DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: LYSO based precision timing calorimeters

Abstract

In this report we outline the study of the development of calorimeter detectors using bright scintillating crystals. We discuss how timing information with a precision of a few tens of pico seconds and below can significantly improve the reconstruction of the physics events under challenging high pileup conditions to be faced at the High-Luminosity LHC or a future hadron collider. The particular challenge in measuring the time of arrival of a high energy photon lies in the stochastic component of the distance of initial conversion and the size of the electromagnetic shower. We present studies and measurements from test beams for calorimeter based timing measurements to explore the ultimate timing precision achievable for high energy photons of 10 GeV and above. We focus on techniques to measure the timing with a high precision in association with the energy of the photon. We present test-beam studies and results on the timing performance and characterization of the time resolution of LYSO-based calorimeters. We demonstrate time resolution of 30 ps is achievable for a particular design.

Authors:
 [1];  [1];  [2];  [1];  [1];  [1];  [1];  [1];  [1];  [3]
  1. California Inst. of Technology (CalTech), Pasadena, CA (United States)
  2. Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
  3. Sharif Univ., Tehran (Iran)
Publication Date:
Research Org.:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Sponsoring Org.:
USDOE Office of Science (SC), High Energy Physics (HEP)
OSTI Identifier:
1413093
Report Number(s):
FERMILAB-CONF-17-574-E
Journal ID: ISSN 1742-6588; 1639976; TRN: US1800412
Grant/Contract Number:  
AC02-07CH11359
Resource Type:
Accepted Manuscript
Journal Name:
Journal of Physics. Conference Series
Additional Journal Information:
Journal Volume: 928; Journal Issue: 1; Journal ID: ISSN 1742-6588
Publisher:
IOP Publishing
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY

Citation Formats

Bornheim, A., Apresyan, A., Ronzhin, A., Xie, S., Duarte, J., Spiropulu, M., Trevor, J., Anderson, D., Pena, C., and Hassanshahi, M. H.. LYSO based precision timing calorimeters. United States: N. p., 2017. Web. doi:10.1088/1742-6596/928/1/012023.
Bornheim, A., Apresyan, A., Ronzhin, A., Xie, S., Duarte, J., Spiropulu, M., Trevor, J., Anderson, D., Pena, C., & Hassanshahi, M. H.. LYSO based precision timing calorimeters. United States. https://doi.org/10.1088/1742-6596/928/1/012023
Bornheim, A., Apresyan, A., Ronzhin, A., Xie, S., Duarte, J., Spiropulu, M., Trevor, J., Anderson, D., Pena, C., and Hassanshahi, M. H.. Wed . "LYSO based precision timing calorimeters". United States. https://doi.org/10.1088/1742-6596/928/1/012023. https://www.osti.gov/servlets/purl/1413093.
@article{osti_1413093,
title = {LYSO based precision timing calorimeters},
author = {Bornheim, A. and Apresyan, A. and Ronzhin, A. and Xie, S. and Duarte, J. and Spiropulu, M. and Trevor, J. and Anderson, D. and Pena, C. and Hassanshahi, M. H.},
abstractNote = {In this report we outline the study of the development of calorimeter detectors using bright scintillating crystals. We discuss how timing information with a precision of a few tens of pico seconds and below can significantly improve the reconstruction of the physics events under challenging high pileup conditions to be faced at the High-Luminosity LHC or a future hadron collider. The particular challenge in measuring the time of arrival of a high energy photon lies in the stochastic component of the distance of initial conversion and the size of the electromagnetic shower. We present studies and measurements from test beams for calorimeter based timing measurements to explore the ultimate timing precision achievable for high energy photons of 10 GeV and above. We focus on techniques to measure the timing with a high precision in association with the energy of the photon. We present test-beam studies and results on the timing performance and characterization of the time resolution of LYSO-based calorimeters. We demonstrate time resolution of 30 ps is achievable for a particular design.},
doi = {10.1088/1742-6596/928/1/012023},
journal = {Journal of Physics. Conference Series},
number = 1,
volume = 928,
place = {United States},
year = {2017},
month = {11}
}