration results show that in the optimal measurement range of +/- 200 mu m, the coupling effect between the X and Y position is suppressed to less than a 1-mu m drift, which satisfies the high-accuracy beam position requirements for user operation. The reliability and precision of the XBPM system improved after applying the serial calibration process developed in this study, and the detailed derivation of each calibration step will be discussed here.

Research Organization:
Argonne National Laboratory (ANL), Argonne, IL (United States)
Sponsoring Organization:
USDOE
Grant/Contract Number:
AC02-06CH11357
OSTI ID:
1767116
Journal Information:
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 953; ISSN 0168-9002
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English

References (8)

Beam position measurements of Indus-2 using X-Ray beam position monitor
  • Dhamgaye, V. P.; Lodha, G. S.; Kane, S. R.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 659, Issue 1 https://doi.org/10.1016/j.nima.2011.08.044
journal December 2011
Correlation study of a beam-position monitor and a photon-beam-position monitor in the PLS-II journal January 2015
Blade-type X-ray beam position monitors for SPring-8 undulator beamlines journal July 2001
The APS X-ray undulator photon beam position monitor and tests at CHESS and NSLS
  • Shu, D.; Rodricks, B.; Barraza, J.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 319, Issue 1-3 https://doi.org/10.1016/0168-9002(92)90531-8
journal August 1992
Response of quadrant detectors to structured beams via convolution integrals journal January 2017
X-ray beam position monitors and their usage at the Taiwan photon source
  • Huang, Chih-Hsien; Wu, Chun-Yi; Chiu, Pei-Chen
  • PROCEEDINGS OF THE 13TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION – SRI2018, AIP Conference Proceedings https://doi.org/10.1063/1.5084684
conference January 2019
New Distortion Correction Algorithm for Two-Dimensional Tetra-Lateral Position-Sensitive Silicon Photomultiplier journal February 2017
Development of an x-ray beam position monitor for TPS EPU beamline front ends journal March 2013