A second‐generation virtual‐pinhole PET device for enhancing contrast recovery and improving lesion detectability of a whole‐body PET/CT scanner
- Authors:
-
- Mallinckrodt Institute of Radiology, Washington University in St. Louis St. Louis MO 63110USA
- Department of Electrical and Systems Engineering Washington University in St. Louis St. Louis MO 63130USA
- Molecular Imaging Siemens Medical Solutions USA, Inc Knoxville TN 37932USA
- Publication Date:
- Sponsoring Org.:
- USDOE
- OSTI Identifier:
- 1547606
- Grant/Contract Number:
- SC0005157
- Resource Type:
- Publisher's Accepted Manuscript
- Journal Name:
- Medical Physics
- Additional Journal Information:
- Journal Name: Medical Physics Journal Volume: 46 Journal Issue: 9; Journal ID: ISSN 0094-2405
- Publisher:
- Wiley Blackwell (John Wiley & Sons)
- Country of Publication:
- United States
- Language:
- English
Citation Formats
Jiang, Jianyong, Li, Ke, Wang, Qiang, Puterbaugh, Kenneth, Young, John W., Siegel, Stefan B., O'Sullivan, Joseph A., and Tai, Yuan‐Chuan. A second‐generation virtual‐pinhole PET device for enhancing contrast recovery and improving lesion detectability of a whole‐body PET/CT scanner. United States: N. p., 2019.
Web. doi:10.1002/mp.13724.
Jiang, Jianyong, Li, Ke, Wang, Qiang, Puterbaugh, Kenneth, Young, John W., Siegel, Stefan B., O'Sullivan, Joseph A., & Tai, Yuan‐Chuan. A second‐generation virtual‐pinhole PET device for enhancing contrast recovery and improving lesion detectability of a whole‐body PET/CT scanner. United States. https://doi.org/10.1002/mp.13724
Jiang, Jianyong, Li, Ke, Wang, Qiang, Puterbaugh, Kenneth, Young, John W., Siegel, Stefan B., O'Sullivan, Joseph A., and Tai, Yuan‐Chuan. Wed .
"A second‐generation virtual‐pinhole PET device for enhancing contrast recovery and improving lesion detectability of a whole‐body PET/CT scanner". United States. https://doi.org/10.1002/mp.13724.
@article{osti_1547606,
title = {A second‐generation virtual‐pinhole PET device for enhancing contrast recovery and improving lesion detectability of a whole‐body PET/CT scanner},
author = {Jiang, Jianyong and Li, Ke and Wang, Qiang and Puterbaugh, Kenneth and Young, John W. and Siegel, Stefan B. and O'Sullivan, Joseph A. and Tai, Yuan‐Chuan},
abstractNote = {},
doi = {10.1002/mp.13724},
journal = {Medical Physics},
number = 9,
volume = 46,
place = {United States},
year = {2019},
month = {8}
}
Free Publicly Available Full Text
Publisher's Version of Record
https://doi.org/10.1002/mp.13724
https://doi.org/10.1002/mp.13724
Other availability
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.
Works referenced in this record:
Targeted multi-pinhole SPECT
journal, November 2010
- Branderhorst, Woutjan; Vastenhouw, Brendan; van der Have, Frans
- European Journal of Nuclear Medicine and Molecular Imaging, Vol. 38, Issue 3
Feasibility study of a point‐of‐care positron emission tomography system with interactive imaging capability
journal, February 2019
- Jiang, Jianyong; Li, Ke; Komarov, Sergey
- Medical Physics, Vol. 46, Issue 4
Clinical Imaging Characteristics of the Positron Emission Mammography Camera: PEM Flex Solo II
journal, September 2009
- MacDonald, L.; Edwards, J.; Lewellen, T.
- Journal of Nuclear Medicine, Vol. 50, Issue 10
Initial Characterization of a Dedicated Breast PET/CT Scanner During Human Imaging
journal, August 2009
- Bowen, S. L.; Wu, Y.; Chaudhari, A. J.
- Journal of Nuclear Medicine, Vol. 50, Issue 9
Study of a high-resolution PET system using a Silicon detector probe
journal, September 2014
- Brzeziński, K.; Oliver, J. F.; Gillam, J.
- Physics in Medicine and Biology, Vol. 59, Issue 20
Role of Positron Emission Tomography for the Monitoring of Response to Therapy in Breast Cancer
journal, January 2015
- Humbert, O.; Cochet, A.; Coudert, B.
- The Oncologist, Vol. 20, Issue 2
Combined PET/MR Imaging — Technology and Applications
journal, February 2010
- Wehrl, H. F.; Sauter, A. W.; Judenhofer, M. S.
- Technology in Cancer Research & Treatment, Vol. 9, Issue 1
GATE: A Geant4-Based Simulation Platform for PET and SPECT Integrating Movement and Time Management
journal, October 2003
- Santin, G.; Strul, D.; Lazaro, D.
- IEEE Transactions on Nuclear Science, Vol. 50, Issue 5
A High-Resolution PET Demonstrator using a Silicon “Magnifying Glass”
journal, January 2012
- Clinthorne, Neal; Cochran, Eric; Chesi, Enrico
- Physics Procedia, Vol. 37
Monitoring Tumor Response to Therapy with 18F-FLT PET
journal, May 2010
- Weber, W. A.
- Journal of Nuclear Medicine, Vol. 51, Issue 6
Fast List-Mode Reconstruction for Time-of-Flight PET Using Graphics Hardware
journal, February 2011
- Pratx, Guillem; Surti, Suleman; Levin, Craig
- IEEE Transactions on Nuclear Science, Vol. 58, Issue 1
Adaptive Imaging for Lesion Detection Using a Zoom-in PET System
journal, January 2011
- Zhou, Jian; Qi, Jinyi
- IEEE Transactions on Medical Imaging, Vol. 30, Issue 1
A compact high resolution flat panel PET detector based on the new 4-side buttable MPPC for biomedical applications
journal, September 2015
- Wang, Qiang; Wen, Jie; Ravindranath, Bosky
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 794
A combined time-of-flight and depth-of-interaction detector for total-body positron emission tomography: A combined time-of-flight and depth-of-interaction detector
journal, January 2016
- Berg, Eric; Roncali, Emilie; Kapusta, Maciej
- Medical Physics, Vol. 43, Issue 2
Performance evaluation of a very high resolution small animal PET imager using silicon scatter detectors
journal, April 2007
- Park, Sang-June; Rogers, W. Leslie; Huh, Sam
- Physics in Medicine and Biology, Vol. 52, Issue 10
Breast cancer detection using high-resolution breast PET compared to whole-body PET or PET/CT
journal, October 2013
- Kalinyak, Judith E.; Berg, Wendie A.; Schilling, Kathy
- European Journal of Nuclear Medicine and Molecular Imaging, Vol. 41, Issue 2
Micro Insert: A Prototype Full-Ring PET Device for Improving the Image Resolution of a Small-Animal PET Scanner
journal, September 2008
- Wu, H.; Pal, D.; Song, T. Y.
- Journal of Nuclear Medicine, Vol. 49, Issue 10
Image reconstruction and system modeling techniques for virtual-pinhole PET insert systems
journal, April 2012
- Keesing, Daniel B.; Mathews, Aswin; Komarov, Sergey
- Physics in Medicine and Biology, Vol. 57, Issue 9
Comparison of quantitative diagnostic tests: Type I error, power, and sample size
journal, March 1987
- Linnet, Kristian
- Statistics in Medicine, Vol. 6, Issue 2
Improving PET imaging for breast cancer using virtual pinhole PET half-ring insert
journal, September 2013
- Mathews, Aswin John; Komarov, Sergey; Wu, Heyu
- Physics in Medicine and Biology, Vol. 58, Issue 18
Fully 3D list-mode time-of-flight PET image reconstruction on GPUs using CUDA: Fully 3D list-mode time-of-flight PET on GPU-CUDA
journal, December 2011
- Cui, Jing-yu; Pratx, Guillem; Prevrhal, Sven
- Medical Physics, Vol. 38, Issue 12
Positron emission tomography with fluorine-18-deoxyglucose in the detection and staging of breast cancer
journal, June 1993
- Nieweg, Omgo E.; Kim, E. Edmund; Wong, Wai-Hoi
- Cancer, Vol. 71, Issue 12
Radionuclide Methods and Instrumentation for Breast Cancer Detection and Diagnosis
journal, July 2013
- Surti, Suleman
- Seminars in Nuclear Medicine, Vol. 43, Issue 4
Virtual-Pinhole PET
journal, February 2008
- Tai, Y. -C.; Wu, H.; Pal, D.
- Journal of Nuclear Medicine, Vol. 49, Issue 3
An evaluation of polygraphers' judgments: A review from a decision theoretic perspective.
journal, January 1982
- Ben-Shakhar, Gershon; Lieblich, Israel; Bar-Hillel, Maya
- Journal of Applied Psychology, Vol. 67, Issue 6
A silicon PET probe
journal, August 2011
- Studen, A.; Chesi, E.; Cindro, V.
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 648
Real time image reconstruction using GPUs for a surgical PET imaging probe system
conference, October 2009
- Huh, S. S.; Rogers, W. L.
- 2009 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC 2009), 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC)
Update on Time-of-Flight PET Imaging
journal, December 2014
- Surti, S.
- Journal of Nuclear Medicine, Vol. 56, Issue 1
Model-based normalization for iterative 3D PET image reconstruction
journal, July 2002
- Bai, B.; Li, Q.; Holdsworth, C. H.
- Physics in Medicine and Biology, Vol. 47, Issue 15
Total-Body PET: Maximizing Sensitivity to Create New Opportunities for Clinical Research and Patient Care
journal, September 2017
- Cherry, Simon R.; Jones, Terry; Karp, Joel S.
- Journal of Nuclear Medicine, Vol. 59, Issue 1
Clinical Performance of 2 Dedicated PET Scanners for Breast Imaging: Initial Evaluation
journal, August 2012
- Iima, M.; Nakamoto, Y.; Kanao, S.
- Journal of Nuclear Medicine, Vol. 53, Issue 10
Imaging of pulmonary mass lesions with whole-body positron emission tomography and fluorodeoxyglucose
journal, July 1993
- Rege, Sheila D.; Hoh, Carl K.; Glaspy, John A.
- Cancer, Vol. 72, Issue 1
Performance Characteristics of a New LSO PET/CT Scanner With Extended Axial Field-of-View and PSF Reconstruction
journal, June 2009
- Jakoby, Bjoern W.; Bercier, Yanic; Watson, Charles C.
- IEEE Transactions on Nuclear Science, Vol. 56, Issue 3
A simulation study for the design of a prototype insert for whole-body PET scanners
journal, June 2006
- Janecek, M.
- IEEE Transactions on Nuclear Science, Vol. 53, Issue 3
Simple charge division readouts for imaging scintillator arrays using a multi-channel PMT
journal, June 1996
- Siegel, S.; Silverman, R. W.
- IEEE Transactions on Nuclear Science, Vol. 43, Issue 3
Design of a very high-resolution small animal PET scanner using a silicon scatter detector insert
journal, July 2007
- Park, Sang-June; Rogers, W. Leslie; Clinthorne, Neal H.
- Physics in Medicine and Biology, Vol. 52, Issue 15
Theoretical analysis and simulation study of a high-resolution zoom-in PET system
journal, August 2009
- Zhou, Jian; Qi, Jinyi
- Physics in Medicine and Biology, Vol. 54, Issue 17
Multi-resolution image reconstruction for a high-resolution small animal PET device
conference, January 2003
- Clinthorne, N. H.; Rogers, W. L.
- 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515)