skip to main content

DOE PAGESDOE PAGES

Title: Experimental calibration procedures for rotating Lorentz-force flowmeters

Rotating Lorentz-force flowmeters are a novel and useful technology with a range of applications in a variety of different industries. However, calibrating these flowmeters can be challenging, time-consuming, and expensive. In this paper, simple calibration procedures for rotating Lorentz-force flowmeters are presented. These procedures eliminate the need for expensive equipment, numerical modeling, redundant flowmeters, and system down-time. Finally, the calibration processes are explained in a step-by-step manner and compared to experimental results.
Authors:
 [1] ;  [1] ;  [1] ;  [1]
  1. Princeton Univ., Princeton, NJ (United States)
Publication Date:
Grant/Contract Number:
AC02-09CH11466
Type:
Accepted Manuscript
Journal Name:
Measurement Science and Technology
Additional Journal Information:
Journal Volume: 28; Journal Issue: 8; Journal ID: ISSN 0957-0233
Publisher:
IOP Publishing
Research Org:
Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)
Sponsoring Org:
USDOE
Country of Publication:
United States
Language:
English
Subject:
47 OTHER INSTRUMENTATION; liquid metals; flowmeter; calibration; rotating; Lorentz force
OSTI Identifier:
1373697

Hvasta, M. G., Slighton, N. T., Kolemen, E., and Fisher, A. E.. Experimental calibration procedures for rotating Lorentz-force flowmeters. United States: N. p., Web. doi:10.1088/1361-6501/aa781b.
Hvasta, M. G., Slighton, N. T., Kolemen, E., & Fisher, A. E.. Experimental calibration procedures for rotating Lorentz-force flowmeters. United States. doi:10.1088/1361-6501/aa781b.
Hvasta, M. G., Slighton, N. T., Kolemen, E., and Fisher, A. E.. 2017. "Experimental calibration procedures for rotating Lorentz-force flowmeters". United States. doi:10.1088/1361-6501/aa781b. https://www.osti.gov/servlets/purl/1373697.
@article{osti_1373697,
title = {Experimental calibration procedures for rotating Lorentz-force flowmeters},
author = {Hvasta, M. G. and Slighton, N. T. and Kolemen, E. and Fisher, A. E.},
abstractNote = {Rotating Lorentz-force flowmeters are a novel and useful technology with a range of applications in a variety of different industries. However, calibrating these flowmeters can be challenging, time-consuming, and expensive. In this paper, simple calibration procedures for rotating Lorentz-force flowmeters are presented. These procedures eliminate the need for expensive equipment, numerical modeling, redundant flowmeters, and system down-time. Finally, the calibration processes are explained in a step-by-step manner and compared to experimental results.},
doi = {10.1088/1361-6501/aa781b},
journal = {Measurement Science and Technology},
number = 8,
volume = 28,
place = {United States},
year = {2017},
month = {7}
}