DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: The CLAS12 beamline and its performance

Abstract

This paper describes the Hall B beamline and its performance during the first year of data-taking operation using the CLAS12 detector. We review the beamline instrumentation used to measure and monitor the beam. This instrumentation led to excellent beam quality for energies ranging from 2.2 to 10.6 GeV at the design luminosity of 1035 cm-2 s-1. The instrumentation includes a Moller polarimeter, which can typically measure the beam polarization to an absolute precision of ~2.5%.

Authors:
; ; ; ; ; ; ; ; ; ; ; ; ; ;
Publication Date:
Research Org.:
Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)
Sponsoring Org.:
USDOE Office of Science (SC), Nuclear Physics (NP)
OSTI Identifier:
1596395
Alternate Identifier(s):
OSTI ID: 1596637; OSTI ID: 1660488
Report Number(s):
JLAB-PHY-19-3115; DOE/OR/23177-4863
Journal ID: ISSN 0168-9002; S0168900220300267; 163421; PII: S0168900220300267
Grant/Contract Number:  
AC05-06OR23177
Resource Type:
Published Article
Journal Name:
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Additional Journal Information:
Journal Name: Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment Journal Volume: 959 Journal Issue: C; Journal ID: ISSN 0168-9002
Publisher:
Elsevier
Country of Publication:
Netherlands
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; electron beam; collimator; polarimeter; beam profile; beam halo

Citation Formats

Baltzell, N., Burkert, V. D., Carvajal, J., Dashyan, N., De Vita, R., Elouadrhiri, L., Kharashvili, G., Kim, A., Paremuzyan, R., Raue, B. A., Sharabian, Y. G., Stepanyan, S., Tiefenback, M., Ungaro, M., and Wild, K. The CLAS12 beamline and its performance. Netherlands: N. p., 2020. Web. doi:10.1016/j.nima.2020.163421.
Baltzell, N., Burkert, V. D., Carvajal, J., Dashyan, N., De Vita, R., Elouadrhiri, L., Kharashvili, G., Kim, A., Paremuzyan, R., Raue, B. A., Sharabian, Y. G., Stepanyan, S., Tiefenback, M., Ungaro, M., & Wild, K. The CLAS12 beamline and its performance. Netherlands. https://doi.org/10.1016/j.nima.2020.163421
Baltzell, N., Burkert, V. D., Carvajal, J., Dashyan, N., De Vita, R., Elouadrhiri, L., Kharashvili, G., Kim, A., Paremuzyan, R., Raue, B. A., Sharabian, Y. G., Stepanyan, S., Tiefenback, M., Ungaro, M., and Wild, K. Wed . "The CLAS12 beamline and its performance". Netherlands. https://doi.org/10.1016/j.nima.2020.163421.
@article{osti_1596395,
title = {The CLAS12 beamline and its performance},
author = {Baltzell, N. and Burkert, V. D. and Carvajal, J. and Dashyan, N. and De Vita, R. and Elouadrhiri, L. and Kharashvili, G. and Kim, A. and Paremuzyan, R. and Raue, B. A. and Sharabian, Y. G. and Stepanyan, S. and Tiefenback, M. and Ungaro, M. and Wild, K.},
abstractNote = {This paper describes the Hall B beamline and its performance during the first year of data-taking operation using the CLAS12 detector. We review the beamline instrumentation used to measure and monitor the beam. This instrumentation led to excellent beam quality for energies ranging from 2.2 to 10.6 GeV at the design luminosity of 1035 cm-2 s-1. The instrumentation includes a Moller polarimeter, which can typically measure the beam polarization to an absolute precision of ~2.5%.},
doi = {10.1016/j.nima.2020.163421},
journal = {Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment},
number = C,
volume = 959,
place = {Netherlands},
year = {2020},
month = {4}
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record
https://doi.org/10.1016/j.nima.2020.163421

Citation Metrics:
Cited by: 6 works
Citation information provided by
Web of Science

Save / Share: