DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Mass‐balance approach to quantify water distribution in soils based on X ‐ray computed tomography images

Journal Article · · European Journal of Soil Science
DOI: https://doi.org/10.1111/ejss.13005 · OSTI ID:1643715
ORCiD logo [1];  [2];  [3]; ORCiD logo [1]
  1. Department of Plant, Soil and Microbial Sciences Michigan State University East Lansing Michigan USA
  2. Soil Science Department Bilecik Seyh Edebali University Bilecik Turkey
  3. Department of Geophysical Sciences and Center for Advanced Radiation Sources The University of Chicago Chicago Illinois USA, The GeoSoilEnviroCARS Facility at the Advanced Photon Source Argonne National Laboratory Lemont Illinois USA

Abstract X‐ray computed tomography (CT) is commonly used in soil science to quantify distributions of pores, water and solids within soil samples. Particularly promising for liquid visualization is dual‐energy scanning of samples with added dopant solutions. The approach uses solutions of heavy elements as a proxy for the soil water and utilizes the abrupt increase of the mass attenuation coefficient of heavy elements when crossing an X‐ray absorption edge, detectable by dual‐energy CT scanning. However, a key step in visualization of the added liquid is image segmentation. In partially saturated soils, the X‐ray CT images consist of voxels with the presence of solid, liquid and gaseous phases in different ratios. These ratios are generally ignored by the traditional image segmentation methods, which separate image voxels into groups with either zero or complete saturation by either prevailing phase. The objective of this study was to develop and test a new physically based segmentation approach that accounts for partial saturation of image voxels by liquids. We combined a theoretical equation for detected photon intensity with the mass conservation equation to compute saturation of image voxels by dopant solution applied to the soil. This approach was tested on soil micro‐columns with potassium iodide ( KI ) solutions. The proposed approach outperformed the traditional segmentation methods, particularly at low and intermediate water contents. Tests conducted for KI solutions in the concentration ranges from 2 to 20% revealed deterioration of the method accuracy with decreasing dopant concentration in the soil. Based on the results of this study we recommend 10 wt% KI solution for quantifying spatial distribution of liquids in soils using dual‐energy X‐ray microtomography. Highlights We developed a new approach to quantify soil water distribution based on X‐ray CT. This approach accounts for partial saturation of image voxels by liquids. This approach outperforms the standard image segmentation methods. Its application is limited to using dual energy monochromatic X‐ray beams.

Sponsoring Organization:
USDOE
Grant/Contract Number:
AC02-06CH11357
OSTI ID:
1643715
Journal Information:
European Journal of Soil Science, Journal Name: European Journal of Soil Science Journal Issue: 2 Vol. 72; ISSN 1351-0754
Publisher:
Wiley-BlackwellCopyright Statement
Country of Publication:
United Kingdom
Language:
English

References (45)

Image processing of multiphase images obtained via X-ray microtomography: A review journal April 2014
Elements of Modern X-ray Physics book March 2011
An Analysis of Histogram-Based Thresholding Algorithms journal November 1993
Utilization of Information Measure as a Means of Image Thresholding journal September 1994
Minimum error thresholding journal January 1986
Minimum cross entropy thresholding journal April 1993
Image thresholding by minimizing the measures of fuzziness journal January 1995
The distribution and transformations of iodine in the environment journal January 1984
Experimental study of movement and distribution of dense organic contaminants in heterogeneous aquifers journal November 1995
A new method for gray-level picture thresholding using the entropy of the histogram journal March 1985
Moment-preserving thresolding: A new approach journal March 1985
Total and partial mass attenuation coefficients of soil as a function of chemical composition
  • Mudahar, Gurmel S.; Modi, Sanjay; Makhan, Singh
  • International Journal of Radiation Applications and Instrumentation. Part A. Applied Radiation and Isotopes, Vol. 42, Issue 1 https://doi.org/10.1016/0883-2889(91)90118-K
journal January 1991
Mass attenuation coefficients of brazilian soils in the range 10–1450 keV journal March 1994
Using X-ray computed tomography in hydrology: systems, resolutions, and limitations journal October 2002
An iterative algorithm for minimum cross entropy thresholding journal June 1998
Adaptive-window indicator kriging: A thresholding method for computed tomography images of porous media journal April 2013
Observer-dependent variability of the thresholding step in the quantitative analysis of soil images and X-ray microtomography data journal June 2010
Contrast agents for soil investigation with X-ray computed tomography journal January 2014
Localization of soil organic matter in soil aggregates using synchrotron-based X-ray microtomography journal November 2014
X-ray Microtomography Determination of Air−Water Interfacial Area−Water Saturation Relationships in Sandy Porous Media journal April 2008
Adsorption and capillary condensation in porous media: Liquid retention and interfacial configurations in angular pores journal July 1999
Liquid retention and interfacial area in variably saturated porous media: Upscaling from single-pore to sample-scale model journal October 1999
Segmentation of X-ray computed tomography images of porous materials: A crucial step for characterization and quantitative analysis of pore structures: X-RAY CT IMAGE SEGMENTATION journal September 2009
High-speed measurements of three-phase flow using synchrotron X rays journal April 1997
Calibration of a Dual-Energy Gamma Radiation System for Multiple Point Measurements in a Soil journal July 1986
Dual-gamma attenuation for the determination of porous medium saturation with respect to three fluids journal November 1986
Measurement and simulation of one-dimensional transient three-phase flow for monotonic liquid drainage journal June 1988
Dual Energy Gamma-ray Transmission for Coincident Measurement of Water Content and Dry Bulk Density of Soil journal June 1967
Fiji: an open-source platform for biological-image analysis journal June 2012
Tomographic imaging of three‐phase flow experiments journal January 1987
Material content of binary physical mixtures as measured with a dual‐energy beam of γ rays journal December 1974
Using a Computed Tomography Miniscanner in soil Science journal January 1986
Error Analysis of Dual-Energy Gamma Radiation Measurements journal January 1995
Fast nonlocal filtering applied to electron cryomicroscopy
  • Darbon, Jerome; Cunha, Alexandre; Chan, Tony F.
  • 2008 5th IEEE International Symposium on Biomedical Imaging (ISBI 2008), 2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro https://doi.org/10.1109/ISBI.2008.4541250
conference May 2008
Picture Thresholding Using an Iterative Selection Method journal January 1978
A Threshold Selection Method from Gray-Level Histograms journal January 1979
The Analysis of cell Images* journal January 1966
Survey over image thresholding techniques and quantitative performance evaluation journal January 2004
Empirical formulae for mass attenuation and energy absorption coefficients from 1 keV to 20 MeV journal September 2017
Operations Useful for Similarity-Invariant Pattern Recognition journal April 1962
Automatic measurement of sister chromatid exchange frequency. journal July 1977
Assessment of X-Ray Micro-Ct Measurements of Porosity and Solute Concentration Distributions During Diffusion in Porous Geologic Media journal January 2013
Systematic and Random Errors in Dual Gamma Energy Soil Bulk Density and Water Content Measurements journal May 1972
Discrimination of Soil Phases by Dual Energy X-ray Tomography journal July 1999
Non-Local Means Denoising journal January 2011