Document Details


PURL
Title:
C PILE TUBE PRESSURE MONITORING SYSTEM RELIABILITY
Author(s):
Subject Terms:
100 AreasC ReactorReactor Technology
Document Location:
DOE Public Reading Room - Hanford Battelle P.O. Box 999 MS H2-53 Richland WA 99352 (509)372-7443
Document Type:
REPORT
Publication Date:
1954 Oct 25
Declassification Date:
1996 Jul 01
Declassification Status:
Declassified
Document Pages:
6
Accession Number:
RL-1-360995
Document Number(s):
HW-33528
Originating Research Org.:
GE - HAPO
OpenNet Entry Date:
2004 Jan 09
OpenNet Modified Date:
2015 Aug 24
Description/Abstract:
DETAILED ANALYSIS OF THE TRIP CHECK FAILURES FOR JULY, AUGUST AND SEPTEMBER AND RECOMMENDATIONS TO HELP IMPROVE THE RELIABILITY OF THE PRESSURE MONITOR SYSTEM ARE PRESENTED. FAILURES ARE CLASSIFIES AS 1) PANELLIT GAGE COMPONENT FAILURES, 2) INSTRUMENT MAINTENANCE PROCEDURE ERRORS AND 3) PANELLIT SYSTEM FAILURES