Title:
TRANSISTORIZED RADIOLOGICAL SURVEY INSTRUMENTS
Subject Terms:
DESIGNRADIATION AND RADIATION PROTECTIONRADIATION DETECTION INSTRUMENTSTRASISTORS
Document Location:
DOE Public Reading Room - Hanford Battelle P.O. Box 999 MS H2-53 Richland WA 99352 (509)372-7443
Publication Date:
1956 Nov 28
Declassification Status:
Declassified
Accession Number:
RL-1-364770
Document Number(s):
HW-46793
Originating Research Org.:
GE - HAPO
OpenNet Entry Date:
2004 Feb 24
OpenNet Modified Date:
2015 Jul 31
Description/Abstract:
DESCRIBES STD COMPONENTS TO USE WITH PORTABLE SURVEY INSTRUMENTS FOR THE MEASUREMENT OF ALPHA, BETA, AND GAMMA CONTAMN AND NEUTRON FLUX. THESE INSTRUMENTS USE TRANSISTORS WITH VARIOUS DETECTORS PERTINENT TO THE PROBLEMS. TRANSISTOR CIRCUITRY IS USED TO OBTAIN SIZE AND WEIGHT REDN, EASE OF MAINTENANCE, AND LONG BATTERY LIFE. COUNT-RATE METER AND HIGH VOLTAGE SUPPLY CIRCUITS ARE STD.