Description/Abstract:
AIRBORNE MEASUREMENS OF THE ABSOLUTE VERTICAL ELECTRIC FIELD (E-FIELD) OF THE RADIATED ELECTROMAGNETIC PULSE WERE ATTEMPTED FOR SHOTS LITTLE FELLER II AND SMALL BOY. INSTRUMENTATION INCLUDED CALIBRATED VERTICA L WHIP ANTENNAS, WIDE-BAND MAGNETIC TAPE RECORDERS, AND PHOTOGRAPHS OF OSCILLOSCOPE TRACES. ONE INSTRUMENTED AIRCRAFT PARTICIPATED IN LITTL E FELLER II (C-131F); TWO AIRCRAFT PARTICIPATED IN SMALL BOY (A C-131F AND AN A-3A). NO DETECTABLE SIGNALS WERE RECORDED FOR EITHER EVENT. IT IS CONCLUDED THAT THE VERTICAL E-FIELD INTENSITIES ENCOUNTERED WER E BELOW THE CALIBRATED LEVELS OF THE INSTRUMENTATION OF THE METHOD OF INSTRUMENTATION AND CALIBRATION WAS INADEQUATE FOR NONREPETITIVE PULSE SIGNALS.