Title: Fluorescence imaging of ion distributions in an inductively coupled plasma with laser ablation sample introduction

Authors:
; ORCiD logo; ; ORCiD logo
Publication Date:
Sponsoring Org.:
USDOE
OSTI Identifier:
1360855
Resource Type:
Publisher's Accepted Manuscript
Journal Name:
Spectrochimica Acta. Part B, Atomic Spectroscopy
Additional Journal Information:
Journal Name: Spectrochimica Acta. Part B, Atomic Spectroscopy Journal Volume: 105 Journal Issue: C; Journal ID: ISSN 0584-8547
Publisher:
Elsevier
Country of Publication:
United Kingdom
Language:
English

Citation Formats

Moses, Lance M., Ellis, Wade C., Jones, Derick D., and Farnsworth, Paul B. Fluorescence imaging of ion distributions in an inductively coupled plasma with laser ablation sample introduction. United Kingdom: N. p., 2015. Web. doi:10.1016/j.sab.2014.08.002.
Moses, Lance M., Ellis, Wade C., Jones, Derick D., & Farnsworth, Paul B. Fluorescence imaging of ion distributions in an inductively coupled plasma with laser ablation sample introduction. United Kingdom. https://doi.org/10.1016/j.sab.2014.08.002
Moses, Lance M., Ellis, Wade C., Jones, Derick D., and Farnsworth, Paul B. Sun . "Fluorescence imaging of ion distributions in an inductively coupled plasma with laser ablation sample introduction". United Kingdom. https://doi.org/10.1016/j.sab.2014.08.002.
@article{osti_1360855,
title = {Fluorescence imaging of ion distributions in an inductively coupled plasma with laser ablation sample introduction},
author = {Moses, Lance M. and Ellis, Wade C. and Jones, Derick D. and Farnsworth, Paul B.},
abstractNote = {},
doi = {10.1016/j.sab.2014.08.002},
journal = {Spectrochimica Acta. Part B, Atomic Spectroscopy},
number = C,
volume = 105,
place = {United Kingdom},
year = {Sun Mar 01 00:00:00 EST 2015},
month = {Sun Mar 01 00:00:00 EST 2015}
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record
https://doi.org/10.1016/j.sab.2014.08.002

Citation Metrics:
Cited by: 4 works
Citation information provided by
Web of Science

Save / Share:

Works referenced in this record:

Computer simulations of sample chambers for laser ablation–inductively coupled plasma spectrometry
journal, February 2007

  • Bleiner, Davide; Bogaerts, Annemie
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 62, Issue 2
  • DOI: 10.1016/j.sab.2007.02.010

Laser ablation-ICP-MS: particle size dependent elemental composition studies on filter-collected and online measured aerosols from glass
journal, January 2004

  • Kuhn, Hans-Rudolf; Günther, Detlef
  • J. Anal. At. Spectrom., Vol. 19, Issue 9
  • DOI: 10.1039/B404729J

Expansion phenomena of aerosols generated by laser ablation under helium and argon atmosphere
journal, January 2008

  • Koch, J.; Wälle, M.; Schlamp, S.
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 63, Issue 1
  • DOI: 10.1016/j.sab.2007.11.013

Vaporization and ionization of laser ablation generated aerosols in an inductively coupled plasma mass spectrometer—implications from ion distribution maps
journal, January 2006

  • Wang, Zhongke; Hattendorf, Bodo; Günther, Detlef
  • J. Anal. At. Spectrom., Vol. 21, Issue 11
  • DOI: 10.1039/B607469N

Optical Measurements of Ion Trajectories through the Vacuum Interface of an Inductively Coupled Plasma Mass Spectrometer
journal, April 2004

  • Macedone, Jeffrey H.; Mills, Andrew A.; Farnsworth, Paul B.
  • Applied Spectroscopy, Vol. 58, Issue 4
  • DOI: 10.1366/000370204773580329

High resolution imaging of barium ions and atoms near the sampling cone of an inductively coupled plasma mass spectrometer
journal, September 2006

  • Mills, Andrew A.; Macedone, Jeffrey H.; Farnsworth, Paul B.
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 61, Issue 9
  • DOI: 10.1016/j.sab.2006.10.006

Multi-element model for the simulation of inductively coupled plasmas: Effects of helium addition to the central gas stream
journal, June 2011

  • Lindner, Helmut; Bogaerts, Annemie
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 66, Issue 6
  • DOI: 10.1016/j.sab.2011.04.007

Characterization of the supersonic expansion in the vacuum interface of an inductively coupled plasma mass spectrometer by high-resolution diode laser spectroscopy
journal, June 2006

  • Radicic, W. Neil; Olsen, Jordan B.; Nielson, Rebecca V.
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 61, Issue 6
  • DOI: 10.1016/j.sab.2005.09.004

Changes in plasma composition during the expansion into the first vacuum stage of an inductively coupled plasma mass spectrometer
journal, September 2006

  • Macedone, Jeffrey H.; Farnsworth, Paul B.
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 61, Issue 9
  • DOI: 10.1016/j.sab.2006.09.004

Analysis of Laser-Produced Aerosols by Inductively Coupled Plasma Mass Spectrometry: Transport Phenomena and Elemental Fractionation
journal, January 2008

  • Koch, J.; Wälle, M.; Dietiker, R.
  • Analytical Chemistry, Vol. 80, Issue 4
  • DOI: 10.1021/ac071450d

Detection efficiencies in nano- and femtosecond laser ablation inductively coupled plasma mass spectrometry
journal, January 2009

  • Wälle, M.; Koch, J.; Flamigni, L.
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 64, Issue 1
  • DOI: 10.1016/j.sab.2008.10.021

A multiphase model for pulsed ns-laser ablation of copper in an ambient gas
conference, January 2012

  • Autrique, D.; Chen, Z.; Alexiades, V.
  • INTERNATIONAL SYMPOSIUM ON HIGH POWER LASER ABLATION 2012, AIP Conference Proceedings
  • DOI: 10.1063/1.4739917

Laser-generated aerosols in laser ablation for inductively coupled plasma spectrometry
journal, March 2006


Simulation and Experimental Studies on Plasma Temperature, Flow Velocity, and Injector Diameter Effects for an Inductively Coupled Plasma
journal, November 2011

  • Lindner, Helmut; Murtazin, Ayrat; Groh, Sebastian
  • Analytical Chemistry, Vol. 83, Issue 24
  • DOI: 10.1021/ac201699q

Influence of physical properties and chemical composition of sample on formation of aerosol particles generated by nanosecond laser ablation at 213 nm
journal, January 2010

  • Holá, Markéta; Konečná, Veronika; Mikuška, Pavel
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 65, Issue 1
  • DOI: 10.1016/j.sab.2009.11.003

Evidence supporting the occurrence of Coulomb fission during conventional sample introduction in inductively coupled plasma mass spectrometry
journal, January 2009

  • Fraser, Matheson M.; Beauchemin, Diane
  • Journal of Analytical Atomic Spectrometry, Vol. 24, Issue 4
  • DOI: 10.1039/b819816k

Role of laser-induced melting and vaporization of metals during ICP-MS and LIBS analysis, investigated with computer simulations and experiments
journal, January 2006

  • Bleiner, Davide; Chen, Zhaoyang; Autrique, David
  • Journal of Analytical Atomic Spectrometry, Vol. 21, Issue 9
  • DOI: 10.1039/b602800d

Factors affecting analyte transport through the sampling orifice of an inductively coupled plasma mass spectrometer
journal, September 2001

  • Macedone, Jeffrey H.; Gammon, Dennis J.; Farnsworth, Paul B.
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 56, Issue 9
  • DOI: 10.1016/S0584-8547(01)00262-2

The agglomeration state of nanosecond laser-generated aerosol particles entering the ICP
journal, August 2005

  • Kuhn, Hans-Rudolf; Günther, Detlef
  • Analytical and Bioanalytical Chemistry, Vol. 383, Issue 3
  • DOI: 10.1007/s00216-005-0021-x

Study by focused shadowgraphy of the effect of laser irradiance on laser-induced plasma formation and ablation rate in various gases
journal, January 2009

  • Gravel, Jean-Francois Y.; Boudreau, Denis
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 64, Issue 1
  • DOI: 10.1016/j.sab.2008.10.037

Evaluation of space charge effects in the second vacuum stage of a commercial inductively coupled plasma mass spectrometer by planar laser-induced fluorescence imaging
journal, October 2012

  • Edmund, Alisa J.; Bergeson, Scott D.; Lyon, Mary
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 76
  • DOI: 10.1016/j.sab.2012.06.028

The effect of the sampling interface on spatial distributions of barium ions and atoms in an inductively coupled plasma ion source
journal, May 2009

  • Ma, H.; Taylor, N.; Farnsworth, P. B.
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 64, Issue 5
  • DOI: 10.1016/j.sab.2009.04.006

Considerations about the detection efficiency in inductively coupled plasma mass spectrometry
journal, October 2012


Analyte response in laser ablation inductively coupled plasma mass spectrometry
journal, May 2006

  • Wang, Zhongke; Hattendorf, Bodo; Günther, Detlef
  • Journal of the American Society for Mass Spectrometry, Vol. 17, Issue 5
  • DOI: 10.1016/j.jasms.2006.01.005

Design analysis of a laser ablation cell for inductively coupled plasma mass spectrometry by numerical simulation
journal, February 2008

  • Autrique, D.; Bogaerts, A.; Lindner, H.
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 63, Issue 2
  • DOI: 10.1016/j.sab.2007.11.032

Study of plasma parameters influencing fractionation in laser ablation-inductively coupled plasma-mass spectrometry
journal, December 2010


Analysis of brass and silicate glass by femtosecond laser ablation inductively coupled plasma mass spectrometry using liquid standard calibration
journal, January 2008

  • Wälle, M.; Koch, J.; Günther, D.
  • Journal of Analytical Atomic Spectrometry, Vol. 23, Issue 9
  • DOI: 10.1039/b803563f

Fundamental studies of mixed-gas inductively coupled plasmas
journal, October 1994

  • Sesi, Norman N.; Mackenzie, Amelia; Shanks, Kathryn E.
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 49, Issue 12-14
  • DOI: 10.1016/0584-8547(94)80108-8

Local effects of atomizing analyte droplets on the plasma parameters of the inductively coupled plasma
journal, March 2009

  • Groh, Sebastian; Garcia, Carmen C.; Murtazin, Ayrat
  • Spectrochimica Acta Part B: Atomic Spectroscopy, Vol. 64, Issue 3
  • DOI: 10.1016/j.sab.2009.02.008

Investigating the Fate of Individual Sample Droplets in Inductively Coupled Plasmas
journal, May 1997


Visualization, velocimetry, and mass spectrometric analysis of engineered and laser-produced particles passing through inductively coupled plasma sources
journal, January 2012

  • Flamigni, Luca; Koch, Joachim; Wiltsche, Helmar
  • Journal of Analytical Atomic Spectrometry, Vol. 27, Issue 4
  • DOI: 10.1039/c2ja10317f

Effects of Particle Size Distribution on Inductively Coupled Plasma Mass Spectrometry Signal Intensity during Laser Ablation of Glass Samples
journal, November 1999

  • Jeong, S. H.; Borisov, O. V.; Yoo, J. H.
  • Analytical Chemistry, Vol. 71, Issue 22
  • DOI: 10.1021/ac990455a

Characterization of the ion beam inside the skimmer cone of an inductively coupled plasma mass spectrometer by laser excited atomic and ionic fluorescence
journal, April 1999


Wavelength dependant ablation rates for metals and silicate glasses using homogenized laser beam profiles — implications for LA-ICP-MS
journal, October 2001


Metal particles produced by laser ablation for ICP–MS measurements
journal, September 2007


On-line additions of aqueous standards for calibration of laser ablation inductively coupled plasma mass spectrometry: theory and comparison of wet and dry plasma conditions
journal, January 2006

  • O? Connor, Ciaran; Sharp, Barry L.; Evans, Peter
  • Journal of Analytical Atomic Spectrometry, Vol. 21, Issue 6
  • DOI: 10.1039/b600916f

The effect of carrier gas humidity on the vaporization of laser-produced aerosols in inductively coupled plasmas
journal, January 2014

  • Flamigni, Luca; Koch, Joachim; Günther, Detlef
  • J. Anal. At. Spectrom., Vol. 29, Issue 2
  • DOI: 10.1039/C3JA50314C

Peer Reviewed: Laser Ablation-ICPMS
journal, August 2003

  • Hattendorf, Bodo; Latkoczy, Christopher; Günther, Detlef
  • Analytical Chemistry, Vol. 75, Issue 15
  • DOI: 10.1021/ac031283r

Glass particles produced by laser ablation for ICP-MS measurements
journal, September 2007


An improved model for nanosecond pulsed laser ablation of metals
journal, August 2013

  • Lutey, Adrian H. A.
  • Journal of Applied Physics, Vol. 114, Issue 8
  • DOI: 10.1063/1.4818513