DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: A new waveform analysis technique to extract good energy and position resolution from a dual-axis duo-lateral position-sensitive detector

Abstract

The dual-axis duo-lateral position-sensitive silicon detector was developed to detect charged particles with high quality position and energy resolution. When these detectors were used with conventional signal processing electronics, an empirically determined correction was used to improve energy resolution. In this work, the waveforms from the detector after preamplification are studied in detail to investigate position information contained in the waveforms. A 7.22 MeV/nucleon alpha particle beam was impinged directly on a masked dual-axis duo-lateral detector. Data obtained using a 228Th alpha particle source was also used. Here, by studying the waveform characteristics that give rise to the position-dependent distortions, a new summed trigger analysis method has been developed to significantly improve linearity in position reconstruction without sacrificing energy resolution.

Authors:
 [1]; ORCiD logo [2]; ORCiD logo [2];  [2];  [2]; ORCiD logo [3];  [2];  [2];  [2];  [2];  [2];  [2];  [2]; ORCiD logo [2];  [2];  [2]
  1. Texas A & M Univ., College Station, TX (United States); Mount Holyoke College, South Hadley, MA (United States)
  2. Texas A & M Univ., College Station, TX (United States)
  3. Texas A & M Univ., College Station, TX (United States); Angelo State Univ., San Angelo, TX (United States)
Publication Date:
Research Org.:
Texas A & M Univ., College Station, TX (United States)
Sponsoring Org.:
USDOE National Nuclear Security Administration (NNSA); USDOE Office of Science (SC), Nuclear Physics (NP); National Science Foundation (NSF); Welch Foundation
OSTI Identifier:
1761887
Alternate Identifier(s):
OSTI ID: 1668445
Grant/Contract Number:  
FG02-93ER40773; PHY-1659847; A-1266; NA0003841
Resource Type:
Accepted Manuscript
Journal Name:
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Additional Journal Information:
Journal Volume: 985; Journal ID: ISSN 0168-9002
Publisher:
Elsevier
Country of Publication:
United States
Language:
English
Subject:
73 NUCLEAR PHYSICS AND RADIATION PHYSICS; Radiation detection; Detector development; Signal processing; Silicon; Position-sensitive; Charged particle

Citation Formats

Aslin, M. W., Hannaman, A., Youngs, M. D., McIntosh, A. B., Abbott, A., Adamson, P., Gauthier, J., Hagel, K., Jedele, A., Lui, Y. -W., McIntosh, L. A., Sorensen, M. Q., Tobin, Z. N., Wada, R., Wakhle, A., and Yennello, S. J. A new waveform analysis technique to extract good energy and position resolution from a dual-axis duo-lateral position-sensitive detector. United States: N. p., 2020. Web. doi:10.1016/j.nima.2020.164674.
Aslin, M. W., Hannaman, A., Youngs, M. D., McIntosh, A. B., Abbott, A., Adamson, P., Gauthier, J., Hagel, K., Jedele, A., Lui, Y. -W., McIntosh, L. A., Sorensen, M. Q., Tobin, Z. N., Wada, R., Wakhle, A., & Yennello, S. J. A new waveform analysis technique to extract good energy and position resolution from a dual-axis duo-lateral position-sensitive detector. United States. https://doi.org/10.1016/j.nima.2020.164674
Aslin, M. W., Hannaman, A., Youngs, M. D., McIntosh, A. B., Abbott, A., Adamson, P., Gauthier, J., Hagel, K., Jedele, A., Lui, Y. -W., McIntosh, L. A., Sorensen, M. Q., Tobin, Z. N., Wada, R., Wakhle, A., and Yennello, S. J. Sat . "A new waveform analysis technique to extract good energy and position resolution from a dual-axis duo-lateral position-sensitive detector". United States. https://doi.org/10.1016/j.nima.2020.164674. https://www.osti.gov/servlets/purl/1761887.
@article{osti_1761887,
title = {A new waveform analysis technique to extract good energy and position resolution from a dual-axis duo-lateral position-sensitive detector},
author = {Aslin, M. W. and Hannaman, A. and Youngs, M. D. and McIntosh, A. B. and Abbott, A. and Adamson, P. and Gauthier, J. and Hagel, K. and Jedele, A. and Lui, Y. -W. and McIntosh, L. A. and Sorensen, M. Q. and Tobin, Z. N. and Wada, R. and Wakhle, A. and Yennello, S. J.},
abstractNote = {The dual-axis duo-lateral position-sensitive silicon detector was developed to detect charged particles with high quality position and energy resolution. When these detectors were used with conventional signal processing electronics, an empirically determined correction was used to improve energy resolution. In this work, the waveforms from the detector after preamplification are studied in detail to investigate position information contained in the waveforms. A 7.22 MeV/nucleon alpha particle beam was impinged directly on a masked dual-axis duo-lateral detector. Data obtained using a 228Th alpha particle source was also used. Here, by studying the waveform characteristics that give rise to the position-dependent distortions, a new summed trigger analysis method has been developed to significantly improve linearity in position reconstruction without sacrificing energy resolution.},
doi = {10.1016/j.nima.2020.164674},
journal = {Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment},
number = ,
volume = 985,
place = {United States},
year = {Sat Sep 19 00:00:00 EDT 2020},
month = {Sat Sep 19 00:00:00 EDT 2020}
}

Works referenced in this record:

Chimera: a project of a 4π detector for heavy ion reactions studies at intermediate energy
journal, February 1995


INDRA, a 4π charged product detection array at GANIL
journal, April 1995

  • Pouthas, J.; Borderie, B.; Dayras, R.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 357, Issue 2-3
  • DOI: 10.1016/0168-9002(94)01543-0

A novel Calorimeter Telescope for identification of relativistic heavy-ion reaction channels
journal, June 2006

  • Lozeva, R.; Gerl, J.; Górska, M.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 562, Issue 1
  • DOI: 10.1016/j.nima.2006.02.163

The high resolution array (HiRA) for rare isotope beam experiments
journal, December 2007

  • Wallace, M. S.; Famiano, M. A.; van Goethem, M. -J.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 583, Issue 2-3
  • DOI: 10.1016/j.nima.2007.08.248

A dual-axis dual-lateral position-sensitive detector for charged particle detection
journal, February 2010

  • Soisson, S. N.; Stein, B. C.; May, L. W.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 613, Issue 2
  • DOI: 10.1016/j.nima.2009.11.053

A multi-channel integrated circuit for use in low- and intermediate-energy nuclear physics—HINP16C
journal, April 2007

  • Engel, George L.; Sadasivam, Muthukumar; Nethi, Mythreyi
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 573, Issue 3
  • DOI: 10.1016/j.nima.2006.12.052

LASSA: a large area silicon strip array for isotopic identification of charged particles
journal, November 2001

  • Davin, B.; de Souza, R. T.; Yanez, R.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 473, Issue 3
  • DOI: 10.1016/S0168-9002(01)00295-9

The origin of duo-lateral position-sensitive detector distortions
journal, March 2007

  • Solal, Maurice Cohen
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 572, Issue 3
  • DOI: 10.1016/j.nima.2006.12.042