skip to main content

DOE PAGESDOE PAGES

This content will become publicly available on October 19, 2018

Title: Interrupting an Imminent Body Current Fault and Restoring Full Power in Milliseconds on a DIII-D National Fusion Facility Gyrotron

The ECH Group at DIII-D has installed in-house engineered, FPGA-based, high voltage reference waveform generators on its gyrotron control systems to enhance the capabilities of the systems and replace obsolete equipment. The new hardware, named D-Wavegen, outputs 16-bit signals every microsecond and can respond to events and anomalies in real-time. These generators have been reliably pausing gyrotron rf output during periods of DIII-D plasma density that exceed the fault density trip level and restarting the rf output if the density falls below the trip level. While tightly monitoring gyrotron body current and internal pressure, D-Wavegen has also been reliably restarting, in a little over 10ms, gyrotrons that spontaneously ceased rf generation.
Authors:
ORCiD logo [1] ;  [1] ;  [1] ;  [1] ;  [1] ;  [1] ;  [1]
  1. General Atomics, San Diego, CA (United States)
Publication Date:
Grant/Contract Number:
FC02-04ER54698
Type:
Accepted Manuscript
Journal Name:
Fusion Science and Technology
Additional Journal Information:
Journal Volume: 73; Journal Issue: 1; Journal ID: ISSN 1536-1055
Publisher:
American Nuclear Society
Research Org:
General Atomics, San Diego, CA (United States)
Sponsoring Org:
USDOE Office of Science (SC), Fusion Energy Sciences (FES) (SC-24)
Country of Publication:
United States
Language:
English
Subject:
70 PLASMA PHYSICS AND FUSION TECHNOLOGY; gyrotron fault restart; body current fault; gyrotron interlock restart
OSTI Identifier:
1411886