DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Practical considerations for high-speed X-ray pixel array detectors and X-ray sensing materials

Authors:
; ; ; ;
Publication Date:
Sponsoring Org.:
USDOE
OSTI Identifier:
1547808
Grant/Contract Number:  
SC0017631
Resource Type:
Publisher's Accepted Manuscript
Journal Name:
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Additional Journal Information:
Journal Name: Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment Journal Volume: 925 Journal Issue: C; Journal ID: ISSN 0168-9002
Publisher:
Elsevier
Country of Publication:
Netherlands
Language:
English

Citation Formats

Philipp, H. T., Tate, M. W., Shanks, K. S., Purohit, P., and Gruner, S. M. Practical considerations for high-speed X-ray pixel array detectors and X-ray sensing materials. Netherlands: N. p., 2019. Web. doi:10.1016/j.nima.2019.01.066.
Philipp, H. T., Tate, M. W., Shanks, K. S., Purohit, P., & Gruner, S. M. Practical considerations for high-speed X-ray pixel array detectors and X-ray sensing materials. Netherlands. https://doi.org/10.1016/j.nima.2019.01.066
Philipp, H. T., Tate, M. W., Shanks, K. S., Purohit, P., and Gruner, S. M. Wed . "Practical considerations for high-speed X-ray pixel array detectors and X-ray sensing materials". Netherlands. https://doi.org/10.1016/j.nima.2019.01.066.
@article{osti_1547808,
title = {Practical considerations for high-speed X-ray pixel array detectors and X-ray sensing materials},
author = {Philipp, H. T. and Tate, M. W. and Shanks, K. S. and Purohit, P. and Gruner, S. M.},
abstractNote = {},
doi = {10.1016/j.nima.2019.01.066},
journal = {Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment},
number = C,
volume = 925,
place = {Netherlands},
year = {2019},
month = {5}
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record
https://doi.org/10.1016/j.nima.2019.01.066

Citation Metrics:
Cited by: 1 work
Citation information provided by
Web of Science

Save / Share:

Works referenced in this record:

Sub-microsecond x-ray imaging using hole-collecting Schottky type CdTe with charge-integrating pixel array detectors
journal, June 2017


Pixel array detector for X-ray free electron laser experiments
journal, September 2011

  • Philipp, Hugh T.; Hromalik, Marianne; Tate, Mark
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 649, Issue 1
  • DOI: 10.1016/j.nima.2010.11.189

Characterization of CdTe sensors with Schottky contacts coupled to charge-integrating pixel array detectors for X-ray science
journal, December 2016


Entering an era of dynamic structural biology…
journal, May 2018


3D — A proposed new architecture for solid-state radiation detectors
journal, August 1997

  • Parker, S. I.; Kenney, C. J.; Segal, J.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 395, Issue 3
  • DOI: 10.1016/S0168-9002(97)00694-3

A Medium-Format, Mixed-Mode Pixel Array Detector for Kilohertz X-ray Imaging
journal, March 2013


Probing dynamics in quantum materials with femtosecond X-rays
journal, June 2018


Solving structure with sparse, randomly-oriented x-ray data
journal, January 2012

  • Philipp, Hugh T.; Ayyer, Kartik; Tate, Mark W.
  • Optics Express, Vol. 20, Issue 12
  • DOI: 10.1364/OE.20.013129

Radiation damage in macromolecular cryocrystallography
journal, October 2006


X-ray analog pixel array detector for single synchrotron bunch time-resolved imaging
journal, November 2010


Multi-element germanium detectors for synchrotron applications
journal, April 2018


In Situ Time-Resolved Measurements of Extension Twinning During Dynamic Compression of Polycrystalline Magnesium
journal, April 2018

  • Hustedt, C. J.; Lambert, P. K.; Kannan, V.
  • Journal of Dynamic Behavior of Materials, Vol. 4, Issue 2
  • DOI: 10.1007/s40870-018-0152-8

High-speed X-ray imaging pixel array detector for synchrotron bunch isolation
journal, January 2016

  • Philipp, Hugh T.; Tate, Mark W.; Purohit, Prafull
  • Journal of Synchrotron Radiation, Vol. 23, Issue 2
  • DOI: 10.1107/S1600577515022754

Drift mobility and mobility-lifetime products in CdTe:Cl grown by the travelling heater method
journal, December 2005

  • Sellin, P. J.; Davies, A. W.; Lohstroh, A.
  • IEEE Transactions on Nuclear Science, Vol. 52, Issue 6
  • DOI: 10.1109/TNS.2005.855641

Characterization of chromium compensated GaAs as an X-ray sensor material for charge-integrating pixel array detectors
journal, January 2018


Tests of a prototype pixel array detector for microsecond time-resolved X-ray diffraction
journal, November 1999


X-ray tests of a Pixel Array Detector for coherent x-ray imaging at the Linac Coherent Light Source
journal, March 2009


Reconstruction algorithm for single-particle diffraction imaging experiments
journal, August 2009


Hole mobility and Poole‐Frenkel effect in CdTe
journal, January 1973

  • Ottaviani, G.; Canali, C.; Jacoboni, C.
  • Journal of Applied Physics, Vol. 44, Issue 1
  • DOI: 10.1063/1.1661888

Recent Developments in the Fabrication and Operation of Germanium Detectors
journal, November 2007


Improved count rate corrections for highest data quality with PILATUS detectors
journal, March 2012

  • Trueb, P.; Sobott, B. A.; Schnyder, R.
  • Journal of Synchrotron Radiation, Vol. 19, Issue 3, p. 347-351
  • DOI: 10.1107/S0909049512003950

X-ray Imaging of Shock Waves Generated by High-Pressure Fuel Sprays
journal, February 2002


A beginner's guide to radiation damage
journal, February 2009


Characterization results of the JUNGFRAU full scale readout ASIC
journal, February 2016