Title:
J CELL CONTINUOUS CALCINER DAMAGE (MAY 7-8, 1957)
Subject Terms:
EQUIPMENTREDOXUNH CONVERSION PROCESS
Document Location:
DOE Public Reading Room - Hanford Battelle P.O. Box 999 MS H2-53 Richland WA 99352 (509)372-7443
Publication Date:
1957 May 27
Declassification Status:
Declassified
Accession Number:
RL-1-365723
Document Number(s):
HW-50358
Originating Research Org.:
GE - HAPO
OpenNet Entry Date:
2004 Feb 24
OpenNet Modified Date:
2015 Aug 14
Description/Abstract:
ON MAY 7-8 ALL OF THE AGITATOR BLADES AND BLADE SUPPORTS IN J CALCINER WERE SO BADLY DAMAGED THAT REPLACEMENT WAS NECESSARY. CAUSE OF THE INITIAL FAILURE HAS NOT BEEN ESTABLISHED. THIS MEMO GIVES A BRIEF HISTORY OF J CALCINER OPERATION AND ALL OF THE INFORMATION WHICH HAS BEEN OBTAINED CONCERNING OPERATION OF J CALCINER DURING THE 12 HOUR PERIOD BEFORE SHUTDOWN.