DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Tests of cosmic ray radiography for power industry applications

Abstract

In this report, we assess muon multiple scattering tomography as a non-destructive inspection technique in several typical areas of interest to the nuclear power industry, including monitoring concrete degradation, gate valve conditions, and pipe wall thickness. This work is motivated by the need for imaging methods that do not require the licensing, training, and safety controls of x-rays, and by the need to be able to penetrate considerable overburden to examine internal details of components that are otherwise inaccessible, with minimum impact on industrial operations. In some instances, we find that muon tomography may be an attractive alternative to more typical measurements.

Authors:
; ; ; ; ; ; ; ;
Publication Date:
Research Org.:
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
1198598
Alternate Identifier(s):
OSTI ID: 1208850; OSTI ID: 1221413; OSTI ID: 1420678
Report Number(s):
LA-UR-15-22129
Journal ID: ISSN 2158-3226
Grant/Contract Number:  
Contract DE-AC5206NA25396; AC52-06NA25396
Resource Type:
Published Article
Journal Name:
AIP Advances
Additional Journal Information:
Journal Name: AIP Advances Journal Volume: 5 Journal Issue: 6; Journal ID: ISSN 2158-3226
Publisher:
American Institute of Physics
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; muons; cosmic rays; image sensors; tomography; image reconstruction

Citation Formats

Durham, J. M., Guardincerri, E., Morris, C. L., Bacon, J., Fabritius, J., Fellows, S., Poulson, D., Plaud-Ramos, K., and Renshaw, J. Tests of cosmic ray radiography for power industry applications. United States: N. p., 2015. Web. doi:10.1063/1.4922006.
Durham, J. M., Guardincerri, E., Morris, C. L., Bacon, J., Fabritius, J., Fellows, S., Poulson, D., Plaud-Ramos, K., & Renshaw, J. Tests of cosmic ray radiography for power industry applications. United States. https://doi.org/10.1063/1.4922006
Durham, J. M., Guardincerri, E., Morris, C. L., Bacon, J., Fabritius, J., Fellows, S., Poulson, D., Plaud-Ramos, K., and Renshaw, J. Mon . "Tests of cosmic ray radiography for power industry applications". United States. https://doi.org/10.1063/1.4922006.
@article{osti_1198598,
title = {Tests of cosmic ray radiography for power industry applications},
author = {Durham, J. M. and Guardincerri, E. and Morris, C. L. and Bacon, J. and Fabritius, J. and Fellows, S. and Poulson, D. and Plaud-Ramos, K. and Renshaw, J.},
abstractNote = {In this report, we assess muon multiple scattering tomography as a non-destructive inspection technique in several typical areas of interest to the nuclear power industry, including monitoring concrete degradation, gate valve conditions, and pipe wall thickness. This work is motivated by the need for imaging methods that do not require the licensing, training, and safety controls of x-rays, and by the need to be able to penetrate considerable overburden to examine internal details of components that are otherwise inaccessible, with minimum impact on industrial operations. In some instances, we find that muon tomography may be an attractive alternative to more typical measurements.},
doi = {10.1063/1.4922006},
journal = {AIP Advances},
number = 6,
volume = 5,
place = {United States},
year = {Mon Jun 01 00:00:00 EDT 2015},
month = {Mon Jun 01 00:00:00 EDT 2015}
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record
https://doi.org/10.1063/1.4922006

Citation Metrics:
Cited by: 13 works
Citation information provided by
Web of Science

Save / Share: