DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: A study in using MICROMEGAS to improve particle identification with the TAMU-MDM focal plane detector

Abstract

A MICROMEGAS detection amplifier has been incorporated into the design of the TAMU-MDM focal plane detector with the purpose of improving the energy resolution and thus, the particle identification. Furthermore, beam tests showed a factor of 2 improvement over the original design, from 10%–12% to 4%–6%, for ions with A ≤ 40 at E/A ~ 10–20 MeV.

Authors:
 [1];  [2];  [3];  [3];  [3];  [3];  [4];  [4];  [5];  [5]
  1. Texas A & M Univ., College Station, TX (United States); National Institute of Physics and Nuclear Engineering, Bucharest-Magurele (Romania)
  2. Univ. Paris-Saclay, Gif-sur-Yvette (France)
  3. Texas A & M Univ., College Station, TX (United States)
  4. National Institute of Physics and Nuclear Engineering, Bucharest-Magurele (Romania)
  5. European Organization for Nuclear Research (CERN), Geneva (Switzerland)
Publication Date:
Research Org.:
Texas A & M Univ., College Station, TX (United States). Cyclotron Institute
Sponsoring Org.:
USDOE Office of Science (SC)
OSTI Identifier:
1545974
Alternate Identifier(s):
OSTI ID: 1545934
Grant/Contract Number:  
FG02-93ER40773
Resource Type:
Accepted Manuscript
Journal Name:
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Additional Journal Information:
Journal Volume: 943; Journal Issue: C; Journal ID: ISSN 0168-9002
Publisher:
Elsevier
Country of Publication:
United States
Language:
English
Subject:
73 NUCLEAR PHYSICS AND RADIATION PHYSICS; Micro pattern gas amplifier detector; Micromegas; Ionization chamber; Particle identification

Citation Formats

Spiridon, A., Pollacco, E., Saastamoinen, A., Dag, M., Roeder, B., Tribble, R. E., Trache, L., Pascovici, G., Mehl, B., and de Oliveira, R. A study in using MICROMEGAS to improve particle identification with the TAMU-MDM focal plane detector. United States: N. p., 2019. Web. doi:10.1016/j.nima.2019.162461.
Spiridon, A., Pollacco, E., Saastamoinen, A., Dag, M., Roeder, B., Tribble, R. E., Trache, L., Pascovici, G., Mehl, B., & de Oliveira, R. A study in using MICROMEGAS to improve particle identification with the TAMU-MDM focal plane detector. United States. https://doi.org/10.1016/j.nima.2019.162461
Spiridon, A., Pollacco, E., Saastamoinen, A., Dag, M., Roeder, B., Tribble, R. E., Trache, L., Pascovici, G., Mehl, B., and de Oliveira, R. Tue . "A study in using MICROMEGAS to improve particle identification with the TAMU-MDM focal plane detector". United States. https://doi.org/10.1016/j.nima.2019.162461. https://www.osti.gov/servlets/purl/1545974.
@article{osti_1545974,
title = {A study in using MICROMEGAS to improve particle identification with the TAMU-MDM focal plane detector},
author = {Spiridon, A. and Pollacco, E. and Saastamoinen, A. and Dag, M. and Roeder, B. and Tribble, R. E. and Trache, L. and Pascovici, G. and Mehl, B. and de Oliveira, R.},
abstractNote = {A MICROMEGAS detection amplifier has been incorporated into the design of the TAMU-MDM focal plane detector with the purpose of improving the energy resolution and thus, the particle identification. Furthermore, beam tests showed a factor of 2 improvement over the original design, from 10%–12% to 4%–6%, for ions with A ≤ 40 at E/A ~ 10–20 MeV.},
doi = {10.1016/j.nima.2019.162461},
journal = {Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment},
number = C,
volume = 943,
place = {United States},
year = {Tue Jul 30 00:00:00 EDT 2019},
month = {Tue Jul 30 00:00:00 EDT 2019}
}

Journal Article:

Citation Metrics:
Cited by: 6 works
Citation information provided by
Web of Science

Figures / Tables:

Figure 1 Figure 1: 2-D histogram measured using AstroBox showing the energy losses of a 23Al beam and its contaminants. The plot gives energy loss in the central pad (Y axis) versus the energy loss detected by one of the outer pads (X axis). The insert represents a Y-axis projection of themore » 23Al data giving the energy resolution.« less

Save / Share:

Works referenced in this record:

The oxford MDM-2 magnetic spectrometer
journal, May 1986

  • Pringle, D. M.; Catford, W. N.; Winfield, J. S.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 245, Issue 2-3
  • DOI: 10.1016/0168-9002(86)91256-8

Focal plane detector for the Oxford MDM-2 spectrometer
journal, October 1986

  • Winfield, J. S.; Pringle, D. M.; Catford, W. N.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 251, Issue 2
  • DOI: 10.1016/0168-9002(86)90794-1

Response of a resistive wire detector to 240 MeV alpha particles
journal, July 1995

  • Youngblood, D. H.; Lui, Y. -W.; Clark, H. L.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 361, Issue 3
  • DOI: 10.1016/0168-9002(95)00212-X

Optical model potentials involving loosely bound p -shell nuclei around 10 MeV/nucleon
journal, January 2000


Asymptotic normalization coefficients for 10 B 9 Be + p
journal, September 1997

  • Mukhamedzhanov, A. M.; Clark, H. L.; Gagliardi, C. A.
  • Physical Review C, Vol. 56, Issue 3
  • DOI: 10.1103/PhysRevC.56.1302

Asymptotic normalization coefficients for 8 B 7 Be + p from a study of 8 Li 7 Li + n
journal, June 2003


AstroBox: A novel detection system for very low-energy protons from β-delayed proton decay
journal, September 2013

  • Pollacco, E.; Trache, L.; Simmons, E.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 723
  • DOI: 10.1016/j.nima.2013.04.084

MICROMEGAS: a high-granularity position-sensitive gaseous detector for high particle-flux environments
journal, June 1996

  • Giomataris, Y.; Rebourgeard, Ph.; Robert, J. P.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 376, Issue 1
  • DOI: 10.1016/0168-9002(96)00175-1

Upgrade of the TAMU MDM-focal plane detector with MicroMegas technology
journal, June 2016

  • Spiridon, A.; Pollacco, E.; Roeder, B. T.
  • Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, Vol. 376
  • DOI: 10.1016/j.nimb.2016.02.011

SRIM – The stopping and range of ions in matter (2010)
journal, June 2010

  • Ziegler, James F.; Ziegler, M. D.; Biersack, J. P.
  • Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, Vol. 268, Issue 11-12
  • DOI: 10.1016/j.nimb.2010.02.091