Use of an Imaging Spectrometer for Characterization of a Cesium Dosimeter Calibration Facility
Journal Article
·
· Health Physics
- Univ. of Michigan, Ann Arbor, MI (United States). Dept. of Nuclear Engineering and Radiological Science; University of Michigan
- Univ. of Michigan, Ann Arbor, MI (United States). Dept. of Nuclear Engineering and Radiological Science
Past investigations into the characterization of a space-constrained 137Cs dosimetry calibration facility did not provide detailed positional measurements of gamma ray spectra. Here in this paper, a commercially available Compton imaging system, or imaging spectrometer, was used to accomplish this. This resulted in both spectral information and point of origin information for the measured gamma rays. The relationship between measured spectra and position was explored relative to a dosimetry phantom. The Compton equation was found to accurately describe the relationship for positions associated with larger scattering angles and was found to be less reliable for those associated with smaller angles.
- Research Organization:
- Univ. of Michigan, Ann Arbor, MI (United States)
- Sponsoring Organization:
- USDOE National Nuclear Security Administration (NNSA), Office of Nonproliferation and Verification Research and Development (NA-22)
- Grant/Contract Number:
- NA0002534; NA0003920
- OSTI ID:
- 1616466
- Journal Information:
- Health Physics, Journal Name: Health Physics Journal Issue: 4 Vol. 118; ISSN 0017-9078
- Publisher:
- Health Physics SocietyCopyright Statement
- Country of Publication:
- United States
- Language:
- English
The Polaris-H imaging spectrometer
|
journal | June 2015 |
137Cs Dosimeter Irradiation Facilities: Calibration Frequency, Precision, and Accuracy
|
journal | January 2017 |
Imaging of Gamma-ray Scatter from a Polymethyl-methacrylate Phantom Using a Compton Imaging Spectrometer
|
journal | January 2017 |
Setup and Characterization of a 137Cs Dosimetry Calibration Source in a Space-constrained Environment
|
journal | January 2018 |
Similar Records
MAGNETIC SPECTROMETER WITH INHOMOGENEOUS FIELD
PRELIMINARY INVESTIGATION OF A FIVE-CRYSTAL SCINTILLATION GAMMA-RAY SPECTROMETER
CONSTRUCTION AND CALIBRATION OF AN ANTI-COMPTON SPECTROMETER
Journal Article
·
1961
· Ukrain. Fiz. Zhur.
·
OSTI ID:4837555
+1 more
PRELIMINARY INVESTIGATION OF A FIVE-CRYSTAL SCINTILLATION GAMMA-RAY SPECTROMETER
Technical Report
·
1958
·
OSTI ID:4237491
CONSTRUCTION AND CALIBRATION OF AN ANTI-COMPTON SPECTROMETER
Technical Report
·
1963
·
OSTI ID:4031650