Title:
FINAL REPORT - PRODUCTION TEST 105-606-A -- THE EFFECT OF MODERATOR TEMPERATURE ON CONTROL ROD STRENGTHS
Subject Terms:
100 AreasCONTROL ROD TEMPERATURESCONTROL RODSDR ReactorHANFORD PRODUCTION REACTORS CONTROLPT-105-606-AReactor Technology
Document Location:
DOE Public Reading Room - Hanford Battelle P.O. Box 999 MS H2-53 Richland WA 99352 (509)372-7443
Publication Date:
1955 Nov 21
Declassification Date:
1992 Sep 15
Declassification Status:
Declassified
Accession Number:
RL-1-362899
Document Number(s):
HW-39968
Originating Research Org.:
GE - HAPO
OpenNet Entry Date:
2004 Feb 24
OpenNet Modified Date:
2015 Jul 29
Description/Abstract:
INHOUR VALUE OF THE VSR'S IS SLIGHTLY GREATER IN THE 500 DEGREE GRAPHITE PILE THAN IN THE 100 DEGREE LATTICE. THE EFFECT WHICH DOES EXIST TENDS TO MAKE THE USE OF COLD PILE SAFETY SYSTEM CAPACITY VALUES CONSERVATIVE.