DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: The Mu2e undoped CsI crystal calorimeter

Abstract

We present the Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystals and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Lastly, although the readout electronics were not final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.

Authors:
; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; more »; ; ; ; ; ; ; ; ; ; ; ; ; ; ; « less
Publication Date:
Research Org.:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Sponsoring Org.:
USDOE Office of Science (SC), High Energy Physics (HEP)
Contributing Org.:
Mu2e Collaboration
OSTI Identifier:
1420908
Report Number(s):
FERMILAB-CONF-18-007-E; arXiv:1801.02237
Journal ID: ISSN 1748-0221; 1646740; TRN: US1801506
Grant/Contract Number:  
AC02-07CH11359
Resource Type:
Accepted Manuscript
Journal Name:
Journal of Instrumentation
Additional Journal Information:
Journal Volume: 13; Journal Issue: 2; Conference: International Conference on Calorimetry for the High Energy Frontier, Lyon, France, 10/02-10/06/2017; Journal ID: ISSN 1748-0221
Publisher:
Institute of Physics (IOP)
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY

Citation Formats

Atanov, N., Baranov, V., Budagov, J., Cervelli, F., Colao, F., Cordelli, M., Corradi, G., Davydov, Y. I., Falco, S. Di, Diociaiuti, E., Donati, S., Donghia, R., Echenard, B., Giovannella, S., Glagolev, V., Grancagnolo, F., Happacher, F., Hitlin, D. G., Martini, M., Miscetti, S., Miyashita, T., Morescalchi, L., Murat, P., Pedreschi, E., Pezzullo, G., Porter, F., Raffaelli, F., Ricci, M., Saputi, A., Sarra, I., Spinella, F., Tassielli, G., Tereshchenko, V., Usubov, Z., and Zhu, R. Y. The Mu2e undoped CsI crystal calorimeter. United States: N. p., 2018. Web. doi:10.1088/1748-0221/13/02/C02037.
Atanov, N., Baranov, V., Budagov, J., Cervelli, F., Colao, F., Cordelli, M., Corradi, G., Davydov, Y. I., Falco, S. Di, Diociaiuti, E., Donati, S., Donghia, R., Echenard, B., Giovannella, S., Glagolev, V., Grancagnolo, F., Happacher, F., Hitlin, D. G., Martini, M., Miscetti, S., Miyashita, T., Morescalchi, L., Murat, P., Pedreschi, E., Pezzullo, G., Porter, F., Raffaelli, F., Ricci, M., Saputi, A., Sarra, I., Spinella, F., Tassielli, G., Tereshchenko, V., Usubov, Z., & Zhu, R. Y. The Mu2e undoped CsI crystal calorimeter. United States. https://doi.org/10.1088/1748-0221/13/02/C02037
Atanov, N., Baranov, V., Budagov, J., Cervelli, F., Colao, F., Cordelli, M., Corradi, G., Davydov, Y. I., Falco, S. Di, Diociaiuti, E., Donati, S., Donghia, R., Echenard, B., Giovannella, S., Glagolev, V., Grancagnolo, F., Happacher, F., Hitlin, D. G., Martini, M., Miscetti, S., Miyashita, T., Morescalchi, L., Murat, P., Pedreschi, E., Pezzullo, G., Porter, F., Raffaelli, F., Ricci, M., Saputi, A., Sarra, I., Spinella, F., Tassielli, G., Tereshchenko, V., Usubov, Z., and Zhu, R. Y. Thu . "The Mu2e undoped CsI crystal calorimeter". United States. https://doi.org/10.1088/1748-0221/13/02/C02037. https://www.osti.gov/servlets/purl/1420908.
@article{osti_1420908,
title = {The Mu2e undoped CsI crystal calorimeter},
author = {Atanov, N. and Baranov, V. and Budagov, J. and Cervelli, F. and Colao, F. and Cordelli, M. and Corradi, G. and Davydov, Y. I. and Falco, S. Di and Diociaiuti, E. and Donati, S. and Donghia, R. and Echenard, B. and Giovannella, S. and Glagolev, V. and Grancagnolo, F. and Happacher, F. and Hitlin, D. G. and Martini, M. and Miscetti, S. and Miyashita, T. and Morescalchi, L. and Murat, P. and Pedreschi, E. and Pezzullo, G. and Porter, F. and Raffaelli, F. and Ricci, M. and Saputi, A. and Sarra, I. and Spinella, F. and Tassielli, G. and Tereshchenko, V. and Usubov, Z. and Zhu, R. Y.},
abstractNote = {We present the Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystals and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Lastly, although the readout electronics were not final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.},
doi = {10.1088/1748-0221/13/02/C02037},
journal = {Journal of Instrumentation},
number = 2,
volume = 13,
place = {United States},
year = {Thu Feb 22 00:00:00 EST 2018},
month = {Thu Feb 22 00:00:00 EST 2018}
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record

Citation Metrics:
Cited by: 6 works
Citation information provided by
Web of Science

Figures / Tables:

Figure 1 Figure 1: The Mu2e experiment.

Save / Share:

Works referenced in this record:

A search for μ-e conversion in muonic gold
journal, May 2006


Works referencing / citing this record:

The Mu2e Experiment
journal, January 2019


Figures/Tables have been extracted from DOE-funded journal article accepted manuscripts.