National Library of Energy BETA

Sample records for units browns ferry

  1. ATWS at Browns Ferry Unit One - accident sequence analysis

    SciTech Connect

    Harrington, R.M.; Hodge, S.A.

    1984-07-01

    This study describes the predicted response of Unit One at the Browns Ferry Nuclear Plant to a postulated complete failure to scram following a transient occurrence that has caused closure of all Main Steam Isolation Valves (MSIVs). This hypothetical event constitutes the most severe example of the type of accident classified as Anticipated Transient Without Scram (ATWS). Without the automatic control rod insertion provided by scram, the void coefficient of reactivity and the mechanisms by which voids are formed in the moderator/coolant play a dominant role in the progression of the accident. Actions taken by the operator greatly influence the quantity of voids in the coolant and the effect is analyzed in this report. The progression of the accident sequence under existing and under recommended procedures is discussed. For the extremely unlikely cases in which equipment failure and wrongful operator actions might lead to severe core damage, the sequence of emergency action levels and the associated timing of events are presented.

  2. ATWS analysis for Browns Ferry Nuclear Plant Unit 1

    SciTech Connect

    Dallman, R.J.; Jouse, W.C.

    1985-01-01

    Analyses of postulated Anticipated Transients Without Scram (ATWS) were performed at the Idaho National Engineering Laboratory (INEL). The Browns Ferry Nuclear Plant Unit 1 (BFNP1) was selected as the subject of this work because of the cooperation of the Tennessee Valley Authority (TVA). The work is part of the Severe Accident Sequence Analysis (SASA) Program of the US Nuclear Regulatory Commission (NRC). A Main Steamline Isolation Valve (MSIV) closure served as the transient initiator for these analyses, which proceeded a complete failure to scram. Results from the analyses indicate that operator mitigative actions are required to prevent overpressurization of the primary containment. Uncertainties remain concerning the effectiveness of key mitigative actions. The effectiveness of level control as a power reduction procedure is limited. Power level resulting from level control only reduce the Pressure Suppression Pool (PSP) heatup rate from 6 to 4F/min.

  3. Alabama Nuclear Profile - Browns Ferry

    Energy Information Administration (EIA) (indexed site)

    Browns Ferry" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License expiration date" 1,"1,101","8,072",83.7,"BWR","application/vnd.ms-excel","application/vnd.ms-excel"

  4. Severe Accident Sequence Analysis Program: Anticipated transient without scram simulations for Browns Ferry Nuclear Plant Unit 1

    SciTech Connect

    Dallman, R J; Gottula, R C; Holcomb, E E; Jouse, W C; Wagoner, S R; Wheatley, P D

    1987-05-01

    An analysis of five anticipated transients without scram (ATWS) was conducted at the Idaho National Engineering Laboratory (INEL). The five detailed deterministic simulations of postulated ATWS sequences were initiated from a main steamline isolation valve (MSIV) closure. The subject of the analysis was the Browns Ferry Nuclear Plant Unit 1, a boiling water reactor (BWR) of the BWR/4 product line with a Mark I containment. The simulations yielded insights to the possible consequences resulting from a MSIV closure ATWS. An evaluation of the effects of plant safety systems and operator actions on accident progression and mitigation is presented.

  5. Applications of the RELAP5 code to the station blackout transients at the Browns Ferry Unit One Plant

    SciTech Connect

    Schultz, R.R.; Wagoner, S.R.

    1983-01-01

    As a part of the charter of the Severe Accident Sequence Analysis (SASA) Program, station blackout transients have been analyzed using a RELAP5 model of the Browns Ferry Unit 1 Plant. The task was conducted as a partial fulfillment of the needs of the US Nuclear Regulatory Commission in examining the Unresolved Safety Issue A-44: Station Blackout (1) the station blackout transients were examined (a) to define the equipment needed to maintain a well cooled core, (b) to determine when core uncovery would occur given equipment failure, and (c) to characterize the behavior of the vessel thermal-hydraulics during the station blackout transients (in part as the plant operator would see it). These items are discussed in the paper. Conclusions and observations specific to the station blackout are presented.

  6. RAMONA-3B application to Browns Ferry ATWS

    SciTech Connect

    Slovik, G.C.; Neymotin, L.; Cazzoli, E.; Saha, P.

    1984-01-01

    This paper discusses two preliminary MSIV clsoure ATWS calculations done using the RAMONA-3B code and the work being done to create the necessary cross section sets for the Browns Ferry Unit 1 reactor. The RAMONA-3B code employs a three-dimensional neutron kinetics model coupled with one-dimensional, four equation, nonhomogeneous, nonequilibrium thermal hydraulics. To be compatible with 3-D neutron kinetics, the code uses parallel coolant channels in the core. It also includes a boron transport model and all necessary BWR components such as jet pump, recirculation pump, steam separator, steamline with safety and relief valves, main steam isolation valve, turbine stop valve, and turbine bypass valve. A summary of RAMONA-3B neutron kinetics and thermal hydraulics models is presented in the Appendix.

  7. RAMONA-3B application to Browns Ferry ATWS

    SciTech Connect

    Slovik, G.C.; Neymotin, L.Y.; Saha, P.

    1985-01-01

    The Anticipated Transient Without Scram (ATWS) is known to be a dominant accident sequence for possible core melt in a Boiling Water Reactor (BWR). A recent Probabilistic Risk Assessment (PRA) analysis for the Browns Ferry nuclear power plant indicates that ATWS is the second most dominant transient for core melt in BWR/4 with Mark I containment. The most dominant sequence being the failure of long term decay heat removal function of the Residual Heat Removal (RHR) system. Of all the various ATWS scenarios, the Main Steam Isolation Valve (MSIV) closure ATWS sequence was chosen for present analysis because of its relatively high frequency of occurrence and its challenge to the residual heat removal system and containment integrity. The objective of this paper is to discuss four MSIV closure ATWS calculations using the RAMONA-3B code. The paper is a summary of a report being prepared for the USNRC Severe Accident Sequence Analysis (SASA) program which should be referred to for details. 10 refs., 20 figs., 3 tabs.

  8. Annual radiological environmental operating report: Browns Ferry Nuclear Plant, 1992. Operations Services/Technical Programs

    SciTech Connect

    Not Available

    1993-04-01

    This report describes the environmental radiological monitoring program conducted by TVA in the vicinity of Browns Ferry Nuclear Plant (BFN) in 1992. The program includes the collection of samples from the environment and the determination of the concentrations of radioactive materials in the samples. Samples are taken from stations in the general area of the plant and from areas not influenced by plant operations. Station locations are selected after careful consideration of the weather patterns and projected radiation doses to the various areas around the plant. Material sampled includes air, water, milk, foods, vegetation, soil, fish, sediment, and direct radiation levels. Results from stations near the plant are compared with concentrations from control stations and with preoperational measurements to determine potential impacts of plant operations. Small amounts of Co-60 and Cs-134 were found in sediment samples downstream from the plant. This activity in stream sediment would result in no measurable increase over background in the dose to the general public.

  9. 1,"Browns Ferry","Nuclear","Tennessee Valley Authority",3309.4

    Energy Information Administration (EIA) (indexed site)

    Alabama" ,"Plant","Primary energy source","Operating company","Net summer capacity (MW)" 1,"Browns Ferry","Nuclear","Tennessee Valley Authority",3309.4 2,"James H Miller Jr","Coal","Alabama Power Co",2725.9 3,"Barry","Coal","Alabama Power Co",2574.5 4,"E C Gaston","Coal","Alabama Power Co",1878 5,"H Allen Franklin Combined

  10. BWR ATWS simulations for Browns Ferry Nuclear Plant Unit 1

    SciTech Connect

    Dallman, R.J.

    1984-01-01

    Under auspices of the US Nuclear Regulatory Commission, simulations of anticipated transients without scram (ATWS) in a boiling water reactor are being performed. A methodology has been developed to study the ATWS, and deterministic analyses have been conducted. Results are presented for one of the most probable (albeit hypothetical) sequences leading to core and containment damage. Areas presenting calculational uncertainties are identified, and requirements for their resolution are proposed.

  11. Comparison of MELCOR and SCDAP/RELAP5 results for a low-pressure, short-term station blackout at Browns Ferry

    SciTech Connect

    Carbajo, J.J. [Oak Ridge National Lab., TN (United States)

    1995-12-31

    This study compares results obtained with two U.S. Nuclear Regulatory Commission (NRC)-sponsored codes, MELCOR version 1.8.3 (1.8PQ) and SCDAP/RELAP5 Mod3.1 release C, for the same transient - a low-pressure, short-term station blackout accident at the Browns Ferry nuclear plant. This work is part of MELCOR assessment activities to compare core damage progression calculations of MELCOR against SCDAP/RELAP5 since the two codes model core damage progression very differently.

  12. Alabama Nuclear Profile - Browns Ferry

    Energy Information Administration (EIA) (indexed site)

    expiration date" 1,"1,101","8,072",83.7,"BWR","applicationvnd.ms-excel","applicationvnd.ms-excel" 2,"1,104","8,843",91.5,"BWR","applicationvnd.ms-excel","application...

  13. Fermilab | Tritium at Fermilab | Ferry Creek Aerial View

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    Ferry Creek Aerial View Ferry Creek Aerial View

  14. Ferris State University | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Ferris State University Jump to: navigation, search Name: Ferris State University Place: Big Rapids, MI Website: www.ferrisstateuniversity.com References: Ferris State...

  15. Paynes Ferry Wind Farm | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Paynes Ferry Wind Farm Jump to: navigation, search Name Paynes Ferry Wind Farm Facility Paynes Ferry Wind Farm Sector Wind energy Facility Type Commercial Scale Wind Facility...

  16. Ferry Barge | Y-12 National Security Complex

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    Ferry Barge Ferry Barge Before the Manhattan Project, modern bridges were very far into the future for the Oak Ridge area. They came more quickly with the project...

  17. EERE Success Story-Washington: State Ferries Run Cleaner With...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    State Ferries Run Cleaner With Biodiesel EERE Success Story-Washington: State Ferries Run Cleaner With Biodiesel April 18, 2013 - 12:00am Addthis Washington State Ferries, owned ...

  18. EA-1973: Kootenai River Restoration at Bonners Ferry, Boundary...

    Energy Saver

    73: Kootenai River Restoration at Bonners Ferry, Boundary County, Idaho EA-1973: Kootenai River Restoration at Bonners Ferry, Boundary County, Idaho Summary Bonneville Power...

  19. Ferris, Texas: Energy Resources | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    is a stub. You can help OpenEI by expanding it. Ferris is a city in Dallas County and Ellis County, Texas. It falls under Texas's 30th congressional district and Texas's 6th...

  20. 1,"Browns Ferry","Nuclear","Tennessee Valley Authority",3309...

    Energy Information Administration (EIA) (indexed site)

    Co",2574.5 4,"E C Gaston","Coal","Alabama Power Co",1878 5,"H Allen Franklin Combined Cycle","Natural gas","Southern Power Co",1815 6,"Joseph M Farley","Nuclear","Alabama ...

  1. PUD No 1 of Ferry County | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Ferry County Jump to: navigation, search Name: PUD No 1 of Ferry County Place: Washington Phone Number: (509) 775-3325 Website: fcpud.com Outage Hotline: (509) 775-3849...

  2. Washington: State Ferries Run Cleaner With Biodiesel | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Addthis Related Articles Auto and passenger ferries operated by the Washington State ... SEP Success Story: Washington State Becomes Largest Public Consumer of Biodiesel Auto and ...

  3. Reduction of Emissions from a High Speed Ferry | Department of...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Reduction of Emissions from a High Speed Ferry 2003 DEER Conference Presentation: West Virginia University PDF icon 2003deerthompson.pdf More Documents & Publications Recent ...

  4. EERE Success Story—Washington: State Ferries Run Cleaner With Biodiesel

    Office of Energy Efficiency and Renewable Energy (EERE)

    Washington State Ferries now uses blended biodiesel to run its ferries, preventing the emission of more than 29,000 metric tons of carbon dioxide per year.

  5. City of Bonners Ferry, Idaho (Utility Company) | Open Energy...

    OpenEI (Open Energy Information) [EERE & EIA]

    index. Facebook: https:www.facebook.compagesCity-of-Bonners-Ferry-City-Hall-and-Utility-Offices Outage Hotline: 1-800-626-4950 References: EIA Form EIA-861 Final...

  6. Microsoft Word - BNRS_FERRY_3D_DEA_DRAFT_EA

    Energy Saver

    protecting spawning. Kootenai River Habitat Restoration at Bonners Ferry Project Draft Environmental Assessment 10 * Suggestion to create community support through a public...

  7. K. Aydin, V. E. Ferry, R. M. Briggs, and H. A. Atwater California...

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    Broadband polarization independent light absorption using ultrathin plasmonic super absorbers K. Aydin, V. E. Ferry, R. M. Briggs, and H. A. Atwater California Institute of...

  8. RAMONA-3B calculations for Browns Ferry ATWS (Anticipated Transient Without Scram) study

    SciTech Connect

    Saha, P; Slovik, G C; Neymotin, L Y

    1987-02-01

    Several aspects of the Anticipated Transient Without Scram (ATWS) initiated by an inadvertent closure of all Main Steam Isolation Valves (MSIV) in a typical BWR/4 are analyzed in the report. The analysis is performed using the Brookhaven National Laboratory code, RAMONA-3B, which employs a three-dimensional neutron kinetics model coupled with a parallel-channel thermal hydraulics in representing a Boiling Water Reactor (BWR) Core. Four different transient scenarios have been investigated: (a) downcomer water level and reactor pressure control, (b) manual control rod insertion transient, (c) high pressure boil-off, and (d) recirculation pump trip failure. Results of these calculations should provide better understanding of mitigative effects of operator actions during ATWS, thus helping in the development of adequate Emergency Procedure Guidelines (EPG) required for the BWR plant safety. A few unresolved questions subject to future investigations are also discussed.

  9. REDUCTION OF EMISSIONS FROM A HIGH SPEED FERRY

    SciTech Connect

    Thompson,G.; Gautam, M; Clark, N; Lyons, D; Carder, D; Riddle, W; Barnett, R; Rapp, B; George, S

    2003-08-24

    Emissions from marine vessels are being scrutinized as a major contributor to the total particulate matter (TPM), oxides of sulfur (SOx) and oxides of nitrogen (NOx) environmental loading. Fuel sulfur control is the key to SOx reduction. Significant reductions in the emissions from on-road vehicles have been achieved in the last decade and the emissions from these vehicles will be reduced by another order of magnitude in the next five years: these improvements have served to emphasize the need to reduce emissions from other mobile sources, including off road equipment, locomotives, and marine vessels. Diesel-powered vessels of interest include ocean going vessels with low- and medium-speed engines, as well as ferries with high speed engines, as discussed below. A recent study examined the use of intake water injection (WIS) and ultra low sulfur diesel (ULSD) to reduce the emissions from a high-speed passenger ferry in southern California. One of the four Detroit Diesel 12V92 two-stroke high speed engines that power the Waverider (operated by SCX, inc.) was instrumented to collect intake airflow, fuel flow, shaft torque, and shaft speed. Engine speed and shaft torque were uniquely linked for given vessel draft and prevailing wind and sea conditions. A raw exhaust gas sampling system was utilized to measure the concentration of NOx, carbon dioxide (CO2), and oxygen (O2) and a mini dilution tunnel sampling a slipstream from the raw exhaust was used to collect TPM on 70 mm filters. The emissions data were processed to yield brake-specific mass results. The system that was employed allowed for redundant data to be collected for quality assurance and quality control. To acquire the data, the Waverider was operated at five different steady state speeds. Three modes were in the open sea off Oceanside, CA, and idle and harbor modes were also used. Data have showed that the use of ULSD along with water injection (WIS) could significantly reduce the emissions of NOx and PM

  10. Brown Grease to Biodiesel Demonstration Project Report (Technical...

    Office of Scientific and Technical Information (OSTI)

    ... Country of Publication: United States Language: English Subject: 09 BIOMASS FUELS Brown Grease; Trap Waste; Biodiesel; Biofuel; Wastewater; Anaerobic Digestion Word Cloud More Like ...

  11. Fermilab Today | Brown University Profile

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    Brown University April 29, 2010 NAME: Brown University HOME TOWN: Providence, Rhode Island MASCOT: Bruno the Bear SCHOOL COLORS: Seal brown and cardinal red PARTICLE PHYSICS...

  12. A "Ferris Bueller Style" Look at Small Business Contracting at the

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Department of Energy | Department of Energy A "Ferris Bueller Style" Look at Small Business Contracting at the Department of Energy A "Ferris Bueller Style" Look at Small Business Contracting at the Department of Energy November 30, 2010 - 4:14pm Addthis Bill Valdez Bill Valdez Director of Workforce Management What does this mean for me? There are several program opportunities for small businesses within the Department of Energy. Some of the things on offer this year

  13. EA-1973: Kootenai River Restoration at Bonners Ferry, Boundary County, Idaho

    Energy.gov [DOE]

    Bonneville Power Administration (BPA) is preparing an EA to assess the potential environmental impacts of funding the Kootenai Tribe of Idaho to restore portions of the Kootenai River near the town of Bonners Ferry, Idaho. The proposed project involves installing structures on the river banks, excavating areas in the river to create deeper pools, and developing and enhancing islands that would be planted with native vegetation.

  14. EA-1901: Kootenai River White Sturgeon and Burbot Hatcheries Project, Bonners Ferry, Boundary County, Idaho

    Energy.gov [DOE]

    This EA evaluates the environmental impacts of a proposal for DOE’s Bonneville Power Administration to support the Kootenai Tribe of Idaho’s construction of a new hatchery on property owned by the Tribe at the confluence of the Moyie and Kootenai Rivers, approximately eight miles upstream from Bonners Ferry, Idaho. The proposed location of the new hatchery facility is currently the site of the Twin Rivers Canyon Resort.

  15. Application of the Ferris test methods for estimating hydraulic properties near a river boundary

    SciTech Connect

    Gilmore, T.J.; Spane, F.A. Jr.

    1993-10-01

    Standard hydraulic test methods, such as constant-rate pumping tests, may be impractical for characterizing hazardous waste sites located near fluctuating hydrologic boundaries such as rivers or oceans. An alternate approach for hydrologic characterization at these locations is to analyze the groundwater responses associated with river-stage or tidal fluctuations to aquifer properties (i.e., hydraulic diffusivity). Based on this approach, aquifer properties were determined for an area adjoining the Columbia River on the Hanford Site using two sinusoidal analysis techniques described in Ferris (1952, 1963). The first method uses the observed groundwater time-lag response, the second uses the amplitude ratio of well water level to river stage. Both techniques assume the river fluctuations can be approximated by a sinusoidal pattern. A range for hydraulic conductivity was calculated based on the hydraulic diffusivity estimates obtained from the methods together with the known aquifer thickness (50 ft) and assumed specific yield (0.1). The analysis methods produced two overlapping hydraulic conductivity ranges, with the Ferris time-lag analysis method forming the upper bound of the range, and the Ferris well water-level/river-stage amplitude ratio method forming the lower bound. Results from a nearby standard constant-rate discharge aquifer test were also examined for comparison. These results were within the upper bound of the hydraulic conductivity range.

  16. Conversation with Paul Brown | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Conversation with Paul Brown Jump to: navigation, search OpenEI Reference LibraryAdd to library Personal Communication: Conversation with Paul Brown Author Paul Brown Recipient...

  17. United States

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    George, Hartwell, Millers Ferry, West Point, Robert F. Henry, Carters and Richard B. Russell Projects and sold under appropriate contracts between the Government and the Customer. ...

  18. United States

    Office of Environmental Management (EM)

    J. Strom Thurmond, Walter F. George, Hartwell, Millers Ferry, West Point, Robert F. Henry, Carters and Richard B. Russell Projects and sold under appropriate contracts between...

  19. United States

    Office of Environmental Management (EM)

    power and accompanying energy generated at the Allatoona, Buford, J. Strom Thurmond, Walter F. George, Hartwell, Millers Ferry, West Point, Robert F. Henry, Carters and Richard...

  20. 3610 Collins Ferry Road, P.O. Box 880, Morgantown, WV 26507

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    610 Collins Ferry Road, P.O. Box 880, Morgantown, WV 26507 cliff.whyte@netl.doe.gov  Voice (304) 285-2098  Fax (304) 285-4403  www.netl.doe.gov A l b a ny, O R * M o rg a n tow n , W V * Pi t t s b u rg h , PA February 24, 2015 Dear Reader: The U.S. Department of Energy (DOE) has prepared a supplement analysis (SA) to the Texas Clean Energy Project (TCEP) Final Environmental Impact Statement (EIS). This document was prepared in accordance with the National Environmental Policy Act of

  1. NREL: Energy Analysis - Austin Brown

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    Austin Brown Photo of Austin Brown Austin Brown is currently away from the lab on a detail to the Office of Science and Technology Policy in the Executive Office of the President. Senior Analyst (Strategic Planning) On staff since 2010 Phone number: 202-488-2203 E-mail: austin.brown@nrel.gov Areas of expertise Crosscutting low-carbon strategies Clean transportation technologies and policies Primary research interests Clean energy research portfolio planning Energy and society Sustainable

  2. brown-98.pdf

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    High Resolution Validation in the Shortwave: ASTI/LBLRTM QME P. D. Brown, S. A. Clough, and E. J. Mlawer Atmospheric and Environmental Research, Inc. Cambridge, Massachusetts T. R. Shippert Pacific Northwest National Laboratory Richland, Washington F. J. Murcray Denver University Denver, Colorado Introduction To assess our modeling capability in the shortwave and to resolve issues including those described by Cess et al. (1995) and others (Li and Moreau 1996; Arking 1996), a Quality Measurement

  3. An Aqueous Redox Flow Battery Based on Neutral Alkali Metal Ferri/ferrocyanide and Polysulfide Electrolytes

    SciTech Connect

    Wei, Xiaoliang; Xia, Gordon; Kirby, Brent W.; Thomsen, Edwin C.; Li, Bin; Nie, Zimin; Graff, Gordon L.; Liu, Jun; Sprenkle, Vincent L.; Wang, Wei

    2015-11-13

    Aiming to explore low-cost redox flow battery systems, a novel iron-polysulfide (Fe/S) flow battery has been demonstrated in a laboratory cell. This system employs alkali metal ferri/ferrocyanide and alkali metal polysulfides as the redox electrolytes. When proper electrodes, such as pretreated graphite felts, are used, 78% energy efficiency and 99% columbic efficiency are achieved. The remarkable advantages of this system over current state-of-the-art redox flow batteries include: 1) less corrosive and relatively environmentally benign redox solutions used; 2) excellent energy and utilization efficiencies; 3) low cost for redox electrolytes and cell components. These attributes can lead to significantly reduced capital cost and make the Fe/S flow battery system a promising low-cost energy storage technology. The major drawbacks of the present cell design are relatively low power density and possible sulfur species crossover. Further work is underway to address these concerns.

  4. Brown County Wind | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Jump to: navigation, search Name Brown County Wind Facility Brown County Wind Sector Wind energy Facility Type Commercial Scale Wind Facility Status In Service Owner Adams Electric...

  5. Women @ Energy: Nancy Brown | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Nancy Brown Women @ Energy: Nancy Brown March 15, 2013 - 11:00am Addthis Dr. Nancy Jeanne Brown is a Senior Scientist at the Lawrence Berkeley National Laboratory. Dr. Nancy Jeanne Brown is a Senior Scientist at the Lawrence Berkeley National Laboratory. Check out other profiles in the Women @ Energy series and share your favorites on Pinterest. Dr. Nancy Jeanne Brown is a Senior Scientist at the Lawrence Berkeley National Laboratory. Her research interests are atmospheric science, chemical

  6. DOE/EIS-0283-S2

    Energy Saver

    ... and new information based in part on comments ... Extraction System Browns Ferry Browns Ferry Nuclear Plant BMP best management practice BWR boiling water reactor ...

  7. brown out | OpenEI Community

    OpenEI (Open Energy Information) [EERE & EIA]

    brown out Home Dc's picture Submitted by Dc(266) Contributor 31 October, 2014 - 10:58 What do you know about the grid? black out brown out bulk power system electricity grid future...

  8. DOE - Office of Legacy Management -- Brown University - Metcalf...

    Office of Legacy Management (LM)

    Brown University - Metcalf Research Lab - RI 01 FUSRAP Considered Sites Site: Brown University (Metcalf Research Lab.) (RI.01 ) Eliminated from further consideration under FUSRAP...

  9. CMI Education Partner: Brown University | Critical Materials Institute

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    Education Partner: Brown University Brown University offers courses in several areas: Engineering School Institute of Environment and Study Brown University: Engineering School http://www.brown.edu/academics/engineering/undergraduate-study/courses ENGN 0030 - Introduction to Engineering: An introduction to various engineering disciplines, thought processes, and issues. Topics include computing in engineering, engineering design, optimization, and estimation. Case studies in engineering are used

  10. Ukrainian mineral wax from brown coal

    SciTech Connect

    Shabad, T.

    1986-07-01

    An unusual mineral enterprise is the mineral wax plant of Semenovskoye in the Aleksandriya brown coal basin of the Ukraine. The only plant of its kind in the Soviet Union, it has been in operation since 1959, extracting mineral wax from the local bitumen-rich brown coal. The plant yields about 7.5 tons of mineral wax a day (about 2700 tons a year), for use in a variety of applications.

  11. Microsoft PowerPoint - 7 Kevin Brown

    Office of Environmental Management (EM)

    (CBP) Toolsets Kevin G. Brown Vanderbilt University and CRESP Cementitious Barriers Partnership Performance & Risk Assessment Community of Practice Technical Exchange Meeting December 11-12, 2014 Las Vegas NM Project Team Members Vanderbilt University & CRESP D. Kosson*, K.G. Brown*, S. Mahadevan, J. Branch, F. Sanchez Savannah River National Laboratory (SRNL) C. Langton*, G. Flach*, H. Burns*, R. Seitz, S. Marra Energy Research Centre of The Netherlands (ECN) & CRESP H. van der

  12. Brown Grease to Biodiesel Demonstration Project Report

    SciTech Connect

    San Francisco Public Utilities Commission; URS Corporation; Biofuels, Blackgold; Carollo Engineers

    2013-01-30

    program by other municipal agencies (as applicable). In order to accomplish the goals of the project, the following steps were performed: 1. Operation of a demonstration facility designed to receive 10,000 to 12,000 gallons of raw Trap Waste each day from private Trap Waste hauling companies. The demonstration facility was designed and built by Pacific Biodiesel Technologies (PBTech). The demonstration facility would also recover 300 gallons of Brown Grease per day from the raw Trap Waste. The recovered Brown Grease was expected to contain no more than 2% Moisture, Insolubles, and Unsaponifiables (MIU) combined. 2. Co-digestion of the side streams (generated during the recovery of 300 gallons of Brown Grease from the raw Trap Waste) with wastewater sludge in the WWTP's anaerobic digesters. The effects of the side streams on anaerobic digestion were quantified by comparison with baseline data. 3. Production of 240 gallons per day of ASTM D6751-S15 grade Biodiesel fuel via a Biodiesel conversion demonstration facility, with the use of recovered Brown Grease as a feedstock. The demonstration facility was designed and built by Blackgold Biofuels (BGB). Side streams from this process were also co-digested with wastewater sludge. Bench-scale anaerobic digestion testing was conducted on side streams from both demonstration facilities to determine potential toxicity and/or changes in biogas production in the WWTP anaerobic digester. While there is a lot of theoretical data available on the lab-scale production of Biodiesel from grease Trap Waste, this full-scale demonstration project was one of the first of its kind in the United States. The project's environmental impacts were expected to include: Reduction of greenhouse gas emissions by prevention of the release of methane at landfills. Although the combustion product of Biodiesel and Methane gas produced in the Anaerobic digester, Carbon Dioxide, is also a greenhouse gas; it is 20 times weaker for the same amount (per mole

  13. Movement of tagged dredged sand at thalweg disposal sites in the Upper Mississippi River. Volume 3. Additional results at Gordon's Ferry and Whitney Island sites

    SciTech Connect

    McCown, D.L.; Paddock, R.A.

    1985-04-01

    During routine channel maintenance, hydraulically dredged sand was tagged with sand coated with fluorescent dye before being deposited as a pile in the thalweg at three sites on the Upper Mississippi River. As discussed in the first two volumes of this report, bathymetry was measured and surface sediments were sampled to study changes in the topography of the disposal pile and the downstream movement of the tagged sand. At all three sites, topographic evidence of the pile disappeared after the first period of high river flow, which was followed by redevelopment of dunes in the disposal area. The tagged sand did not migrate into nearby border areas, backwaters, or sloughs, remaining in the main channel as it moved downstream. This volume presents the results of additional surveys at the Gordon's Ferry and Whitney Island sites. At Gordon's Ferry, 25 bottom cores were taken to examine the three-dimensional distribution of tagged sand in the bottom sediments. The core analyses indicated that much of the tagged sand had been incorporated into the dune structure and that it resided primarily in the crests of the dunes.

  14. FIA-12-0044- In the Matter of Cynthia Brown

    Energy.gov [DOE]

    Cynthia Brown filed an Appeal regarding a request filed under the Freedom of Information Act. In March 2012, Ms. Brown filed a request for records regarding her late mother.

  15. FIA-12-0009- In the Matter of Cynthia Brown

    Energy.gov [DOE]

    Cynthia Brown filed an Appeal regarding a request she filed under the Freedom of Information Act. In December 2011, Ms. Brown filed a request for records regarding her late mother.

  16. Brown-Atchison E C A Inc | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Brown-Atchison E C A Inc Jump to: navigation, search Name: Brown-Atchison E C A Inc Place: Kansas Phone Number: 785-486-2117 Website: baelectric.com Outage Hotline: After Hours:...

  17. Chelsea Brown | Center for Bio-Inspired Solar Fuel Production

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    Brown Graduate student Subtask 4 project: "Water Oxidation using Functionalized Porphyrin Chromophores and Iridium Catalyst"

  18. United States

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    ... Ellis (1993) collected fecal pellets from the roost of a maternity colony in North ... In summer, little brown bats roost under rocks, in piles of wood, and in trees (Fenton and ...

  19. Microsoft PowerPoint - 1 Kevin Brown

    Office of Environmental Management (EM)

    Program Update Interagency Steering Committee on Performance and Risk Assessment Community of Practice Annual Technical Exchange Meeting Richland, Washington December 15-16, 2015 Project Team Members Vanderbilt University & CRESP D. Kosson*, K.G. Brown*, A.C. Garrabrants, S. Mahadevan, J. Branch, F. Sanchez Savannah River National Laboratory (SRNL) C. Langton*; G. Flach*; H. Burns*; R. Seitz, S. Marra; F.G. Smith, III Energy Research Centre of The Netherlands (ECN) & CRESP H. van der

  20. Microsoft PowerPoint - 19 Kevin Brown

    Office of Environmental Management (EM)

    EVALUATING WASTEFORM LEACHING AND PERFORMANCE DOE COMMUNITY OF PRACTICE (P&RA COP) ANNUAL TECHNICAL EXCHANGE MEETING GERMANTOWN, MARYLAND OCTOBER 19 AND 20, 2016 Kevin G. Brown 1 , David S. Kosson 1 , Janelle Branch Lewis 1 , Andrew C. Garrabrants 1 , Hans van der Sloot 2 , Paul Seignette 3 , J.C.L Meeussen 4 1 Vanderbilt University 2 Hans van der Sloot Consultancy 3 Energy Research Center of the Netherlands 4 Nuclear Research Group (Netherlands) SUMMARY OF MAJOR ACTIVITIES * Experimental -

  1. Other United States Government Awards

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    us govt awards Other United States Government Awards As a Department of Energy (DOE) national laboratory, LLNL tracks achievements recognized by awards from the DOE. These awards span a wide range of accomplishments and include recognition of exemplary programmatic achievements. . Name Year Citation Dexter Lenoir, Rochelle Aguilar, Ramon Martinez, Erik Simmons, Chelle Blocker, Camerino Gutierrez, Joseph Chilton, Janet Cortez, Gary Brown, Judith Juarez, Sobhana Singh, Ronald Washington, Lorraine

  2. Baghouse Slipstream Testing at TXU's Big Brown Station

    SciTech Connect

    John Pavlish; Jason Laumb; Robert Jensen; Jeffery Thompson; Christopher Martin; Mark Musich; Brandon Pavlish; Stanley Miller; Lucinda Hamre

    2007-04-30

    Performing sorbent testing for mercury control at a large scale is a very expensive endeavor and requires months of planning and careful execution. Even with good planning, there are plant limitations on what operating/design parameters can be varied/tested and when. For parameters that cannot be feasibly tested at the full scale (lower/higher gas flow, different bag material, cleaning methods, sorbents, etc.), an alternative approach is used to perform tests on a slipstream unit using flue gas from the plant. The advantage that a slipstream unit provides is the flexibility to test multiple operating and design parameters and other possible technology options without risking major disruption to the operation of the power plant. Additionally, the results generated are expected to simulate full-scale conditions closely, since the flue gas used during the tests comes directly from the plant in question. The Energy & Environmental Research Center developed and constructed a mobile baghouse that allows for cost-effective testing of impacts related to variation in operating and design parameters, as well as other possible mercury control options. Multiple sorbents, air-to-cloth ratios, bag materials, and cleaning frequencies were evaluated while flue gas was extracted from Big Brown when it fired a 70% Texas lignite-30% Powder River Basin (PRB) blend and a 100% PRB coal.

  3. Browning: Email in Response to Smart Grid Request for Information |

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Department of Energy Browning: Email in Response to Smart Grid Request for Information Browning: Email in Response to Smart Grid Request for Information Email from Stephen Browning explaing the two attachments submitted in response to the Smart Grid Request for Information on Addressing Policy and Logistical Challenges. Smart Gird Policy Memo (15.63 KB) More Documents & Publications Power North America RFI Comments City Utilities of Springfield Missouri Comments on Smart Grid RFI:

  4. Senior Obama Administration Officials to Join Governor Brown...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Secretary Daniel Poneman will join California Governor Jerry Brown, Los Angeles Mayor Eric Garcetti and state, local and tribal leaders from across the country for a media...

  5. MEMORANDUM FROM: THOMAS E. BROWN, DIRECTOR OFFICE OF CONTRACT...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    ,2008 MEMORANDUM FROM: THOMAS E. BROWN, DIRECTOR OFFICE OF CONTRACT MANAGEMENT OFFICE OF PROCUREMENT AND ASSISTANCE MANAGEMENT SUBJECT: Contract Change Order Administration of...

  6. Flow Test At Fenton Hill HDR Geothermal Area (Brown, 1995) |...

    OpenEI (Open Energy Information) [EERE & EIA]

    Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Flow Test At Fenton Hill HDR Geothermal Area (Brown, 1995) Exploration Activity Details Location...

  7. Flow Test At Fenton Hill HDR Geothermal Area (Brown, 1994) |...

    OpenEI (Open Energy Information) [EERE & EIA]

    Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Flow Test At Fenton Hill HDR Geothermal Area (Brown, 1994) Exploration Activity Details Location...

  8. Systems and Professional Development - David Brown, Director, Systems &

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Professional Development, OAPM | Department of Energy Systems and Professional Development - David Brown, Director, Systems & Professional Development, OAPM Systems and Professional Development - David Brown, Director, Systems & Professional Development, OAPM Topics Discussed: Importance of Contracting in DOE Compared with Other Civilian Agencies Professional Workforce Workload DOE's Certified Workforce Acquisition Workload The Holy Grail of Contract and Project Management More...

  9. Novel Solvent System for Post Combustion CO{sub 2} Capture Brown...

    Office of Scientific and Technical Information (OSTI)

    COsub 2 Capture Brown, Alfred; Brown, Nathan 20 FOSSIL-FUELED POWER PLANTS Clean Coal Technology Coal - Environmental (Carbon Capture) Clean Coal Technology Coal -...

  10. STATE OF CALIFORNIA - THE NATURAL RESOURCES AGENCY EDMUND G. BROWN, JR., Governor

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    THE NATURAL RESOURCES AGENCY EDMUND G. BROWN, JR., Governor CALIFORNIA ENERGY COMMISSION 1516 Ninth Street, MS 14 Sacramento, California 95814 Main website: www.energy.ca.gov January 12, 2011 United States Department of Energy (DOE) Via e-mail: expartecommunications@hq.doe.gov RE: Ex parte communication of the California Energy Commission Docket No. EERE-2008-BT-STD-0005 To Whom It May Concern, On January 6, 2011, Mike Leaon, Harinder Singh, Ken Rider, and Dennis Beck of the California Energy

  11. Molecular-Level Insight into the Differential Oxidase and Oxygenase Reactivities of de Novo Due Ferri Proteins

    SciTech Connect

    Snyder, Rae Ana; Butch, Susan E.; Reig, Amanda J.; DeGrado, William F.; Solomon, Edward I.

    2015-06-19

    Using the single-chain due ferri (DFsc) peptide scaffold, the differential oxidase and oxygenase reactivities of two 4A → 4G variants, one with two histidines at the diiron center (G4DFsc) and the other with three histidines (3His-G4DFsc(Mut3)), are explored. By controlling the reaction conditions, the active form responsible for 4-aminophenol (4-AP) oxidase activity in both G4DFsc and 3His-G4DFsc(Mut3) is determined to be the substrate-bound biferrous site. Using circular dichroism (CD), magnetic CD (MCD), and variable-temperature, variable-field (VTVH) MCD spectroscopies, 4-AP is found to bind directly to the biferrous sites of the DF proteins. In G4DFsc, 4-AP increases the coordination of the biferrous site, while in 3His-G4DFsc(Mut3), the coordination number remains the same and the substrate likely replaces the additional bound histidine. This substrate binding enables a two-electron process where 4-AP is oxidized to benzoquinone imine and O2 is reduced to H2O2. In contrast, only the biferrous 3His variant is found to be active in the oxygenation of p-anisidine to 4-nitroso-methoxybenzene. From CD, MCD, and VTVH MCD, p-anisidine addition is found to minimally perturb the biferrous centers of both G4DFsc and 3His-G4DFsc(Mut3), indicating that this substrate binds near the biferrous site. Lastly, in 3His-G4DFsc(Mut3), the coordinative saturation of one iron leads to the two-electron reduction of O2 at the second iron to generate an end-on hydroperoxo-Fe(III) active oxygenating species.

  12. Brown County, Ohio: Energy Resources | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Hide Map This article is a stub. You can help OpenEI by expanding it. Brown County is a county in Ohio. Its FIPS County Code is 015. It is classified as ASHRAE...

  13. Brown County, Indiana: Energy Resources | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Hide Map This article is a stub. You can help OpenEI by expanding it. Brown County is a county in Indiana. Its FIPS County Code is 013. It is classified as ASHRAE...

  14. Brown County, Kansas: Energy Resources | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Hide Map This article is a stub. You can help OpenEI by expanding it. Brown County is a county in Kansas. Its FIPS County Code is 013. It is classified as ASHRAE...

  15. Brown County, Minnesota: Energy Resources | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Hide Map This article is a stub. You can help OpenEI by expanding it. Brown County is a county in Minnesota. Its FIPS County Code is 015. It is classified as...

  16. Brown County, Texas: Energy Resources | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Hide Map This article is a stub. You can help OpenEI by expanding it. Brown County is a county in Texas. Its FIPS County Code is 049. It is classified as ASHRAE...

  17. Brown County, South Dakota: Energy Resources | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Hide Map This article is a stub. You can help OpenEI by expanding it. Brown County is a county in South Dakota. Its FIPS County Code is 013. It is classified as...

  18. From: Meredith Brown Subject: Yellow Alert:...

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    Fri, 12 Jun 1998 17:03:23 -0500 From: Meredith Brown Subject: Yellow Alert: Small Bench Top Fire Title: Bench Top Fire Involving Use of Alcohol and Burner...

  19. Brown County, Nebraska: Energy Resources | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Hide Map This article is a stub. You can help OpenEI by expanding it. Brown County is a county in Nebraska. Its FIPS County Code is 017. It is classified as...

  20. Brown County, Wisconsin: Energy Resources | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Hide Map This article is a stub. You can help OpenEI by expanding it. Brown County is a county in Wisconsin. Its FIPS County Code is 009. It is classified as...

  1. Brown County Rural Elec Assn | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Rural Elec Assn Jump to: navigation, search Name: Brown County Rural Elec Assn Place: Minnesota Phone Number: 1-800-658-2368 Website: www.browncountyrea.coop Outage Hotline:...

  2. Brown County, Illinois: Energy Resources | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Hide Map This article is a stub. You can help OpenEI by expanding it. Brown County is a county in Illinois. Its FIPS County Code is 009. It is classified as...

  3. Brown Grease to Biodiesel Demonstration Project Report (Technical Report) |

    Office of Scientific and Technical Information (OSTI)

    SciTech Connect Brown Grease to Biodiesel Demonstration Project Report Citation Details In-Document Search Title: Brown Grease to Biodiesel Demonstration Project Report Municipal wastewater treatment facilities have typically been limited to the role of accepting wastewater, treating it to required levels, and disposing of its treatment residuals. However, a new view is emerging which includes wastewater treatment facilities as regional resource recovery centers. This view is a direct result

  4. Central Ferry-Lower Monumental

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    Involved Contact Us Search Comments Library Frequently Asked Questions Keeler-Pennwalt Wood Pole Removal Line Projects Line Rebuild, Relocation and Substation Projects Spacer...

  5. Production and degradation of oxalic acid by brown rot fungi

    SciTech Connect

    Espejo, E.; Agosin, E. )

    1991-07-01

    Our results show that all of the brown rot fungi tested produce oxalic acid in liquid as well as in semisolid cultures. Gloeophyllum trabeum, which accumulates the lowest amount of oxalic acid during decay of pine holocellulose, showed the highest polysaccharide-depolymerizing activity. Semisolid cultures inoculated with this fungus rapidly converted {sup 14}C-labeled oxalic acid to CO{sub 2} during cellulose depolymerization. The other brown rot fungi also oxidized {sup 14}C-labeled oxalic acid, although less rapidly. In contrast, semisolid cultures inoculated with the white rot fungus Coriolus versicolor did not significantly catabolize the acid and did not depolymerize the holocellulose during decay. Semisolid cultures of G. trabeum amended with desferrioxamine, a specific iron-chelating agent, were unable to lower the degree of polymerization of cellulose or to oxidize {sup 14}C-labeled oxalic acid to the extent or at the rate that control cultures did. These results suggest that both iron and oxalic acid are involved in cellulose depolymerization by brown rot fungi.

  6. United States

    Office of Legacy Management (LM)

    Office of Research and EPA 600/R-941209 Environmental Protection Development January 1993 Agency Washington, DC 20460 Offsite Environmental 57,,7 Monitoring Report Radiation Monitoring Around United States Nuclear Test Areas, Calendar Year 1992 UNITED STATES ENVIRONMENTAL PROTECTION AGENCY OFFICE OF RESEARCH AND DEVELOPMENT ENVIRONMENTAL MONITORING SYSTEMS LABORATORY-LAS VEGAS P.O. BOX 93478 LAS VEGAS. NEVADA 891 93-3478 702/798-2100 Dear Reader: Since 1954, the U.S. Environmental Protection

  7. Field Testing of Activated Carbon Injection Options for Mercury Control at TXU's Big Brown Station

    SciTech Connect

    John Pavlish; Jeffrey Thompson; Christopher Martin; Mark Musich; Lucinda Hamre

    2009-01-07

    The primary objective of the project was to evaluate the long-term feasibility of using activated carbon injection (ACI) options to effectively reduce mercury emissions from Texas electric generation plants in which a blend of lignite and subbituminous coal is fired. Field testing of ACI options was performed on one-quarter of Unit 2 at TXU's Big Brown Steam Electric Station. Unit 2 has a design output of 600 MW and burns a blend of 70% Texas Gulf Coast lignite and 30% subbituminous Powder River Basin coal. Big Brown employs a COHPAC configuration, i.e., high air-to-cloth baghouses following cold-side electrostatic precipitators (ESPs), for particulate control. When sorbent injection is added between the ESP and the baghouse, the combined technology is referred to as TOXECON{trademark} and is patented by the Electric Power Research Institute in the United States. Key benefits of the TOXECON configuration include better mass transfer characteristics of a fabric filter compared to an ESP for mercury capture and contamination of only a small percentage of the fly ash with AC. The field testing consisted of a baseline sampling period, a parametric screening of three sorbent injection options, and a month long test with a single mercury control technology. During the baseline sampling, native mercury removal was observed to be less than 10%. Parametric testing was conducted for three sorbent injection options: injection of standard AC alone; injection of an EERC sorbent enhancement additive, SEA4, with ACI; and injection of an EERC enhanced AC. Injection rates were determined for all of the options to achieve the minimum target of 55% mercury removal as well as for higher removals approaching 90%. Some of the higher injection rates were not sustainable because of increased differential pressure across the test baghouse module. After completion of the parametric testing, a month long test was conducted using the enhanced AC at a nominal rate of 1.5 lb/Macf. During the

  8. Final Surplus Plutonium Disposition Supplemental Environmental...

    National Nuclear Security Administration (NNSA)

    ... reactors at the Sequoyah and Browns Ferry Nuclear Plants of TVA, and at generic reactors. ... for use in domestic commercial nuclear power reactors to generate electricity, as well ...

  9. EIS-0283-S2-Volume1-2012.pdf

    Energy Saver

    Savannah River Site - South Carolina Sequoyah Nuclear Plant - Tennessee Browns Ferry Nuclear Plant - Alabama Waste Isolation Pilot Plant - New Mexico Los Alamos National Laboratory ...

  10. EIS-0283-S2-Volume2-2012.pdf

    Energy Saver

    SHEET Lead Agency: U.S. Department of Energy (DOE) National Nuclear Security ... at the Sequoyah and Browns Ferry Nuclear Plants of the Tennessee Valley Authority (TVA). ...

  11. Nuclear Navy United States Atomic Energy Commission Historical Advisory

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Navy United States Atomic Energy Commission Historical Advisory Committee Chairman, Alfred D. Chandler, Jr. Harvard University John T. Conway Consolidated Edison Company Lauchlin M. Currie Carmel, California A. Hunter Dupree Brown University Ernest R. May Harvard University Robert P. Multhauf Smithsonian Institution Nuclear Navy 1946-1962 Richard G. Hewlett and Francis Duncan The University of Chicago Press Chicago and London The University of Chicago Press Chicago 60637 The University of

  12. From Meredith Brown racer@lanl.gov Subject: Yellow Alert- Supplied...

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    12 Jan 2000 130859 -0700 From Meredith Brown racer@lanl.gov Subject: Yellow Alert- Supplied Air Fitting Failure Title: Yellow Alert- Mechanical Failure of Supplied Air Fitting...

  13. From: Meredith Brown Subject: Red Alert: Contaminatio...

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    Meredith Brown Subject: Red Alert: Contamination Spread Outside of RCAs ... Priority Descriptor: REDUrgent (based on the actual spread of contamination offsite) ...

  14. ATMOSPHERIC CIRCULATION OF BROWN DWARFS: JETS, VORTICES, AND TIME VARIABILITY

    SciTech Connect

    Zhang, Xi; Showman, Adam P.

    2014-06-10

    A variety of observational evidence demonstrates that brown dwarfs exhibit active atmospheric circulations. In this study we use a shallow-water model to investigate the global atmospheric dynamics in the stratified layer overlying the convective zone on these rapidly rotating objects. We show that the existence and properties of the atmospheric circulation crucially depend on key parameters including the energy injection rate and radiative timescale. Under conditions of strong internal heat flux and weak radiative dissipation, a banded flow pattern comprised of east-west jet streams spontaneously emerges from the interaction of atmospheric turbulence with the planetary rotation. In contrast, when the internal heat flux is weak and/or radiative dissipation is strong, turbulence injected into the atmosphere damps before it can self-organize into jets, leading to a flow dominated by transient eddies and isotropic turbulence instead. The simulation results are not very sensitive to the form of the forcing. Based on the location of the transition between jet-dominated and eddy-dominated regimes, we suggest that many brown dwarfs may exhibit atmospheric circulations dominated by eddies and turbulence (rather than jets) due to the strong radiative damping on these worlds, but a jet structure is also possible under some realistic conditions. Our simulated light curves capture important features from observed infrared light curves of brown dwarfs, including amplitude variations of a few percent and shapes that fluctuate between single-peak and multi-peak structures. More broadly, our work shows that the shallow-water system provides a useful tool to illuminate fundamental aspects of the dynamics on these worlds.

  15. From: Doris Brown To: Congestion Study Comments Subject: NIETCs

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Doris Brown To: Congestion Study Comments Subject: NIETCs Date: Monday, October 20, 2014 2:47:39 PM I am opposed to the establishment of National Interest Energy Transmission Corridors (NIETC's) Easements for the corridors will mainly have to be obtained through eminent domain. Compensation for the easements can only be "just" as required in the Bill of Rights if it reflects all the possibilities of what the easement may be used for. Utilities do not want to farm the land, so farming

  16. DISCOVERY OF A CANDIDATE FOR THE COOLEST KNOWN BROWN DWARF

    SciTech Connect

    Luhman, K. L.; Bochanski, J. J.; Burgasser, A. J.

    2011-03-20

    We have used multi-epoch images from the Infrared Array Camera on board the Spitzer Space Telescope to search for substellar companions to stars in the solar neighborhood based on common proper motions. Through this work, we have discovered a faint companion to the white dwarf WD 0806-661. The comoving source has a projected separation of 130'', corresponding to 2500 AU at the distance of the primary (19.2 pc). If it is physically associated, then its absolute magnitude at 4.5 {mu}m is {approx}1 mag fainter than the faintest known T dwarfs, making it a strong candidate for the coolest known brown dwarf. The combination of M{sub 4.5} and the age of the primary (1.5 Gyr) implies an effective temperature of {approx}300 K and a mass of {approx}7 M{sub Jup} according to theoretical evolutionary models. The white dwarf's progenitor likely had a mass of {approx}2 M{sub sun}, and thus could have been born with a circumstellar disk that was sufficiently massive to produce a companion with this mass. Therefore, the companion could be either a brown dwarf that formed like a binary star or a giant planet that was born within a disk and has been dynamically scattered to a larger orbit.

  17. NEOWISE-R observation of the coolest known brown dwarf

    SciTech Connect

    Wright, Edward L.; Mainzer, Amy; Bauer, James; Eisenhardt, Peter R. M.; Davy Kirkpatrick, J.; Masci, Frank; Fajardo-Acosta, Sergio; Gelino, Christopher R.; Beichman, Charles A.; Cutri, Roc; Cushing, Michael C.; Skrutskie, M. F.; Grav, T.

    2014-11-01

    The Wide-field Infrared Survey Explorer (WISE) spacecraft has been reactivated as NEOWISE-R to characterize and search for near-Earth objects. The brown dwarf WISE J085510.83–071442.5 has now been re-observed by NEOWISE-R, and we confirm the results of Luhman, who found a very low effective temperature (≈250 K), a very high proper motion (8.''1 ± 0.''1 yr{sup –1}), and a large parallax (454 ± 45 mas). The large proper motion has separated the brown dwarf from the background sources that influenced the 2010 WISE data, allowing a measurement of a very red WISE color of W1 – W2 >3.9 mag. A re-analysis of the 2010 WISE astrometry using only the W2 band, combined with the new NEOWISE-R 2014 position, gives an improved parallax of 448 ± 33 mas and a proper motion of 8.''08 ± 0.''05 yr{sup –1}. These are all consistent with values from Luhman.

  18. CONFIRMATION OF ONE OF THE COLDEST KNOWN BROWN DWARFS

    SciTech Connect

    Luhman, K. L.; Bochanski, J. J.; Burgasser, A. J.; Labbe, I.; Monson, A. J.; Persson, S. E.; Saumon, D.; Marley, M. S.

    2012-01-10

    Using two epochs of 4.5 {mu}m images from the Infrared Array Camera (IRAC) on board the Spitzer Space Telescope, we recently identified a common proper motion companion to the white dwarf WD 0806-661 that is a candidate for the coldest known brown dwarf. To verify its cool nature, we have obtained images of this object at 3.6 {mu}m with IRAC, at J with the High Acuity Wide-field K-band Imager (HAWK-I) on the Very Large Telescope, and in a filter covering the red half of J with FourStar on Magellan. WD 0806-661 B is detected by IRAC but not HAWK-I or FourStar. From these data we measure colors of [3.6] - [4.5] = 2.77 {+-} 0.16 and J - [4.5] > 7.0 (S/N < 3). Based on these colors and its absolute magnitudes, WD 0806-661 B is the coldest companion directly imaged outside of the solar system and is a contender for the coldest known brown dwarf with the Y dwarf WISEP J1828+2650. It is unclear which of these two objects is colder given the available data. A comparison of its absolute magnitude at 4.5 {mu}m to the predictions of theoretical spectra and evolutionary models suggests that WD 0806-661 B has T{sub eff} = 300-345 K.

  19. United States

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    E-T Global Energy, LLC OE Docket No. EA-381 Order Authorizing Electricity Exports to Mexico Order No. EA-381 June 10, 2011 I. BACKGROUND E-T Global Energy, LLC Order No. EA-381 Exports of electricity from the United States to a foreign country are regulated by the Department of Energy (DOE) pursuant to sections 301(b) and 402(f) of the Department ofEnergy Organization Act (42 U.S.C. 7151(b), 7172(f)) and require authorization under section 202(e) ofthe Federal Power Act (FPA) (16 U.S.C.824a(e))

  20. United States

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Tenaslta Power Services Co. OE Docket No. EA-243-A Order Authorizing Electricity Exports to Canada Order No. EA-243-A March 1,2007 Tenaska Power Services Co. Order No. EA-243-A I. BACKGROUND Exports of elcctricity from the United States to a foreign country are regulated by the Department of Energy (DOE) pursuant to sections 30 I(b) and 402(f) of the Departrncnt of' Energy Organizatio~l Act (42 U, S.C. 7 15 1 (b), 7 1 72Cf)) and rcquirc authorization under section 202(e) of the Federal Power Act

  1. United States

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    TexMex Energy, LLC OE Docket No. EA-294-A Order Authorizing Electricity Exports to Mexico Order No. EA-294-A February 22, 2007 TexMex Energy, LLC Order No. EA-294-A I. BACKGROUND Exports of electricity from the United States to a foreign count~y are regulated by the Department of Energy (DOE) pursuant to sections 301(b) and 402(f) of the Department of Energy Organization Act (42 U.S.C. 7 15 1 (b), 71 72(f)) and require authorization under section 202(e) of the Federal Power Act (FPA) (16

  2. United States

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    BP Energy Company OE Docket No. EA- 3 14 Order Authorizing Electricity Exports to Mexico Order No. EA-3 14 February 22,2007 BP Energy Company Order No. EA-314 I. BACKGROUND Exports of electricity from the United States to a foreign country are regulated by the Department of Energy (DOE) pursuant to sections 301(b) and 402(Q of the Department of Energy Organization Act (42 U.S.C. 7 15 l(b), 7172(f)) and require authorization under section 202(e) of the Federal Power Act (FPA) (16 U.S.C.S24a(e)) .

  3. United States

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    CSW Power Marketing OE Docket No. EA-3 1 8 Order Authorizing Electricity Exports to Mexico Order No. EA-3 18 February 22,2007 CSW Power Marketing Order No. EA-318 I. BACKGROUND Exports of electricity from the United States to a foreign country are regulated by the Department of Energy (DOE) pursuant to sections 30l(b) and 402(f) of the Department of Energy Organization Act (42 U.S.C. 7 1 5 1 (b), 7 1 72(f)) and require authorization under section 202(e) of the Federal Power Act (FPA) (16

  4. Rheological properties of water-coal slurries based on brown coal in the presence of sodium lignosulfonates and alkali

    SciTech Connect

    D.P. Savitskii; A.S. Makarov; V.A. Zavgorodnii

    2009-07-01

    The effect of the oxidized surface of brown coal on the structural and rheological properties of water-coal slurries was found. The kinetics of structure formation processes in water-coal slurries based on as-received and oxidized brown coal was studied. The effect of lignosulfonate and alkali additives on the samples of brown coal was considered.

  5. Alabama Nuclear Profile - Power Plants

    Energy Information Administration (EIA) (indexed site)

    nuclear power plants, summer capacity and net generation, 2010" "Plant name/total reactors","Summer capacity (mw)","Net generation (thousand mwh)","Share of State nuclear net generation (percent)","Owner" "Browns Ferry Unit 1, Unit 2, Unit 3","3,309","24,771",65.3,"Tennessee Valley Authority" "Joseph M Farley Unit 1, Unit 2","1,734","13,170",34.7,"Alabama Power

  6. Analysis of high pressure boil-off situation during MSIV closure ATWS in a typical BWR/4

    SciTech Connect

    Neymotin, L.Y.; Slovik, G.C.; Saha, P.

    1986-01-01

    The objective of this paper is to provide a best-estimate analysis of the MSIV Closure ATWS in the Browns Ferry Unit 1 BWR with Mark 1 containment. The calculations have been performed using the RAMONA-3B code which has a three-dimensional neutron kinetics model coupled with one-dimensional (multi-channel core representation), four-equation, nonhomogeneous, nonequilibrium thermal hydraulics. The code also allows for one-dimensional neutronic core representation. The 1-D capability of the code has been employed in this calculation since a thorough sensitivity study showed that for a full ATWS, a one-dimensional (axial) neutron kinetics adequately describes the core behavior. (Note that the core steady-state symmetry in this case was preserved throughout the transient so that radial effects could be neglected.) The calculation described in the paper was started from a steady-state fuel condition corresponding to the end of Cycle 5 of the Browns Ferry reactor.

  7. 2016-3-17_Allocations_Brown_Bag

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    Bagwell & Richard Gerber! ! NERSC Brown Bag! March 17, 2016 Allocations --- 1 --- Allocations Summary * How t he N ERSC p ie i s d istributed - A l i'le h istory * DOE O ffices & P rograms * NERSC r eserves * The E RCAP p rocess * How u ser a ccounts a nd a llocaBons w ork * What h appens w hen u ser/repo r un o ut o f B me * Q & A --- 2 --- Allocations History 0 500000000 1E+09 1.5E+09 2E+09 2.5E+09 3E+09 3.5E+09 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016

  8. Termination unit

    SciTech Connect

    Traeholt, Chresten; Willen, Dag; Roden, Mark; Tolbert, Jerry C; Lindsay, David; Fisher, Paul W; Nielsen, Carsten Thidemann

    2014-01-07

    This invention relates to a termination unit comprising an end-section of a cable. The end section of the cable defines a central longitudinal axis and comprising end-parts of N electrical phases, an end-part of a neutral conductor and a surrounding thermally insulation envelope adapted to comprising a cooling fluid. The end-parts of the N electrical phases and the end-part of the neutral conductor each comprising at least one electrical conductor and being arranged in the cable concentrically around a core former with a phase 1 located relatively innermost, and phase N relatively outermost in the cable, phase N being surrounded by the neutral conductor, electrical insulation being arrange between neighboring electrical phases and between phase N and the neutral conductor, and wherein the end-parts of the neutral conductor and the electrical phases each comprise a contacting surface electrically connected to at least one branch current lead to provide an electrical connection: The contacting surfaces each having a longitudinal extension, and being located sequentially along the longitudinal extension of the end-section of the cable. The branch current leads being individually insulated from said thermally insulation envelope by individual electrical insulators.

  9. Craig Brown | Center for Gas SeparationsRelevant to Clean Energy...

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    Bloch, Eric D; Queen, Wendy L; Krishna, Rajamani; Zadrozny, Joseph M.; Brown, Craig M; and Long, Jeffrey R Hydrocarbon Separations in a Metal-Organic Framework with Open Iron(II) ...

  10. Laboratory measurements of resistivity in warm dense plasmas relevant to the microphysics of brown dwarfs

    SciTech Connect

    Booth, N.; Robinson, A. P. L.; Hakel, P.; Clarke, R. J.; Dance, R. J.; Doria, D.; Gizzi, L. A.; Gregori, G.; Koester, P.; Labate, L.; Levato, T.; Li, B.; Makita, M.; Mancini, R. C.; Pasley, J.; Rajeev, P. P.; Riley, D.; Wagenaars, E.; Waugh, J. N.; Woolsey, N. C.

    2015-11-06

    Since the observation of the first brown dwarf in 1995, numerous studies have led to a better understanding of the structures of these objects. Here we present a method for studying material resistivity in warm dense plasmas in the laboratory, which we relate to the microphysics of brown dwarfs through viscosity and electron collisions. Here we use X-ray polarimetry to determine the resistivity of a sulphur-doped plastic target heated to Brown Dwarf conditions by an ultra-intense laser. The resistivity is determined by matching the plasma physics model to the atomic physics calculations of the measured large, positive, polarization. Furthermore, the inferred resistivity is larger than predicted using standard resistivity models, suggesting that these commonly used models will not adequately describe the resistivity of warm dense plasma related to the viscosity of brown dwarfs.

  11. Travis Brown and Kamran Baksh, Final Submission | OpenEI Community

    OpenEI (Open Energy Information) [EERE & EIA]

    Travis Brown and Kamran Baksh, Final Submission Home > Groups > 2014 Geothermal Case Study Challenge CSM's picture Submitted by CSM(5) Member 14 May, 2014 - 21:59 Colorado School...

  12. Laboratory measurements of resistivity in warm dense plasmas relevant to the microphysics of brown dwarfs

    DOE PAGES [OSTI]

    Booth, N.; Robinson, A. P. L.; Hakel, P.; Clarke, R. J.; Dance, R. J.; Doria, D.; Gizzi, L. A.; Gregori, G.; Koester, P.; Labate, L.; et al

    2015-11-06

    Since the observation of the first brown dwarf in 1995, numerous studies have led to a better understanding of the structures of these objects. Here we present a method for studying material resistivity in warm dense plasmas in the laboratory, which we relate to the microphysics of brown dwarfs through viscosity and electron collisions. Here we use X-ray polarimetry to determine the resistivity of a sulphur-doped plastic target heated to Brown Dwarf conditions by an ultra-intense laser. The resistivity is determined by matching the plasma physics model to the atomic physics calculations of the measured large, positive, polarization. Furthermore, themore » inferred resistivity is larger than predicted using standard resistivity models, suggesting that these commonly used models will not adequately describe the resistivity of warm dense plasma related to the viscosity of brown dwarfs.« less

  13. THERESA BROWN SHUTE RECOGNIZED AS OE EMPLOYEE OF THE QUARTER FOR EXCELLENCE

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    | Department of Energy About Us » THERESA BROWN SHUTE RECOGNIZED AS OE EMPLOYEE OF THE QUARTER FOR EXCELLENCE THERESA BROWN SHUTE RECOGNIZED AS OE EMPLOYEE OF THE QUARTER FOR EXCELLENCE The OE Employee of the Quarter for Excellence Recognition Program profiles inspirational employees in the Office of Electricity Delivery & Energy Reliability (OE) who have demonstrated one or more of the following principles in their professionalism: Embodied the values of both the Department and OE;

  14. Taking It from Brown to Green: Renewable Energy on Contaminated Lands |

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Department of Energy Taking It from Brown to Green: Renewable Energy on Contaminated Lands Taking It from Brown to Green: Renewable Energy on Contaminated Lands This presentation, presented April 22, 2009, covered renewable energy on contaminated sites. Presenters included Otto Van Geet from the National Renewable Energy Laboratory, Brian K. Johnson from the New Mexico Energy Minerals and Natural Resources Department, and Pam Swingle from the U.S. Environmental Protection Agency. Taking It

  15. A new parallax measurement for the coldest known brown dwarf

    SciTech Connect

    Luhman, K. L.; Esplin, T. L.

    2014-11-20

    WISE J085510.83–071442.5 was recently discovered as the coldest known brown dwarf based on four epochs of images from the Wide-field Infrared Survey Explorer and the Spitzer Space Telescope. We have improved the accuracy of its parallax measurement by obtaining two additional epochs of Spitzer astrometry. We derive a parallactic distance of 2.31 ± 0.08 pc, which continues to support its rank as the fourth closest known system to the Sun when compared to WISE J104915.57–531906.1 AB (2.02 ± 0.02 pc) and Wolf 359 (2.386 ± 0.012 pc). The new constraint on the absolute magnitude at 4.5 μm indicates an effective temperature of 235-260 K based on four sets of theoretical models. We also show the updated positions of WISE J085510.83–071442.5 in two color-magnitude diagrams. Whereas Faherty and coworkers cited its location in M {sub W2} versus J – W2 as evidence of water clouds, we find that those data can be explained instead by cloudless models that employ non-equilibrium chemistry.

  16. Fermilab | Tritium at Fermilab | Ferry Creek Results

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    has been taken and analyzed. For samples in which a level of tritium above the limit of detection has been measured, the uncertainty of the measurement is indicated by an error...

  17. Central Ferry Lower Monumental | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    within the project area that would pose an immediate threat to human health or the environment. Other conditions such as large dump sites, drums of unknown substances,...

  18. Spectroscopic, scanning laser OBIC, and I-V/QE characterizations of browned EVA solar cells

    SciTech Connect

    Pern, F.J.; Eisgruber, I.L.; Micheels, R.H.

    1996-05-01

    The effects of ethylene-vinyl acetate (EVA) discoloration due to accelerated field or laboratory exposure on the encapsulated silicon (Si) solar cells or EVA/glass laminates were characterized quantitatively by using non-invasive, non-destructive ultraviolet-visible (UV-vis) spectrophotometry, spectrocolorimetry, spectrofluorometry, scanning laser OBIC (optical beam induced current) spectroscopy, and current-voltage (I-V) and quantum efficiency (QE) measurements. The results show that the yellowness index (YI) measured directly over the AR-coated solar cells under the glass superstrate increased from the range of -80 to -90 to the range of -20 to 15 as the EVA changed from clear to brown. The ratio of two fluorescence emission peak areas generally increased from 1.45 to 5.69 as browning increased, but dropped to 4.21 on a darker EVA. For a solar cell with brown EVA in the central region, small-area grating QE measurements and scanning laser OBIC analysis between the brown and clear EVA regions showed that the quantum efficiency loss at 633 nm was 42%-48% of the loss at 488 nm, due to a reduced decrease of transmittance in browned EVA at the longer wavelengths. The portion of the solar cell under the browned EVA showed a decrease of {approximately}36% in efficiency, as compared to the cell efficiency under clear EVA. Transmittance loss at 633 nm was 38% of the loss at 488 nm for a light yellow-brown EVA/glass laminate that showed a small increase of 10 in the yellowness index.

  19. United States Department of Energy

    Office of Environmental Management (EM)

    security determinations should err, if they must, on the side of denials"); Dorfmont v. Brown, 913 F.2d 1399, 1403 (9 th Cir. 1990), cert. denied, 499 U.S. 905 (1991) (strong...

  20. A data-driven approach for retrieving temperatures and abundances in brown dwarf atmospheres

    SciTech Connect

    Line, Michael R.; Fortney, Jonathan J.; Marley, Mark S.; Sorahana, Satoko

    2014-09-20

    Brown dwarf spectra contain a wealth of information about their molecular abundances, temperature structure, and gravity. We present a new data driven retrieval approach, previously used in planetary atmosphere studies, to extract the molecular abundances and temperature structure from brown dwarf spectra. The approach makes few a priori physical assumptions about the state of the atmosphere. The feasibility of the approach is first demonstrated on a synthetic brown dwarf spectrum. Given typical spectral resolutions, wavelength coverage, and noise, property precisions of tens of percent can be obtained for the molecular abundances and tens to hundreds of K on the temperature profile. The technique is then applied to the well-studied brown dwarf, Gl 570D. From this spectral retrieval, the spectroscopic radius is constrained to be 0.75-0.83 R {sub J}, log (g) to be 5.13-5.46, and T {sub eff} to be between 804 and 849 K. Estimates for the range of abundances and allowed temperature profiles are also derived. The results from our retrieval approach are in agreement with the self-consistent grid modeling results of Saumon et al. This new approach will allow us to address issues of compositional differences between brown dwarfs and possibly their formation environments, disequilibrium chemistry, and missing physics in current grid modeling approaches as well as a many other issues.

  1. Estimating Renewable Energy Economic Potential in the United States: Methodology and Initial

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Estimating Renewable Energy Economic Potential in the United States: Methodology and Initial Results Austin Brown, Philipp Beiter, Donna Heimiller, Carolyn Davidson, Paul Denholm, Jennifer Melius, Anthony Lopez, Dylan Hettinger, David Mulcahy, and Gian Porro Webinar, 02/24/16 Philipp Beiter Energy Markets and Policy Analyst NREL Presenter: 2 PRELIMINARY - NOT FOR DISTRIBUTION, PUBLICATION, QUOTATION, OR CITATION Topics I. U.S. Renewable Energy Trends 1. Capacity and Generation 2. Capacity

  2. " Million Housing Units, Final...

    Energy Information Administration (EIA) (indexed site)

    ... central air conditioning equipment for a business or farm building as well as another ... ,,"RSEs for Housing Unit Type" ,,"Single-Family Units",,"Apartments in Buildings With" ...

  3. EIS-0435: Modification of the Groton Generation Station Interconnection Agreement, Brown County, South Dakota

    Energy.gov [DOE]

    This EIS evaluates the environmental impacts of a proposal for DOE's Western Area Power Administration to modify its Large Generator Connection Agreement for the Groton Generation Station in Brown County, South Dakota. The modification would allow Basin Electric Power Cooperative, which operates the generation station, to produce power above the current operating limit of 50 average megawatts.

  4. Summary Max Total Units

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Summary Max Total Units *If All Splits, No Rack Units **If Only FW, AC Splits 1000 52 28 28 2000 87 59 35 3000 61 33 15 4000 61 33 15 Totals 261 153 93 ***Costs $1,957,500.00 $1,147,500.00 $697,500.00 Notes: added several refrigerants removed bins from analysis removed R-22 from list 1000lb, no Glycol, CO2 or ammonia Seawater R-404A only * includes seawater units ** no seawater units included *** Costs = (total units) X (estimate of $7500 per unit) 1000lb, air cooled split systems, fresh water

  5. Spitzer and z' secondary eclipse observations of the highly irradiated transiting brown dwarf KELT-1b

    SciTech Connect

    Beatty, Thomas G.; Gaudi, B. Scott; Collins, Karen A.; Kielkopf, John F.; Fortney, Jonathan; Knutson, Heather; Bruns, Jacob M.; Showman, Adam P.; Eastman, Jason; Pepper, Joshua; Siverd, Robert J.; Stassun, Keivan G.

    2014-03-10

    We present secondary eclipse observations of the highly irradiated transiting brown dwarf KELT-1b. These observations represent the first constraints on the atmospheric dynamics of a highly irradiated brown dwarf, the atmospheres of irradiated giant planets at high surface gravity, and the atmospheres of brown dwarfs that are dominated by external, rather than internal, energy. Using the Spitzer Space Telescope, we measure secondary eclipse depths of 0.195% ± 0.010% at 3.6 μm and 0.200% ± 0.012% at 4.5 μm. We also find tentative evidence for the secondary eclipse in the z' band with a depth of 0.049% ± 0.023%. These measured eclipse depths are most consistent with an atmosphere model in which there is a strong substellar hotspot, implying that heat redistribution in the atmosphere of KELT-1b is low. While models with a more mild hotspot or even with dayside heat redistribution are only marginally disfavored, models with complete heat redistribution are strongly ruled out. The eclipse depths also prefer an atmosphere with no TiO inversion layer, although a model with TiO inversion is permitted in the dayside heat redistribution case, and we consider the possibility of a day-night TiO cold trap in this object. For the first time, we compare the IRAC colors of brown dwarfs and hot Jupiters as a function of effective temperature. Importantly, our measurements reveal that KELT-1b has a [3.6] – [4.5] color of 0.07 ± 0.11, identical to that of isolated brown dwarfs of similarly high temperature. In contrast, hot Jupiters generally show redder [3.6] – [4.5] colors of ∼0.4, with a very large range from ∼0 to ∼1. Evidently, despite being more similar to hot Jupiters than to isolated brown dwarfs in terms of external forcing of the atmosphere by stellar insolation, KELT-1b appears to have an atmosphere most like that of other brown dwarfs. This suggests that surface gravity is very important in controlling the atmospheric systems of substellar mass bodies.

  6. CHARACTERIZING THE BROWN DWARF FORMATION CHANNELS FROM THE INITIAL MASS FUNCTION AND BINARY-STAR DYNAMICS

    SciTech Connect

    Thies, Ingo; Pflamm-Altenburg, Jan; Kroupa, Pavel; Marks, Michael

    2015-02-10

    The stellar initial mass function (IMF) is a key property of stellar populations. There is growing evidence that the classical star-formation mechanism by the direct cloud fragmentation process has difficulties reproducing the observed abundance and binary properties of brown dwarfs and very-low-mass stars. In particular, recent analytical derivations of the stellar IMF exhibit a deficit of brown dwarfs compared to observational data. Here we derive the residual mass function of brown dwarfs as an empirical measure of the brown dwarf deficiency in recent star-formation models with respect to observations and show that it is compatible with the substellar part of the Thies-Kroupa IMF and the mass function obtained by numerical simulations. We conclude that the existing models may be further improved by including a substellar correction term that accounts for additional formation channels like disk or filament fragmentation. The term ''peripheral fragmentation'' is introduced here for such additional formation channels. In addition, we present an updated analytical model of stellar and substellar binarity. The resulting binary fraction and the dynamically evolved companion mass-ratio distribution are in good agreement with observational data on stellar and very-low-mass binaries in the Galactic field, in clusters, and in dynamically unprocessed groups of stars if all stars form as binaries with stellar companions. Cautionary notes are given on the proper analysis of mass functions and the companion mass-ratio distribution and the interpretation of the results. The existence of accretion disks around young brown dwarfs does not imply that these form just like stars in direct fragmentation.

  7. " Million Housing Units, Final...

    Energy Information Administration (EIA) (indexed site)

    ... the use of the heating equipment for a business or farm building as well as another ... for Housing Unit Type" ,,,,"Single-Family Units",,,,"Apartments in Buildings With" ...

  8. " Million Housing Units, Final...

    Energy Information Administration (EIA) (indexed site)

    ... the use of the heating equipment for a business or farm building as well as another ... ,,"RSEs for Housing Unit Type" ,,"Single-Family Units",,"Apartments in Buildings With" ...

  9. Nuclear reactor characteristics and operational history

    Gasoline and Diesel Fuel Update

    Capacity Release date: October 21, 2015 Next release date: October, 2016 See also: Table 2. Ownership Data Table 1. Nuclear Reactor, State, and Net Capacity Plant/Reactor Name Generator ID State 2014 Summer Capacity Net MW(e)1 Arkansas Nuclear One 1 AR 833.8 Arkansas Nuclear One 2 AR 985.8 Beaver Valley 1 PA 920 Beaver Valley 2 PA 914 Braidwood Generation Station 1 IL 1178 Braidwood Generation Station 2 IL 1152 Browns Ferry 1 AL 1100.8 Browns Ferry 2 AL 1103.7 Browns Ferry 3 AL 1104.9 Brunswick

  10. A Spatial Hedonic Analysis of the Effects of Wind Energy Facilities on Surrounding Property Values in the United States

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    LBNL-6362E ERNEST ORLANDO LAWRENCE BERKELEY NATIONAL LABORATORY A Spatial Hedonic Analysis of the Effects of Wind Energy Facilities on Surrounding Property Values in the United States Ben Hoen, Jason P. Brown, Thomas Jackson, Ryan Wiser, Mark Thayer and Peter Cappers Environmental Energy Technologies Division August 2013 Download from http://emp.lbl.gov/reports/re This work was supported by the Office of Energy Efficiency and Renewable Energy (Wind and Water Power Technologies Office) of the

  11. Palynostratigraphy of the Erkovtsy field of brown coal (the Zeya-Bureya sedimentary basin)

    SciTech Connect

    Kezina, T.V.; Litvinenko, N.D.

    2007-08-15

    The Erkovtsy brown coal field in the northwestern Zeya-Bureya sedimentary basin (129-130{sup o}E, 46-47{sup o}N) is structurally confined to southern flank of the Mesozoic-Cenozoic Belogor'e depression. The verified stratigraphic scheme of the coalfield sedimentary sequence is substantiated by palynological data on core samples from 18 boreholes sampled in the course of detailed prospecting and by paleobotanical analysis of sections in the Yuzhnyi sector of the coalfield (data of 1998 by M.A. Akhmetiev and S.P. Manchester). Sections of the Erkovtsy, Arkhara-Boguchan, and Raichikha brown-coal mines are correlated. Stratigraphic subdivisions distinguished in the studied sedimentary succession are the middle and upper Tsagayan subformations (the latter incorporating the Kivda Beds), Raichikha, Mukhino, Buzuli, and Sazanka formations.

  12. Dr. Benjamin L. Brown | U.S. DOE Office of Science (SC)

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    Benjamin L. Brown Deputy Director for Science Programs Deputy Director Home Mission & Functions Deputy Director Biography Organization Staff Presentations & Testimony Federal Advisory Committees Committees of Visitors Contact Information Deputy Director for Science Programs U.S. Department of Energy SC-2/Forrestal Building 1000 Independence Ave., SW Washington, DC 20585 P: (202) 586-5430 F: (202) 586-4120 E: Email Us U.S. Department of Energy SC-2/Germantown Building 1000 Independence

  13. Methane, carbon monoxide, and ammonia in brown dwarfs and self-luminous giant planets

    SciTech Connect

    Zahnle, Kevin J.; Marley, Mark S. E-mail: Mark.S.Marley@NASA.gov

    2014-12-10

    We address disequilibrium abundances of some simple molecules in the atmospheres of solar composition brown dwarfs and self-luminous extrasolar giant planets using a kinetics-based one-dimensional atmospheric chemistry model. Our approach is to use the full kinetics model to survey the parameter space with effective temperatures between 500 K and 1100 K. In all of these worlds, equilibrium chemistry favors CH{sub 4} over CO in the parts of the atmosphere that can be seen from Earth, but in most disequilibrium favors CO. The small surface gravity of a planet strongly discriminates against CH{sub 4} when compared to an otherwise comparable brown dwarf. If vertical mixing is like Jupiter's, the transition from methane to CO occurs at 500 K in a planet. Sluggish vertical mixing can raise this to 600 K, but clouds or more vigorous vertical mixing could lower this to 400 K. The comparable thresholds in brown dwarfs are 1100 100 K. Ammonia is also sensitive to gravity, but, unlike CH{sub 4}/CO, the NH{sub 3}/N{sub 2} ratio is insensitive to mixing, which makes NH{sub 3} a potential proxy for gravity. HCN may become interesting in high-gravity brown dwarfs with very strong vertical mixing. Detailed analysis of the CO-CH{sub 4} reaction network reveals that the bottleneck to CO hydrogenation goes through methanol, in partial agreement with previous work. Simple, easy to use quenching relations are derived by fitting to the complete chemistry of the full ensemble of models. These relations are valid for determining CO, CH{sub 4}, NH{sub 3}, HCN, and CO{sub 2} abundances in the range of self-luminous worlds we have studied, but may not apply if atmospheres are strongly heated at high altitudes by processes not considered here (e.g., wave breaking).

  14. Advanced Rooftop Unit Control

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    Advanced-Rooftop-Unit-Control Sign In About | Careers | Contact | Investors | bpa.gov Search Policy & Reporting Expand Policy & Reporting EE Sectors Expand EE Sectors...

  15. UNITED STATES GOVERNMENT

    Office of Legacy Management (LM)

    AEC ..J. Ccnmigl.io - Chief of Middlesex Operaticns A. PIhot -Hadiation Section, ... (loose in case of large contaminated units) loaded on truck&and lsonltored at' MIddlesex. ...

  16. Composite stabilizer unit

    DOEpatents

    Ebaugh, Larry R.; Sadler, Collin P.; Carter, Gary D.

    1992-01-01

    An improved fin stabilized projectile including multiple stabilizer fins upon a stabilizer unit situated at the aft end of the projectile is provided, the improvement wherein the stabilizer fins are joined into the stabillizer unit by an injection molded engineering grade polymer.

  17. Associative list processing unit

    DOEpatents

    Hemmert, Karl Scott; Underwood, Keith D.

    2013-01-29

    An associative list processing unit and method comprising employing a plurality of prioritized cell blocks and permitting inserts to occur in a single clock cycle if all of the cell blocks are not full. Also, an associative list processing unit and method comprising employing a plurality of prioritized cell blocks and using a tree of prioritized multiplexers descending from the plurality of cell blocks.

  18. Electrical equipment performance under severe accident conditions (BWR/Mark 1 plant analysis): Summary report

    SciTech Connect

    Bennett, P.R.; Kolaczkowski, A.M.; Medford, G.T.

    1986-09-01

    The purpose of the Performance Evaluation of Electrical Equipment during Severe Accident States Program is to determine the performance of electrical equipment, important to safety, under severe accident conditions. In FY85, a method was devised to identify important electrical equipment and the severe accident environments in which the equipment was likely to fail. This method was used to evaluate the equipment and severe accident environments for Browns Ferry Unit 1, a BWR/Mark I. Following this work, a test plan was written in FY86 to experimentally determine the performance of one selected component to two severe accident environments.

  19. DOE/EIS-0283-S2

    National Nuclear Security Administration (NNSA)

    ... I-18 Table of Contents xxvii Appendix J Table J-1 Partial Mixed Oxide and Full Low-Enriched Uranium Core Inventories for the Sequoyah and Browns Ferry Nuclear Power Plants ...

  20. Voltage verification unit

    DOEpatents

    Martin, Edward J.

    2008-01-15

    A voltage verification unit and method for determining the absence of potentially dangerous potentials within a power supply enclosure without Mode 2 work is disclosed. With this device and method, a qualified worker, following a relatively simple protocol that involves a function test (hot, cold, hot) of the voltage verification unit before Lock Out/Tag Out and, and once the Lock Out/Tag Out is completed, testing or "trying" by simply reading a display on the voltage verification unit can be accomplished without exposure of the operator to the interior of the voltage supply enclosure. According to a preferred embodiment, the voltage verification unit includes test leads to allow diagnostics with other meters, without the necessity of accessing potentially dangerous bus bars or the like.

  1. Associative list processing unit

    DOEpatents

    Hemmert, Karl Scott; Underwood, Keith D

    2014-04-01

    An associative list processing unit and method comprising employing a plurality of prioritized cell blocks and permitting inserts to occur in a single clock cycle if all of the cell blocks are not full.

  2. United States Government

    Office of Legacy Management (LM)

    81278 United States Government Department of Energy memorandum - ?71 S.EP 23 F; i: 54 DATE: SEP 1 8 1991 REPLY TO ATTNOF: EM-421 (P. Blom, 3-8148) SUBJECT: Approved Categorical...

  3. Trenton strata in western Illinois Basin, Brown and Schuyler Counties, Illinois

    SciTech Connect

    Pochel, R.M.

    1984-12-01

    Trenton strata in the western Illinois basin are very good prospects for oil exploration. Much drilling has been done in the area but, as yet, no producing wells have been completed. Oil stains and some tars have been found in some samples from most wells. The Trenton in the area of Brown and Schuyler Counties is a fine-grained limestone that underlies the Maquoketa Shale at an average depth of 800 ft (244 m). Because of its position near the edge of the Illinois basin, the stratigraphy varies considerably and inconsistencies are present in most samples viewed.

  4. Mid-infrared followup of cold brown dwarfs: diversity in age, mass and metallicity

    SciTech Connect

    Saumon, Didier; Leggett, Sandy K; Burningham, Ben; Marley, Mark S; Waren, S J; Jones, H R A; Pinfield, D J; Smart, R L

    2009-01-01

    We present new Spitzer IRAC [3.6], [4.5], [5.8] and [8.0] photometry of nine very late-type T dwarfs. Combining this with previously published photometry, we investigate trends with type and color that are useful for both the planning and interpretation of infrared surveys designed to discover the coldest T or Y dwarfs. Brown dwarfs with effective temperature (T{sub eff}) below 700 K emit more than half their flux at wavelengths longer than 3 {micro}m, and the ratio of the mid-infrared flux to the near-infrared flux becomes very sensitive to T{sub eff} at these low temperatures. We confirm that the color H (1.6 {micro}m) - [4.5] is a good indicator of T{sub eff} with a relatively weak dependence on metallicity and gravity. Conversely, the colors H - K (2.2 {micro}m) and [4.5] - [5.8] are sensitive to metallicity and gravity. Thus near- and mid-infrared photometry provide useful indicators of the fundamental properties of brown dwarfs, and if temperature and gravity are known, then mass and age can be reliably determined from evolutionary models. There are twelve dwarfs currently known with H - [4.5] > 3.0, and {approx} 500 < T{sub eff} K {approx}< 800, which we examine in detail. The ages of the dwarfs in the sample range from very young (0.1 - 1.0 Gyr) to relatively old (3 - 12 Gyr). The mass range is possibly as low as 5 Jupiter masses to up to 70 Jupiter masses, i.e. near the hydrogen burning limit. The metallicities also span a large range, from [m/H]= -0.3 to [m/H]= +0.2. The small number of T8 - T9 dwarfs found in the UKIRT Infrared Deep Sky Survey to date appear to be predominantly young low-mass dwarfs. Accurate mid-infrared photometry of cold brown dwarfs is essentially impossible from the ground, and extensions to the mid-infrared space missions warm-Spitzer and WISE are desirable in order to obtain the vital mid-infrared data for cold brown dwarfs, and to discover more of these rare objects.

  5. Speakers: Adam Sieminski, Deutsche Bank Stephen P. A. Brown, Resources for the Future

    Gasoline and Diesel Fuel Update

    5: "Energy and the Economy" Speakers: Adam Sieminski, Deutsche Bank Stephen P. A. Brown, Resources for the Future Donald L. Paul, University of Southern California Energy Institute David Sandalow, DOE Christof Rühl, Group Chief Economist, BP [Note: Recorders did not pick up introduction of panel (see biographies for details on the panelists) or introduction of session.] Adam: Microphone. So, we've lost a little bit of time because of all of the sessions running a bit over, but here is

  6. I. V. Khalzov, B. P. Brown, F. Ebrahimi, D. D. Schnack, and C. B. Forest

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    simulation of laminar plasma dynamos in a cylindrical von Kármán flow I. V. Khalzov, B. P. Brown, F. Ebrahimi, D. D. Schnack, and C. B. Forest Citation: Phys. Plasmas 18, 032110 (2011); doi: 10.1063/1.3559472 View online: http://dx.doi.org/10.1063/1.3559472 View Table of Contents: http://pop.aip.org/resource/1/PHPAEN/v18/i3 Published by the American Institute of Physics. Additional information on Phys. Plasmas Journal Homepage: http://pop.aip.org/ Journal Information:

  7. I. V. Khalzov, B. P. Brown, N. Katz, and C. B. Forest

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    the Parker instability in a rotating plasma screw pinch I. V. Khalzov, B. P. Brown, N. Katz, and C. B. Forest Citation: Phys. Plasmas 19, 022107 (2012); doi: 10.1063/1.3684240 View online: http://dx.doi.org/10.1063/1.3684240 View Table of Contents: http://pop.aip.org/resource/1/PHPAEN/v19/i2 Published by the American Institute of Physics. Additional information on Phys. Plasmas Journal Homepage: http://pop.aip.org/ Journal Information: http://pop.aip.org/about/about_the_journal Top downloads:

  8. ,"Housing Units1","Average Square Footage Per Housing Unit",...

    Energy Information Administration (EIA) (indexed site)

    ... Vacant housing units, seasonal units, second homes, military housing, and group quarters are excluded. 2Total square footage includes all basements, finished or conditioned (heated ...

  9. Brown - leaves

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    Oct 14 th * Award decision by Nov 6 th * Presentation of New Program Thurs, Nov 13 th . * Utility opt-in Nov 7 - Dec 5 th * New program launch - April 1, 2015 12 B O N N E V I L L...

  10. Brown - leaves

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    and Opportunities Low Income Energy Efficiency Workgroup November 6, 2014 Sarah F. Moore, Residential Lead Courtney Dale, Residential Weatherization B O N N E V I L L E P O W...

  11. Relation between combustion heat and chemical wood composition during white and brown rot

    SciTech Connect

    Dobry, J.; Dziurzynski, A.; Rypacek, V.

    1986-01-01

    Samples of beech and spruce wood were incubated with the white rot fungi Pleurotus ostreatus and Lentinus tigrinus and the brown rot fungi Fomitopsis pinicola and Serpula lacrymans (S. lacrimans) for four months. Decomposition (expressed as percent weight loss) and amounts of holocellulose, lignin, humic acids (HU), hymatomelanic acids (HY) and fulvo acids (FU) were determined and expressed in weight percent. Combustion heat of holocellulose and lignin was determined in healthy wood and in specimens where decomposition was greater than 50%. During white rot decomposition, combustion heat was unchanged even at high decomposition and the relative amounts of holocellulose and lignin remained the same. Total amounts of HU, HY and FU increased during the initial stages and stabilized at 20%. The content of HU plus HY was negligible even at the highest degree of decomposition. During brown rot decomposition, combustion heat was unchanged only in the initial stages, it increased continously with increasing rot. Lignin content was unchanged in the initial stages and increased after 30% weight loss. Total amounts of HU, HY and FU increased continuously, reaching higher values than in white rot decomposition; there were differences between the two species. Biosynthesis of HU plus HY began when weight loss reached 30%; there were differences in absolute and relative amounts between species. 24 references.

  12. Isolation of laccase gene-specific sequences from white rot and brown rot fungi by PCR

    SciTech Connect

    D`Souza, T.M.; Boominathan, K.; Reddy, C.A.

    1996-10-01

    Degenerate primers corresponding to the consensus sequences of the copper-binding regions in the N-terminal domains of known basidiomycete laccases were used to isolate laccase gene-specific sequences from strains representing nine genera of wood rot fungi. All except three gave the expected PCR product of about 200 bp. Computer searches of the databases identified the sequences of each of the PCR product of about 200 bp. Computer searches of the databases identified the sequence of each of the PCR products analyzed as a laccase gene sequence, suggesting the specificity of the primers. PCR products of the white rot fungi Ganoderma lucidum, Phlebia brevispora, and Trametes versicolor showed 65 to 74% nucleotide sequence similarity to each other; the similarity in deduced amino acid sequences was 83 to 91%. The PCR products of Lentinula edodes and Lentinus tigrinus, on the other hand, showed relatively low nucleotide and amino acid similarities (58 to 64 and 62 to 81%, respectively); however, these similarities were still much higher than when compared with the corresponding regions in the laccases of the ascomycete fungi Aspergillus nidulans and Neurospora crassa. A few of the white rot fungi, as well as Gloeophyllum trabeum, a brown rot fungus, gave a 144-bp PCR fragment which had a nucleotide sequence similarity of 60 to 71%. Demonstration of laccase activity in G. trabeum and several other brown rot fungi was of particular interest because these organisms were not previously shown to produce laccases. 36 refs., 6 figs., 2 tabs.

  13. A HYBRID SCENARIO FOR THE FORMATION OF BROWN DWARFS AND VERY LOW MASS STARS

    SciTech Connect

    Basu, Shantanu; Vorobyov, Eduard I. E-mail: eduard.vorobiev@univie.ac.at

    2012-05-01

    We present a calculation of protostellar disk formation and evolution in which gaseous clumps (essentially, the first Larson cores formed via disk fragmentation) are ejected from the disk during the early stage of evolution. This is a universal process related to the phenomenon of ejection in multiple systems of point masses. However, it occurs in our model entirely due to the interaction of compact, gravitationally bound gaseous clumps and is free from the smoothing-length uncertainty that is characteristic of models using sink particles. Clumps that survive ejection span a mass range of 0.08-0.35 M{sub Sun }, and have ejection velocities 0.8 {+-} 0.35 km s{sup -1}, which are several times greater than the escape speed. We suggest that, upon contraction, these clumps can form substellar or low-mass stellar objects with notable disks, or even close-separation very low mass binaries. In this hybrid scenario, allowing for ejection of clumps rather than finished protostars/proto-brown-dwarfs, disk formation and the low velocity dispersion of low-mass objects are naturally explained, while it is also consistent with the observation of isolated low-mass clumps that are ejection products. We conclude that clump ejection and the formation of isolated low-mass stellar and substellar objects is a common occurrence, with important implications for understanding the initial mass function, the brown dwarf desert, and the formation of stars in all environments and epochs.

  14. DISCOVERY OF A ?250 K BROWN DWARF AT 2 pc FROM THE SUN

    SciTech Connect

    Luhman, K. L.

    2014-05-10

    Through a previous analysis of multi-epoch astrometry from the Wide-field Infrared Survey Explorer (WISE), I identified WISE J085510.83071442.5 as a new high proper motion object. By combining astrometry from WISE and the Spitzer Space Telescope, I have measured a proper motion of 8.1 0.1'' yr{sup 1} and a parallax of 0.454 0.045'' (2.20{sub ?0.20}{sup +0.24} pc) for WISE J085510.83071442.5, giving it the third highest proper motion and the fourth largest parallax of any known star or brown dwarf. It is also the coldest known brown dwarf based on its absolute magnitude at 4.5 ?m and its color in [3.6]-[4.5]. By comparing M {sub 4.5} with the values predicted by theoretical evolutionary models, I estimate an effective temperature of 225-260 K and a mass of 3-10 M {sub Jup} for the age range of 1-10 Gyr that encompasses most nearby stars.

  15. United States Environmental Monitoring

    Office of Legacy Management (LM)

    EPA 60014-91/030 Environmental Protection Systems Laboratory DOE/DP00539-063 Agency P.O. Box 93478 Las Vegas NV 891 93-3478 Research and Development Offsite Environmental Monitoring Report: 1 - 3 5 Radiation Monitorina Around * / (- P 7 1 United States ~ u c l g a r Test Areas Calendar Year 1990 This page intentionally left blank EPN60014-90 DOWDP Offsite Environmental Monitoring Report: Radiation Monitoring Around United States Nuclear Test Areas, Calendar Year 1990 Contributors: D.J. Chaloud,

  16. TRW utility demonstration unit

    SciTech Connect

    Not Available

    1990-01-01

    The TRW Advanced Entrained Coal Combustor Demonstration Project consists of retrofitting Orange and Rockland (O R) Utility Corporation's Lovett Plant Unit No. 3 with four (4) slagging combustors which will allow the gas/oil unit to fire 2.5% sulfur coal. The slagging combustor process will provide NO{sub x} and SO{sub x} emissions that meet NSPS and New York State Environmental Standards. During this report period, activity continued to address the total program funding shortfall. Ideas and responsibilities for further evaluation have been put forward to reduce the shortfall. In addition, an effort aimed at gaining additional program sponsorships, was initiated.

  17. Next Generation Rooftop Unit

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Next Generation Rooftop Unit - CRADA Bo Shen Oak Ridge National Laboratory shenb@ornl.gov; 865-574-5745 April 3, 2013 ET R&D project in support of DOE/BTO Goal of 50% Reduction in Building Energy Use by 2030. CRADA project with Trane TOP US Commercial HVAC Equipment OEM 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: half of all US commercial floor space cooled by packaged AC units, consumes more than 1.0 Quad source energy/year; highly efficient

  18. United Nations | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    United Nations Interregional Crime and Justice Research Institute (UNICRI) United Nations International Research and Training Institute for the Advancement of Women (UN-INSTRAW)...

  19. Thermal insulated glazing unit

    DOEpatents

    Selkowitz, S.E.; Arasteh, D.K.; Hartmann, J.L.

    1988-04-05

    An improved insulated glazing unit is provided which can attain about R5 to about R10 thermal performance at the center of the glass while having dimensions about the same as those of a conventional double glazed insulated glazing unit. An outer glazing and inner glazing are sealed to a spacer to form a gas impermeable space. One or more rigid, non-structural glazings are attached to the inside of the spacer to divide the space between the inner and outer glazings to provide insulating gaps between glazings of from about 0.20 inches to about 0.40 inches. One or more glazing surfaces facing each thermal gap are coated with a low emissivity coating. Finally, the thermal gaps are filled with a low conductance gas such as krypton gas. 2 figs.

  20. Thermal insulated glazing unit

    DOEpatents

    Selkowitz, Stephen E. (Piedmont, CA); Arasteh, Dariush K. (Oakland, CA); Hartmann, John L. (Seattle, WA)

    1991-01-01

    An improved insulated glazing unit is provided which can attain about R5 to about R10 thermal performance at the center of the glass while having dimensions about the same as those of a conventional double glazed insulated glazing unit. An outer glazing and inner glazing are sealed to a spacer to form a gas impermeable space. One or more rigid, non-structural glazings are attached to the inside of the spacer to divide the space between the inner and outer glazings to provide insulating gaps between glazings of from about 0.20 inches to about 0.40 inches. One or more glazing surfaces facing each thermal gap are coated with a low emissivity coating. Finally, the thermal gaps are filled with a low conductance gas such as krypton gas.

  1. Contamination analysis unit

    DOEpatents

    Gregg, Hugh R.; Meltzer, Michael P.

    1996-01-01

    The portable Contamination Analysis Unit (CAU) measures trace quantifies of surface contamination in real time. The detector head of the portable contamination analysis unit has an opening with an O-ring seal, one or more vacuum valves and a small mass spectrometer. With the valve closed, the mass spectrometer is evacuated with one or more pumps. The O-ring seal is placed against a surface to be tested and the vacuum valve is opened. Data is collected from the mass spectrometer and a portable computer provides contamination analysis. The CAU can be used to decontaminate and decommission hazardous and radioactive surface by measuring residual hazardous surface contamination, such as tritium and trace organics It provides surface contamination data for research and development applications as well as real-time process control feedback for industrial cleaning operations and can be used to determine the readiness of a surface to accept bonding or coatings.

  2. Contamination analysis unit

    DOEpatents

    Gregg, H.R.; Meltzer, M.P.

    1996-05-28

    The portable Contamination Analysis Unit (CAU) measures trace quantities of surface contamination in real time. The detector head of the portable contamination analysis unit has an opening with an O-ring seal, one or more vacuum valves and a small mass spectrometer. With the valve closed, the mass spectrometer is evacuated with one or more pumps. The O-ring seal is placed against a surface to be tested and the vacuum valve is opened. Data is collected from the mass spectrometer and a portable computer provides contamination analysis. The CAU can be used to decontaminate and decommission hazardous and radioactive surfaces by measuring residual hazardous surface contamination, such as tritium and trace organics. It provides surface contamination data for research and development applications as well as real-time process control feedback for industrial cleaning operations and can be used to determine the readiness of a surface to accept bonding or coatings. 1 fig.

  3. Laser system preset unit

    DOEpatents

    Goodwin, William L.

    1977-01-01

    An electronic circuit is provided which may be used to preset a digital display unit of a Zeeman-effect layer interferometer system which derives distance measurements by comparing a reference signal to a Doppler signal generated at the output of the interferometer laser head. The circuit presets dimensional offsets in the interferometer digital display by electronically inducing a variation in either the Doppler signal or the reference signal, depending upon the direction of the offset, to achieve the desired display preset.

  4. UNITED STATES GOVERNMENT

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    United states government department of energy ____________________________________________________________________________ ___ CONFERENCE CALL DOE FEDERAL LABOR FORUM PRELIMINARY MEETING AENDA August 9, 2013 @ 11:00 A.M. EDT Agenda: Confirm interest in DOE-wide labor forum Scope of Forum: This federal labor forum will be charged with jointly identifying and crafting recommended solutions to the problems facing us as a Department. The forum will accomplish this by using a constructive and

  5. United States Senate

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    from The Department of Energy for Committee on Energy and Natural Resources United States Senate S. 3312 - The Responsible Disposal Reauthorization Act of 2016 September 22, 2016 The Department of Energy, Office of Legacy Management (DOE-LM) has no issues with the intent of the Responsible Disposal Reauthorization Act of 2016 to extend the operating life of the Grand Junction Disposal Site from the year 2023 to 2048. The disposal site is located about 18 miles southeast of the City of Grand

  6. United States Government

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    * (08-93) United States Government Department of Energy Memorandum OFFICE OF INSPECTOR GENERAL DATE: November 9, 2005 REPLY TO ATTN OF: IG-34 (A05TG036) Audit Report No.: OAS-L-06-01 SUBJECT: Report on Audit of "The Department of Energy's Radio Communications Systems" TO: Chief Information Officer, IM-1 INTRODUCTION AND OBJECTIVE The Department of Energy's (Department) complex-wide radio systems infrastructure supports and facilitates activities such as site emergency response,

  7. Good Energies (United Kingdom) | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Energies (United Kingdom) Jump to: navigation, search Logo: Good Energies (United Kingdom) Name: Good Energies (United Kingdom) Address: 2-5 Old Bond Street Place: London, United...

  8. MICROLENSING DISCOVERY OF A POPULATION OF VERY TIGHT, VERY LOW MASS BINARY BROWN DWARFS

    SciTech Connect

    Choi, J.-Y.; Han, C.; Udalski, A.; Sumi, T.; Gaudi, B. S.; Gould, A.; Bennett, D. P.; Dominik, M.; Beaulieu, J.-P.; Tsapras, Y.; Bozza, V.; Abe, F.; Furusawa, K.; Itow, Y.; Bond, I. A.; Ling, C. H.; Botzler, C. S.; Freeman, M.; Chote, P.; Fukui, A.; Collaboration: MOA Collaboration; OGLE Collaboration; muFUN Collaboration; MiNDSTEp Consortium; PLANET Collaboration; RoboNet Collaboration; and others

    2013-05-10

    Although many models have been proposed, the physical mechanisms responsible for the formation of low-mass brown dwarfs (BDs) are poorly understood. The multiplicity properties and minimum mass of the BD mass function provide critical empirical diagnostics of these mechanisms. We present the discovery via gravitational microlensing of two very low mass, very tight binary systems. These binaries have directly and precisely measured total system masses of 0.025 M{sub Sun} and 0.034 M{sub Sun }, and projected separations of 0.31 AU and 0.19 AU, making them the lowest-mass and tightest field BD binaries known. The discovery of a population of such binaries indicates that BD binaries can robustly form at least down to masses of {approx}0.02 M{sub Sun }. Future microlensing surveys will measure a mass-selected sample of BD binary systems, which can then be directly compared to similar samples of stellar binaries.

  9. Extensive sampling of basidiomycete genomes demonstrates inadequacy of the white rot/ brown rot paradigm for wood decay fungi

    SciTech Connect

    Riley, Robert; Salamov, Asaf; Brown, Daren W.; Nagy, Laszlo G.; Floudas, Dimitris; Held, Benjamin; Levasseur, Anthony; Lombard, Vincent; Morin, Emmanuelle; Otillar, Robert; Lindquist, Erika; Sun, Hui; LaButti, Kurt; Schmutz, Jeremy; Jabbour, Dina; Luo, Hong; Baker, Scott E.; Pisabarro, Antonio; Walton, Jonathan D.; Blanchette, Robert; Henrissat, Bernard; Martin, Francis; Cullen, Dan; Hibbett, David; Grigoriev, Igor V.

    2014-03-14

    Basidiomycota (basidiomycetes) make up 32percent of the described fungi and include most wood decaying species, as well as pathogens and mutualistic symbionts. Wood-decaying basidiomycetes have typically been classified as either white rot or brown rot, based on the ability (in white rot only) to degrade lignin along with cellulose and hemicellulose. Prior genomic comparisons suggested that the two decay modes can be distinguished based on the presence or absence of ligninolytic class II peroxidases (PODs), as well as the abundance of enzymes acting directly on crystalline cellulose (reduced in brown rot). To assess the generality of the white rot/brown rot classification paradigm we compared the genomes of 33 basidiomycetes, including four newly sequenced wood decayers, and performed phylogenetically-informed Principal Components Analysis (PCA) of a broad range of gene families encoding plant biomass-degrading enzymes. The newly sequenced Botryobasidium botryosum and Jaapia argillacea genomes lack PODs, but possess diverse enzymes acting on crystalline cellulose, and they group close to the model white rot species Phanerochaete chrysosporium in the PCA. Furthermore, laboratory assays showed that both B. botryosum and J. argillacea can degrade all polymeric components of woody plant cell walls, a characteristic of white rot. We also found expansions in reducing polyketide synthase genes specific to the brown rot fungi. Our results suggest a continuum rather than a dichotomy between the white rot and brown rot modes of wood decay. A more nuanced categorization of rot types is needed, based on an improved understanding of the genomics and biochemistry of wood decay.

  10. Highly functionalized organic nitrates in the southeast United...

    Office of Scientific and Technical Information (OSTI)

    ; Brown, Steven S. more ; Koss, Abigail ; de Gouw, Joost ; Olson, Kevin ; Goldstein, Allen H. ; Seco, Roger ; Kim, Saewung ; McAvey, Kevin ; Shepson, Paul B. ; Starn, Tim ; ...

  11. Decommissioning Unit Cost Data

    SciTech Connect

    Sanford, P. C.; Stevens, J. L.; Brandt, R.

    2002-02-26

    The Rocky Flats Closure Site (Site) is in the process of stabilizing residual nuclear materials, decommissioning nuclear facilities, and remediating environmental media. A number of contaminated facilities have been decommissioned, including one building, Building 779, that contained gloveboxes used for plutonium process development but did little actual plutonium processing. The actual costs incurred to decommission this facility formed much of the basis or standards used to estimate the decommissioning of the remaining plutonium-processing buildings. Recent decommissioning activities in the first actual production facility, Building 771, implemented a number of process and procedural improvements. These include methods for handling plutonium contaminated equipment, including size reduction, decontamination, and waste packaging, as well as management improvements to streamline planning and work control. These improvements resulted in a safer working environment and reduced project cost, as demonstrated in the overall project efficiency. The topic of this paper is the analysis of how this improved efficiency is reflected in recent unit costs for activities specific to the decommissioning of plutonium facilities. This analysis will allow the Site to quantify the impacts on future Rocky Flats decommissioning activities, and to develop data for planning and cost estimating the decommissioning of future facilities. The paper discusses the methods used to collect and arrange the project data from the individual work areas within Building 771. Regression and data correlation techniques were used to quantify values for different types of decommissioning activities. The discussion includes the approach to identify and allocate overall project support, waste management, and Site support costs based on the overall Site and project costs to provide a ''burdened'' unit cost. The paper ultimately provides a unit cost basis that can be used to support cost estimates for

  12. United States Government

    Office of Legacy Management (LM)

    . v-w. ' ;H; (07.901 United States Government 0' ; Td 2, <.<~ Department of Energy ' m e m o randum DATE: REPLY TO Al-TN OF: EM-421 (W. A. W illiams, 903-8149) SUBJECT: Authorization for Remedial Action at Alba Craft Laboratory in Oxford, Ohio L. Price, OR TO: The former Alba Craft Laboratory site at lo-14 West Rose Avenue, Oxford, Ohio, is designated for remedial action under the Formerly Utilized Sites Remedial Action Program (FUSRAP). Dr. and M rs. Gilbert Pacey, of Oxford, Ohio, own

  13. United States Government

    Office of Legacy Management (LM)

    UOEF 1325.8 (5831 , - a.. L . . L. . c ,, . . . t ,' <, .* -,. .--1^ a "-2 (J 7 , pe-;L, United States Government memorandum Departmen: of Energy DATEAUG 1 0 1984 REPLY TO Al-fN OF: NE-20 SUBJECT: Action Description Memorandum (ADM) Review: Wayne, New Jersey Proposed 1984 Remedial Actions at TO: File After reviewing all of the pertinent facts including the attached Action Description Memorandum (ADM), I have determined that the remedial action described in the subject ADM is an action

  14. United States Government DATE:

    Office of Legacy Management (LM)

    5oE(E;,8 ' 0 H .2+ L-1 United States Government DATE: MAR 0 8 1994 REPLY TO AlTN OF: EM-421 (W. A. Williams, 903-8149) SUBJECT: Authority Determination -- Former Herring-Hall-Marvin Safe Co., Hamilton, Ohio TO: The File The attached review documents the basis for determining whether the Department of Energy (DOE) has authority for taking remedial action at the former Herring-Hall-Marvin Safe Co. facility in Hamilton, Ohio, under the Formerly Utilized Sites Remedial Action Program (FUSRAP). The

  15. United States Government

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    DOEF 1325.8 {Rev 11*12-91) United States Government Department of Energy (DOE) memorandum Savannah River Operations Office (SR) DATE: OEC 19 2013 REPLY TO ATTN OF: AMMS (Hintze, 803-952-8422) suBJECT: Savannah River Remediation (SRR) Award Fee Determination for Evaluation Period October 1, 2012 to September 30, 2013 To: Charlene Smith, Contracting Officer, Contract DE-AC09-09SR22505 SRR has provided safe, timely, and cost-effective managen1ent and execution of the Liquid Waste program* at the

  16. United States Government

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    30/02 WED 09:58 FAX 423 241 3897 OIG -.- +-+ HQ ]002 rFG (07-;1) United States Government Department of Energy Memorandum DATE: October 29, 2002 REPLY TO 1G-36 (A02DN028) Audit Report No.: OAS-L-03-01 ATTN OF; SUBJECT: Audit of Procurement at the Rocky Flats Environmental Technology Site TO: Eugene Schmitt, Manager, Rocky Flats Field Office ' INTRODUCTION AND OBJECTIVE The Department of Energy (Department) and its site contractor, Kaiser-Hill Company, LLC (Kaiser-Hill), contracted in January

  17. United States Government

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    03/02 TUE 08:59 FAX 423 241 3897 OIG *-* HQ 00o2 DOE F 132,.8 W.I: ((07.9u) United States Government Department of Energy Memorandum DATE: December 2, 2002 REPLY TO REPLY TO -36 (A02SR013) Audit Report No.: OAS-L-03-07 ATTN OF: SUBJECT: Audit of Subcontracting Practices at the Savannah River Site TO: Jeffrey M. Allison, Acting Manager, Savannah River Operations Office INTRODUCTION AND OBJECTIVE The Department of Energy (Department) has contracted with Westinghouse Savannah River Company, LLC

  18. United States Government

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    7/03 FRI 08:50 FAX 865 576 3213 OAK RIDGE AUDIT -+44 AIGA o001 10/16/03. THU 15:52 FAX 423 241 3897 OIG -- * ELMORE I001 United States Government Department of Eney memorandum DATE: October 1.6, 2003 b REPLY TO ATTNTO: IG-36 (A030R013) Audit Report No.: OAS-L-04-02 SUBJECT: Waste Pits and Silos Remediation at the Femald Closure Project To: Robert Wazther, Manager, Ohio Field Office INTRODUCTION AND OBJECTIVF In November 2000, the Ohio Field Office awarded a contract to Fluor Fernald Inc.,

  19. United States Government

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    .. a . r-z . "*& ., . .. uoi UA o. --.- flI gj UUX DOE F 1325.8 (08.93) United States Government Department of Ene memorandum DATE: August 19, 2004 Audit Report Number: OAS-L-04-18 REPLY TO ATTN OF: IG-36 (A03IF009) SUBJECT: Audit of the "Revised Pit 9 Cleanup Project at the Idaho National Engineering and Environmental Laboratory" TO: Paul Golan, Acting Assistant Secretary, Office of Environmental Management INTRODUCTION AND OBJECTIVE The Idaho National Engineering and

  20. United States Government

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    cr--ceut w.:3 i-Kun: TO:202 586 1660 P.002/006 DOE F 1325. EFG (07.PO) United States Government Department of Energy memorandum DATE: September 24, 2004 Audit Report Number: OAS-L-04-24 REPLY TO ATTN OF: IG-35 (A04AL004) SUBJECT: Audit Report on "The National Nuclear Security Administration's Secure Transportation Asset Program" TO: Deputy Administrator for Defense Programs, National Nuclear Security Administration INTRODUCTION AND OBIECTV E The Secure Transportation Asset (STA)

  1. United States Government

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    7325.8 (08-93) United States Government Department of Energy Memorandum DATE: October 30,2008 Audit Report Nuniber: OAS-L-09-01 REPLY TO AITN OF: IG-30 (A08GT053) SUBJECT: Audit Report on "Review of the Department of Energy's Contract with AHTNA Government Services Corporation Contract No: DE-AC52-04NA25282" TO: Director, Office of Field Financial Management, NNSA INTRODUCTION AND OBJECTIVE The National Nuclear Security Administration (NNSA) awarded a general construction contract to

  2. United States Government Departmen

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    7/05 TUE 07:58 FAX 423 241 3897 OIG -** HQ @]002 DOE F 1325.8 (08-93) United States Government Departmen of Energy memorandum DATE: December 20, 2005 Audit Report Number: OAS-L-06-03 REPLY TO A1TN OF; IG-36 (A05SR025) SUBJECT: Audit of "Defense Waste Processing Facility Operations at the Savannah River Site" TO: Jeffrey M. Allison, Manager, Savannah River Operations Office INTRODUCTION AND OBJECTIVE The Department of Energy's (Department) Savannah River Site stores approximately 36

  3. United States Government Department

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    B.89) EFO (07-90) United States Government Department of Energ Memorandum SEP 24 20t DATE: REPLY TO: IG-34 (A04TG032) Audit Report No.: OAS-L-04-21 SUBJECT: Evaluation of "The Federal Energy Regulatory Commission's Cyber Security Program - 2004" TO: Chairman, Federal Energy Regulatory Commission The purpose of this report is to inform you of the results of our annual evaluation of the Federal Energy Regulatory Commission's unclassified cyber security program. This evaluation was

  4. Energy Exchange Continuing Education Units

    Energy.gov [DOE]

    International Association for Continuing Education and Training (IACET) continuing education units (CEUs) will be available for designated training sessions.

  5. Monte Carlo Fundamentals E B. BROWN and T M. S N

    Office of Scientific and Technical Information (OSTI)

    or reflect those of the United States Government or any ... Monte Carlo approach: Generate a sequence of states, (pol ... partide from birth to death During the particle ...

  6. United States Government

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    11/07/03 13:UU FAA 301 903 4t00 UAI'I'AL REGION -+ tUK rlvrEA I(JUUZ DOE F 1325.8 (08-93) United States Government Department of Energy Memorandum OFFICE OF INSPECTOR GENERAL DATE: November 7, 2003 REPLY TO ATTN OF: IG-34 (A03SC050) Audit Report Number: OAS-L-04-04 SUBJECT: Audit of the U.S. Large Hadron Collider Program TO: Director, Office of Science, SC-1 The purpose of this report is to inform you of the results of our audit of the U.S. Large Hadron Collider (LHC) Program. The audit was

  7. Senior Obama Administration Officials to Join Governor Brown, Mayor Garcetti, Other Leaders in L.A. for Climate Task Force Meeting

    Energy.gov [DOE]

    On Thursday, February 13th, senior Obama Administration officials will join California Governor Jerry Brown, Los Angeles Mayor Eric Garcetti and state, local and tribal leaders from across the country for a media availability at Los Angeles City Hall

  8. PI3K/Akt is involved in brown adipogenesis mediated by growth differentiation factor-5 in association with activation of the Smad pathway

    SciTech Connect

    Hinoi, Eiichi; Iezaki, Takashi; Fujita, Hiroyuki; Watanabe, Takumi; Odaka, Yoshiaki; Ozaki, Kakeru; Yoneda, Yukio

    2014-07-18

    Highlights: • Akt is preferentially phosphorylated in BAT and sWAT of aP2-GDF5 mice. • PI3K/Akt signaling is involved in GDF5-induced brown adipogenesis. • PI3K/Akt signaling regulates GDF5-induced Smad5 phosphorylation. - Abstract: We have previously demonstrated promotion by growth differentiation factor-5 (GDF5) of brown adipogenesis for systemic energy expenditure through a mechanism relevant to activating the bone morphological protein (BMP) receptor/mothers against decapentaplegic homolog (Smad)/peroxisome proliferator-activated receptor gamma co-activator 1α (PGC-1α) pathway. Here, we show the involvement of the phosphatidylinositol 3-kinase (PI3K)/Akt pathway in brown adipogenesis mediated by GDF5. Overexpression of GDF5 in cells expressing adipocyte protein-2 markedly accelerated the phosphorylation of Smad1/5/8 and Akt in white and brown adipose tissues. In brown adipose tissue from heterozygous GDF5{sup Rgsc451} mutant mice expressing a dominant-negative (DN) GDF5 under obesogenic conditions, the basal phosphorylation of Smad1/5/8 and Akt was significantly attenuated. Exposure to GDF5 not only promoted the phosphorylation of both Smad1/5/8 and Akt in cultured brown pre-adipocytes, but also up-regulated Pgc1a and uncoupling protein-1 expression in a manner sensitive to the PI3K/Akt inhibitor Ly294002 as well as retroviral infection with DN-Akt. GDF5 drastically promoted BMP-responsive luciferase reporter activity in a Ly294002-sensitive fashion. Both Ly294002 and DN-Akt markedly inhibited phosphorylation of Smad5 in the nuclei of brown pre-adipocytes. These results suggest that PI3K/Akt signals play a role in the GDF5-mediated brown adipogenesis through a mechanism related to activation of the Smad pathway.

  9. Azimuthally sensitive hanbury brown-twiss interferometry in Au + Au collisions sqrt S sub NN = 200 GeV

    SciTech Connect

    Adams, J.; Adler, C.; Aggarwal, M.M.; Ahammed, Z.; Amonett, J.; Anderson, B.D.; Arkhipkin, D.; Averichev, G.S.; Badyal, S.K.; Balewski, J.; Barannikova, O.; Barnby, L.S.; Baudot, J.; Bekele, S.; Belaga, V.V.; Bellwied, R.; Berger, J.; Bezverkhny, B.I.; Bhardwaj, S.; Bhati, A.K.; Bichsel, H.; Billmeier, A.; Bland, L.C.; Blyth, C.O.; Bonner, B.E.; Botje, M.; Boucham, A.; Brandin, A.; Bravar, A.; Cadman, R.V.; Cai, X.Z.; Caines, H.; Calderon de la Barca Sanchez, M.; Carroll, J.; Castillo, J.; Cebra, D.; Chaloupka, P.; Chattopadhyay, S.; Chen, H.F.; Chen, Y.; Chernenko, S.P.; Cherney, M.; Chikanian, A.; Christie, W.; Coffin, J.P.; Cormier, T.M.; Cramer, J.G.; Crawford, H.J.; Das, D.; Das, S.; Derevschikov, A.A.; Didenko, L.; Dietel, T.; Dong, W.J.; Dong, X.; Draper, J.E.; Du, F.; Dubey, A.K.; Dunin, V.B.; Dunlop, J.C.; Dutta Majumdar, M.R.; Eckardt, V.; Efimov, L.G.; Emelianov, V.; Engelage, J.; Eppley, G.; Erazmus, B.; Estienne, M.; Fachini, P.; Faine, V.; Faivre, J.; Fatemi, R.; Filimonov, K.; Filip, P.; Finch, E.; Fisyak, Y.; Flierl, D.; Foley, K.J.; Fu, J.; Gagliardi, C.A.; Gagunashvili, N.; Gans, J.; Gaudichet, L.; Geurts, F.; Ghazikhanian, V.; Ghosh, P.; Gonzalez, J.E.; Grachov, O.; Grebenyuk, O.; Gronstal, S.; Grosnick, D.; Guertin, S.M.; Gupta, A.; Gutierrez, T.D.; Hallman, T.J.; Hamed, A.; Hardtke, D.; Harris, J.W.; Heinz, M.; Henry, T.W.; Heppelmann, S.; Hippolyte, B.; Hirsch, A.; Hjort, E.; Hoffmann, G.W.; Horsley, M.; Huang, H.Z.; Huang, L.S.; Hughes, E.; Humanic, T.J.; Igo, G.; Ishihara, A.; Jacobs, P.; Jacobs, W.W.; Janik, M.; Jiang, H.; Johnson, I.; Jones, P.G.; Judd, E.G.; Kabana, S.; Kaplan, M.; Keane, D.; Khodyrev, V.Yu.; Kiryluk, J.; Kisiel, A.; Klay, J.; Klein, S.R.; Klyachko, A.; Koetke, D.D.; Kollegger, T.; Kopytine, M.; Kotchenda, L.; Kovalenko, A.D.; Kramer, M.; Kravtsov, V.I.; Kravtsov, P.; Krueger, K.; Kuhn, C.; Kulikov, A.I.; Kumar, A.; Kunde, G.J.; Kunz, C.L.; Kutuev, R.Kh.; Kuznetsov, A.A.; Lamont, M.A.C.; et al.

    2004-06-30

    We present the results of a systematic study of the shape of the pion distribution in coordinate space at freeze-out in Au+Au collisions at RHIC using two-pion Hanbury Brown-Twiss (HBT) interferometry. Oscillations of the extracted HBT radii vs. emission angle indicate sources elongated perpendicular to the reaction plane. The results indicate that the pressure and expansion time of the collision system are not sufficient to completely quench its initial shape.

  10. Analysis of high-pressure boiloff situation during an MSIV closure ATWS in a typical BWR/4

    SciTech Connect

    Neymotin, L.Y.; Slovik, G.C.; Saha, P.

    1986-01-01

    An anticipated transient without scram (ATWS) is recognized as one of the boiling water reactor (BWR) accident sequences potentially leading to core damage. Of all the various ATWS initiating events, the main steam isolation valve (MSIV) closure ATWS is the most severe, because of its relatively high frequency of occurrence and its challenge to the residual heat removal and containment integrity systems. Although under investigation for quite a long period of time, different aspects of this type of transient are still being analyzed. The final outcome of these studies should be a well-defined set of recommendations for the plant operator to mitigate an ATWS accident. The objective of this paper is to provide a best estimate analysis of the MSIV closure ATWS in the Browns Ferry Unit 1 BWR with Mark-1 containment. The calculations have been performed using the RAMONA-3B code which as a three-dimensional neutron kinetics model coupled with one-dimensional four-equation, nonhomogeneous, nonequilibrium thermal hydraulics. The code also allows for one-dimensional neutronic core representation. The one-dimensional capability of the code has been employed in this calculation since a thorough sensitivity study showed that for a full ATWS, a one-dimensional neutron kinetics adequately describes the core behavior. The calculation described in the paper was started from a steady-state fuel condition corresponding to the end of cycle 5 of the Browns Ferry reactor.

  11. Effects of water hardness on the toxicity of manganese to developing brown trout (Salmo trutta)

    SciTech Connect

    Stubblefield, W.A.; Garrison, T.D.; Hockett, J.R.; Brinkman, S.F.; Davies, P.H.; McIntyre, M.W.

    1997-10-01

    Manganese is a common constituent of point and nonpoint discharges from mining and smelting activities. Available data indicate that Mn is acutely toxic at relatively high aqueous concentrations, when compared with trace metals, and its toxicity is affected by water hardness. Little information is available regarding the chronic toxicity of manganese. Early-life-stage (ELS) tests were conducted to determine the toxicity of manganese to brown trout (Salmo trutta) and to evaluate the extent to which water hardness (ranging from 30 to 450 mg/L as CaCO{sub 3}) affects the chronic toxicity of Mn. Water hardness of significantly affected Mn chronic toxicity, with toxicity decreasing with increasing hardness. Decreased survival was the predominant effect noted in the 30-mg/L hardness experiment, while significant effects on growth (as measured by changes in body weight) were observed in both the 150- and 450-mg/L hardness experiments. Twenty-five percent inhibition concentration (IC25) values, based on the combined endpoints (i.e., survival and body weight), were 4.67, 5.59, and 8.68 mg Mn/L (based on measured Mn concentration) at hardness levels of approximately 30, 150, and 450 mg/L as CaCO{sub 3}, respectively.

  12. Enhanced light absorption by mixed source black and brown carbon particles in UK winter

    DOE PAGES [OSTI]

    Liu, Shang; Aiken, Allison C.; Gorkowski, Kyle; Dubey, Manvendra K.; Cappa, Christopher D.; Williams, Leah R.; Herndon, Scott C.; Massoli, Paola; Fortner, Edward C.; Chhabra, Puneet S.; et al

    2015-09-30

    We report that black carbon (BC) and light-absorbing organic carbon (brown carbon, BrC) play key roles in warming the atmosphere, but the magnitude of their effects remains highly uncertain. Theoretical modelling and laboratory experiments demonstrate that coatings on BC can enhance BC’s light absorption, therefore many climate models simply assume enhanced BC absorption by a factor of ~1.5. However, recent field observations show negligible absorption enhancement, implying models may overestimate BC’s warming. Here we report direct evidence of substantial field-measured BC absorption enhancement, with the magnitude strongly depending on BC coating amount. Increases in BC coating result from a combinationmore » of changing sources and photochemical aging processes. When the influence of BrC is accounted for, observationally constrained model calculations of the BC absorption enhancement can be reconciled with the observations. In conclusion, we find that the influence of coatings on BC absorption should be treated as a source and regionally specific parameter in climate models.« less

  13. NEW BROWN DWARF COMPANIONS TO YOUNG STARS IN SCORPIUS-CENTAURUS

    SciTech Connect

    Janson, Markus; Jayawardhana, Ray; Bonavita, Mariangela; Girard, Julien H.; Lafreniere, David; Gizis, John; Brandeker, Alexis

    2012-10-10

    We present the discoveries of three faint companions to young stars in the Scorpius-Centaurus region, imaged with the NICI instrument on Gemini South. We have confirmed all three companions through common proper motion tests. Follow-up spectroscopy has confirmed two of them, HIP 65423 B and HIP 65517 B, to be brown dwarfs, while the third, HIP 72099 B, is more likely a very low mass star just above the hydrogen burning limit. The detection of wide companions in the mass range of {approx}40-100 M{sub jup} complements previous work in the same region, reporting detections of similarly wide companions with lower masses, in the range of {approx}10-30 M{sub jup}. Such low masses near the deuterium burning limit have raised the question of whether those objects formed like planets or stars. The existence of intermediate objects as reported here could represent a bridge between lower-mass companions and stellar companions, but in any case demonstrate that mass alone may not provide a clear-cut distinction for the formation of low-mass companions to stars.

  14. Characterization of novel sorghum brown midrib mutants from an EMS-mutagenized population

    DOE PAGES [OSTI]

    Sattler, Scott E.; Saballos, Ana; Xin, Zhanguo; Funnell-Harris, Deanna L.; Vermerris, Wilfred; Pedersen, Jeffrey F.

    2014-09-02

    Reducing lignin concentration in lignocellulosic biomass can increase forage digestibility for ruminant livestock and saccharification yields of biomass for bioenergy. In sorghum (Sorghum bicolor (L.) Moench) and several other C4 grasses, brown midrib (bmr) mutants have been shown to reduce lignin concentration. Putative bmr mutants isolated from an EMS-mutagenized population were characterized and classified based on their leaf midrib phenotype and allelism tests with the previously described sorghum bmr mutants bmr2, bmr6, and bmr12. These tests resulted in the identification of additional alleles of bmr2, bmr6,and bmr12, and, in addition, six bmr mutants were identified that were not allelic tomore » these previously described loci. Further allelism testing among these six bmr mutants showed that they represented four novel bmr loci. Based on this study, the number of bmr loci uncovered in sorghum has doubled. The impact of these lines on agronomic traits and lignocellulosic composition was assessed in a 2-yr field study. Most of the identified bmr lines showed reduced lignin concentration of their biomass relative to wild-type (WT). Effects of the six new bmr mutants on enzymatic saccharification of lignocellulosic materials were determined, but the amount of glucose released from the stover was similar to WT in all cases. Like bmr2, bmr6, and bmr12, these mutants may affect monolignol biosynthesis and may be useful for bioenergy and forage improvement when stacked together or in combination with the three previously described bmr alleles.« less

  15. Enhanced light absorption by mixed source black and brown carbon particles in UK winter

    SciTech Connect

    Liu, Shang; Aiken, Allison C.; Gorkowski, Kyle; Dubey, Manvendra K.; Cappa, Christopher D.; Williams, Leah R.; Herndon, Scott C.; Massoli, Paola; Fortner, Edward C.; Chhabra, Puneet S.; Brooks, William A.; Onasch, Timothy B.; Jayne, John T.; Worsnop, Douglas R.; China, Swarup; Sharma, Noopur; Mazzoleni, Claudio; Xu, Lu; Ng, Nga L.; Liu, Dantong; Allan, James D.; Lee, James D.; Fleming, Zoë L.; Mohr, Claudia; Zotter, Peter; Szidat, Sönke; Prévôt, André S. H.

    2015-09-30

    We report that black carbon (BC) and light-absorbing organic carbon (brown carbon, BrC) play key roles in warming the atmosphere, but the magnitude of their effects remains highly uncertain. Theoretical modelling and laboratory experiments demonstrate that coatings on BC can enhance BC’s light absorption, therefore many climate models simply assume enhanced BC absorption by a factor of ~1.5. However, recent field observations show negligible absorption enhancement, implying models may overestimate BC’s warming. Here we report direct evidence of substantial field-measured BC absorption enhancement, with the magnitude strongly depending on BC coating amount. Increases in BC coating result from a combination of changing sources and photochemical aging processes. When the influence of BrC is accounted for, observationally constrained model calculations of the BC absorption enhancement can be reconciled with the observations. In conclusion, we find that the influence of coatings on BC absorption should be treated as a source and regionally specific parameter in climate models.

  16. Spitzer IRAC mid-infrared photometry of 500-750 brown dwarf

    SciTech Connect

    Saumon, Didier; Leggett, Sandy K; Albert, Loic; Artigau, Etienne; Burningham, Ben; Delfosse, Xavier; Delorme, Philippe; Forveille, Thierry; Lucas, Philip W; Marley, Mark S; Pinfield, David J; Reyle, Celine; Smart, Richard L; Warren, Stephen J

    2010-10-26

    Mid-infrared data, including Spitzer warm-IRAC [3.6] and [4.5] photometry, is critical for understanding the cold population of brown dwarfs now being found, objects which have more in common with planets than stars. As effective temperature (T{sub eff}) drops from 800K to 400K, the fraction of flux emitted beyond 3 {mu}m increases rapidly, from about 40% to > 75%. This rapid increase makes a color like H-[4.5] a very sensitive temperature indicator, and it can be combined with a gravity- and metallicity-sensitive color like H-K to constrain all three of these fundamental properties, which in turn gives us mass and age for these slowly cooling objects. Determination of mid-infrared color trends also allows better exploitation of the WISE mission by the community. We use new Spitzer Cycle 6 IRAC photometry, together with published data, to present trends of color with type for L0 to T10 dwarfs. We also use the atmospheric and evolutionary models of Saumon and Marley to investigate the masses and ages of 13 very late-type T dwarfs, which have H-[4.5] > 3.2 and T{sub eff} {approx} 500K to 750K.

  17. United sail windmill

    SciTech Connect

    Labrador, G.A.

    1988-07-12

    This windmill provides low cost energy out of the wind in the form of compressed air, etc, by maximizing wind-contact at the least cost construction and maintenance, at the least cost of project site - making the ''Output/Cost Ratio'' very high. This is done by making the sails very large using light fabrics with aluminum or bamboo frames forming a square face, supported by light strong ropes, by arranging the sails on a single file close to one after the other at erect posture free to clip to the right or to the left, forming a long procession line transverse to the wind which is in close loop with another long procession line parallel to it but moving to the opposite direction, to produce a very large windmill without the need of additional set up units of windmills; by carrying the large sails high about the ground for better wind-contact thru a two level Aerial Cable Railway by means of a deep-groove roller wheel attached to the top end and to the bottom end of each sail-mast; by separating the two parallel lines of sails at least 100 feet apart for better wind-contact thru the use of set of three Terminal Gear Wheels at a Half-Hexagonal formation that hold the end loops of the Power Cable Chain being tugged by each sail; by making the windmill work during strong winds and storing the energy in compressed air tunnels, elevated water.

  18. " Million U.S. Housing Units"

    Energy Information Administration (EIA) (indexed site)

    Units" ,,"UrbanRural Location (as Self-Reported)" ,"Housing Units (millions)" "Space ... ,,"RSEs for UrbanRural Location (as Self-Reported)" ,"RSEs for Housing Units " "Space ...

  19. Next Generation Rooftop Unit | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Emerging Technologies Next Generation Rooftop Unit Next Generation Rooftop Unit The U.S. Department of Energy is currently conducting research in a next generation rooftop unit ...

  20. United Biofuels | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Biofuels Jump to: navigation, search Name: United Biofuels Place: York, Pennsylvania Product: Waste and animal fats to biofuel producer, switched to animal fats from soy in fall of...

  1. New Mexico grape growers unite

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    New Mexico grape growers unite, increase production Grape Growers Association enlivens ... land, enlivens production, protects water rights for Northern New Mexico agriculturists. ...

  2. Ozone induces glucose intolerance and systemic metabolic effects in young and aged brown Norway rats

    SciTech Connect

    Bass, V.; Gordon, C.J.; Jarema, K.A.; MacPhail, R.C.; Cascio, W.E.; Phillips, P.M.; Ledbetter, A.D.; Schladweiler, M.C.; Andrews, D.; Miller, D.; Doerfler, D.L.; Kodavanti, U.P.

    2013-12-15

    Air pollutants have been associated with increased diabetes in humans. We hypothesized that ozone would impair glucose homeostasis by altering insulin signaling and/or endoplasmic reticular (ER) stress in young and aged rats. One, 4, 12, and 24 month old Brown Norway (BN) rats were exposed to air or ozone, 0.25 or 1.0 ppm, 6 h/day for 2 days (acute) or 2 d/week for 13 weeks (subchronic). Additionally, 4 month old rats were exposed to air or 1.0 ppm ozone, 6 h/day for 1 or 2 days (time-course). Glucose tolerance tests (GTT) were performed immediately after exposure. Serum and tissue biomarkers were analyzed 18 h after final ozone for acute and subchronic studies, and immediately after each day of exposure in the time-course study. Age-related glucose intolerance and increases in metabolic biomarkers were apparent at baseline. Acute ozone caused hyperglycemia and glucose intolerance in rats of all ages. Ozone-induced glucose intolerance was reduced in rats exposed for 13 weeks. Acute, but not subchronic ozone increased ?{sub 2}-macroglobulin, adiponectin and osteopontin. Time-course analysis indicated glucose intolerance at days 1 and 2 (2 > 1), and a recovery 18 h post ozone. Leptin increased day 1 and epinephrine at all times after ozone. Ozone tended to decrease phosphorylated insulin receptor substrate-1 in liver and adipose tissues. ER stress appeared to be the consequence of ozone induced acute metabolic impairment since transcriptional markers of ER stress increased only after 2 days of ozone. In conclusion, acute ozone exposure induces marked systemic metabolic impairments in BN rats of all ages, likely through sympathetic stimulation. - Highlights: Air pollutants have been associated with increased diabetes in humans. Acute ozone exposure produces profound metabolic alterations in rats. Age influences metabolic risk factors in aging BN rats. Acute metabolic effects are reversible and repeated exposure reduces these effects. Ozone metabolic effects

  3. ,"Housing Units1","Average Square Footage Per Housing Unit",...

    Energy Information Administration (EIA) (indexed site)

    ... U.S. Department of Energy's Office of Energy and Efficiency and Renewable Energy (EERE). 5Rented includes households that occupy their primary housing unit without payment of rent. ...

  4. Advanced Unit Commitment Strategies in the United States Eastern Interconnection

    SciTech Connect

    Meibom, P.; Larsen, H. V.; Barth, R.; Brand, H.; Tuohy, A.; Ela, E.

    2011-08-01

    This project sought to evaluate the impacts of high wind penetrations on the U.S. Eastern Interconnection and analyze how different unit commitment strategies may affect these impacts.

  5. Nuclear factor-?B is a common upstream signal for growth differentiation factor-5 expression in brown adipocytes exposed to pro-inflammatory cytokines and palmitate

    SciTech Connect

    Hinoi, Eiichi; Iezaki, Takashi; Ozaki, Kakeru; Yoneda, Yukio

    2014-10-03

    Highlights: GDF5 expression is up-regulated by IL-1?, TNF-? and palmitate in brown pre-adipocytes. NF-?B stimulates promoter activity and expression of GDF5 in brown pre-adipocytes. Recruitment of NF-?B to the GDF5 promoter is facilitated in BAT from ob/ob mice. An NF-?B inhibitor prevents upregulation of GDF5 expression in brown pre-adipocytes. - Abstract: We have previously demonstrated that genetic and acquired obesity similarly led to drastic upregulation in brown adipose tissue (BAT), rather than white adipose tissue, of expression of both mRNA and corresponding protein for the bone morphogenic protein/growth differentiation factor (GDF) member GDF5 capable of promoting brown adipogenesis. In this study, we evaluated expression profiles of GDF5 in cultured murine brown pre-adipocytes exposed to pro-inflammatory cytokines and free fatty acids (FFAs), which are all shown to play a role in the pathogenesis of obesity. Both interleukin-1? (IL-1?) and tumor necrosis factor-? (TNF-?) were effective in up-regulating GDF5 expression in a concentration-dependent manner, while similar upregulation was seen in cells exposed to the saturated FFA palmitate, but not to the unsaturated FFA oleate. In silico analysis revealed existence of the putative nuclear factor-?B (NF-?B) binding site in the 5?-flanking region of mouse GDF5, whereas introduction of NF-?B subunits drastically facilitated both promoter activity and expression of GDF5 in brown pre-adipocytes. Chromatin immunoprecipitation analysis confirmed significant facilitation of the recruitment of NF-?B to the GDF5 promoter in lysed extracts of BAT from leptin-deficient ob/ob obese mice. Upregulation o GDF5 expression was invariably inhibited by an NF-?B inhibitor in cultured brown pre-adipocytes exposed to IL-1?, TNF-? and palmitate. These results suggest that obesity leads to upregulation of GDF5 expression responsible for the promotion of brown adipogenesis through a mechanism relevant to activation of the

  6. A statistical analysis of seeds and other high-contrast exoplanet surveys: massive planets or low-mass brown dwarfs?

    SciTech Connect

    Brandt, Timothy D.; Spiegel, David S.; McElwain, Michael W.; Grady, C. A.; Turner, Edwin L.; Mede, Kyle; Kuzuhara, Masayuki; Schlieder, Joshua E.; Brandner, W.; Feldt, M.; Wisniewski, John P.; Abe, L.; Biller, B.; Carson, J.; Currie, T.; Egner, S.; Golota, T.; Guyon, O.; Goto, M.; Hashimoto, J.; and others

    2014-10-20

    We conduct a statistical analysis of a combined sample of direct imaging data, totalling nearly 250 stars. The stars cover a wide range of ages and spectral types, and include five detections (? And b, two ?60 M {sub J} brown dwarf companions in the Pleiades, PZ Tel B, and CD35 2722B). For some analyses we add a currently unpublished set of SEEDS observations, including the detections GJ 504b and GJ 758B. We conduct a uniform, Bayesian analysis of all stellar ages using both membership in a kinematic moving group and activity/rotation age indicators. We then present a new statistical method for computing the likelihood of a substellar distribution function. By performing most of the integrals analytically, we achieve an enormous speedup over brute-force Monte Carlo. We use this method to place upper limits on the maximum semimajor axis of the distribution function derived from radial-velocity planets, finding model-dependent values of ?30-100 AU. Finally, we model the entire substellar sample, from massive brown dwarfs to a theoretically motivated cutoff at ?5 M {sub J}, with a single power-law distribution. We find that p(M, a)?M {sup 0.65} {sup } {sup 0.60} a {sup 0.85} {sup } {sup 0.39} (1? errors) provides an adequate fit to our data, with 1.0%-3.1% (68% confidence) of stars hosting 5-70 M {sub J} companions between 10 and 100 AU. This suggests that many of the directly imaged exoplanets known, including most (if not all) of the low-mass companions in our sample, formed by fragmentation in a cloud or disk, and represent the low-mass tail of the brown dwarfs.

  7. I. V. Khalzov, B. P. Brown, E. J. Kaplan, N. Katz, C. Paz-Soldan et al.

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    Resistive and ferritic-wall plasma dynamos in a sphere I. V. Khalzov, B. P. Brown, E. J. Kaplan, N. Katz, C. Paz-Soldan et al. Citation: Phys. Plasmas 19, 104501 (2012); doi: 10.1063/1.4757219 View online: http://dx.doi.org/10.1063/1.4757219 View Table of Contents: http://pop.aip.org/resource/1/PHPAEN/v19/i10 Published by the American Institute of Physics. Additional information on Phys. Plasmas Journal Homepage: http://pop.aip.org/ Journal Information: http://pop.aip.org/about/about_the_journal

  8. United Cooperative | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    which agreed to purchase a former VeraSun Energy ethanol plant in Iowa from AgStar Financial Services in August 2009. References: United Cooperative1 This article is a...

  9. Direct Current's Energy Unit Calculator

    Energy.gov [DOE]

    We recently released the second episode of Direct Current, our new Energy.gov podcast. Check out our newly proposed energy units -- burritos, Mt. Rushmore, a New York Minute and the Moon Landing!

  10. United States Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    ... Quillen with relief that is equivalent to what he could receive under Part 708. 2 The parties to the settlement agreement were the United Steel, Paper and Forestry, Rubber, ...

  11. United States Electricity Industry Primer

    Office of Energy Efficiency and Renewable Energy (EERE)

    The United States Electricity Industry Primer provides a high-level overview of the U.S. electricity supply chain, including generation, transmission, and distribution; markets and ownership structures, including utilities and regulatory agencies; and system reliability and vulnerabilities.

  12. THE BROWN DWARF KINEMATICS PROJECT (BDKP). III. PARALLAXES FOR 70 ULTRACOOL DWARFS

    SciTech Connect

    Faherty, Jacqueline K.; Shara, Michael M.; Cruz, Kelle L.; Burgasser, Adam J.; Walter, Frederick M.; Van der Bliek, Nicole; Vrba, Frederick J.; Anglada-Escude, Guillem

    2012-06-10

    We report parallax measurements for 70 ultracool dwarfs (UCDs) including 11 late-M, 32 L, and 27 T dwarfs. In this sample, 14 M and L dwarfs exhibit low surface gravity features, 6 are close binary systems, and 2 are metal-poor subdwarfs. We combined our new measurements with 114 previously published UCD parallaxes and optical-mid-IR photometry to examine trends in spectral-type/absolute magnitude, and color-color diagrams. We report new polynomial relations between spectral type and M{sub JHK}. Including resolved L/T transition binaries in the relations, we find no reason to differentiate between a 'bright' (unresolved binary) and a 'faint' (single source) sample across the L/T boundary. Isolating early T dwarfs, we find that the brightening of T0-T4 sources is prominent in M{sub J} where there is a [1.2-1.4] mag difference. A similar yet dampened brightening of [0.3-0.5] mag happens at M{sub H} and a plateau or dimming of [-0.2 to -0.3] mag is seen in M{sub K} . Comparison with evolutionary models that vary gravity, metallicity, and cloud thickness verifies that for L into T dwarfs, decreasing cloud thickness reproduces brown dwarf near-IR color-magnitude diagrams. However we find that a near constant temperature of 1200 {+-}100 K along a narrow spectral subtype of T0-T4 is required to account for the brightening and color-magnitude diagram of the L-dwarf/T-dwarf transition. There is a significant population of both L and T dwarfs which are red or potentially 'ultra-cloudy' compared to the models, many of which are known to be young indicating a correlation between enhanced photospheric dust and youth. For the low surface gravity or young companion L dwarfs we find that 8 out of 10 are at least [0.2-1.0] mag underluminous in M{sub JH} and/or M{sub K} compared to equivalent spectral type objects. We speculate that this is a consequence of increased dust opacity and conclude that low surface gravity L dwarfs require a completely new spectral-type/absolute magnitude

  13. United States Environmental Monitoring EPA

    Office of Legacy Management (LM)

    United States Environmental Monitoring EPA 600/R-93/141 Environmental Protection Systems Laboratory January 1992 Agency P.O. Box 93478 Las Vegas NV 89193-3478 Research and Development _EPA Offsite Environmental Monitoring Report: Radiation Monitoring Around United States Nuclear Test Areas, Calendar Year 1991 Available to DOE and DOE contractors from the Office of Scientificand Technical Information, P.O. Box 62, Oak ridge,TN 39831; pricesavailablefrom (615) 576-8401 Availableto the publicfrom

  14. United Power, Inc | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    United Power, Inc Place: Colorado Website: unitedpower.com Twitter: @UnitedPowerCoop Facebook: https:www.facebook.comUnitedPower Outage Hotline: 1-303-637-1350 Outage Map:...

  15. The effects of overwinter flowson the spring condition of rainbow and brown trout size classes in the Green River downstream of Flaming Gorge Dam, Utah.

    SciTech Connect

    Magnusson, A. K.; LaGory, K. E.; Hayse, J. W.; Environmental Science Division

    2010-06-25

    Flaming Gorge Dam, a hydroelectric facility operated by the Bureau of Reclamation (Reclamation), is located on the Green River in Daggett County, northeastern Utah. Until recently, and since the early 1990s, single daily peak releases or steady flows have been the operational pattern of the dam during the winter period. However, releases from Flaming Gorge Reservoir followed a double-peak pattern (two daily flow peaks) during the winters of 2006-2007 and 2008-2009. Because there is little recent long-term history of double-peaking at Flaming Gorge Dam, the potential effects of double-peaking operations on trout body condition in the dam's tailwater are not known. A study plan was developed that identified research activities to evaluate potential effects from winter double-peaking operations (Hayse et al. 2009). Along with other tasks, the study plan identified the need to conduct a statistical analysis of historical trout condition and macroinvertebrate abundance to evaluate the potential effects of hydropower operations. The results from analyses based on the combined size classes of trout (85-630 mm) were presented in Magnusson et al. (2008). The results of this earlier analysis suggested possible relationships between trout condition and flow, but concern that some of the relationships resulted from size-based effects (e.g., apparent changes in condition may have been related to concomitant changes in size distribution, because small trout may have responded differently to flow than large trout) prompted additional analysis of within-size class relationships. This report presents the results of analyses of three different size classes of trout (small: 200-299 mm, medium: 300-399 mm, and large: {ge}400 mm body length). We analyzed historical data to (1) describe temporal patterns and relationships among flows, benthic macroinvertebrate abundance, and condition of brown trout (Salmo trutta) and rainbow trout (Oncorhynchus mykiss) in the tailwaters of Flaming

  16. UNITED STATES ENVIRONMENTAL PROTECTION AGENCY

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    e'-ä\r., a"àT#j UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGION 6 14,15 ROSS AVENUE, SUITE 1200 DALLAS, TX 752A2-n33 JA¡t 5 20ll cERTrrmD rytAlr- RETIIRN RECETPT REOITESIEn COPY Edward Ziemianski Acting Manager U.S. Department of Energy Carlsbad Field Offïce P.O. Box 3090 Carlsbad, NM 88221 RE: United States Environmental Protection Agency (EPA) Region 6 Response to the Waste Isolation Pilot Plant OVPP) Approval Request to Use Panel 8 to Store and Land Dispose Polychlorinated

  17. GEO UNIT AGREEMENT | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    GEO UNIT AGREEMENT Jump to: navigation, search GEO UNIT AGREEMENT Mineral interest joined together to explore, develop and produce geothermal resources Retrieved from "http:...

  18. Photovoltaics Economic Calculator (United States) | Open Energy...

    OpenEI (Open Energy Information) [EERE & EIA]

    (United States) Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Photovoltaics Economic Calculator (United States) Focus Area: Solar Topics: System & Application...

  19. Unit Energy Europe AG | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Wind energy Product: Unit Energy develops and operates wind parks and hydroelectric power plants all across Europe. References: Unit Energy Europe AG1 This article is a stub....

  20. Sunton United Energy LLC | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    United Energy LLC Jump to: navigation, search Name: Sunton United Energy LLC Place: Salt Lake City, Utah Sector: Renewable Energy Product: Utah-based investment company seeking...

  1. United Energy Group PLC | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Group PLC Jump to: navigation, search Name: United Energy Group PLC Place: Haslemere, United Kingdom Sector: Hydro, Wind energy Product: The company develops small hydro, gas...

  2. Biofuels Atlas (United States) | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Atlas (United States) Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Biofuels Atlas (United States) Focus Area: Clean Transportation Topics: Potentials & Scenarios...

  3. Low Carbon Transition Unit | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Transition Unit Jump to: navigation, search Name Low Carbon Transition Unit AgencyCompany Organization Danish Government Partner Danish Ministry of Climate, Energy and Buildings;...

  4. United Biofuels Private Limited | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    United Biofuels Private Limited Jump to: navigation, search Name: United Biofuels Private Limited Place: Tamil Nadu, India Sector: Biomass Product: India-based owner and operator...

  5. United Group Limited | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Limited Jump to: navigation, search Name: United Group Limited Place: Perth, Western Australia, Australia Zip: 6001 Product: The United Group Resources (UGL) division is an EPC and...

  6. United Nations Industrial Development Organization Feed | Open...

    OpenEI (Open Energy Information) [EERE & EIA]

    US Savannah River National Laboratory (SRNL) UNEP-Risoe Centre on Energy, Climate and Sustainable Development United Nations Environment Programme (UNEP) United Nations...

  7. United Nations Foundation Feed | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    US Savannah River National Laboratory (SRNL) UNEP-Risoe Centre on Energy, Climate and Sustainable Development United Nations Environment Programme (UNEP) United Nations...

  8. A CAUTIONARY TALE: MARVELS BROWN DWARF CANDIDATE REVEALS ITSELF TO BE A VERY LONG PERIOD, HIGHLY ECCENTRIC SPECTROSCOPIC STELLAR BINARY

    SciTech Connect

    Mack, Claude E. III; Stassun, Keivan G.; De Lee, Nathan; Ge, Jian; Fleming, Scott W.; Deshpande, Rohit; Mahadevan, Suvrath; Wisniewski, John P.; Gaudi, B. Scott; Eastman, Jason; Beatty, Thomas G.; Ghezzi, Luan; Gonzalez Hernandez, Jonay I.; Femenia, Bruno; Mata Sanchez, Daniel; Ferreira, Leticia; Porto de Mello, Gustavo; Crepp, Justin R.; Agol, Eric; Bizyaev, Dmitry; and others

    2013-05-15

    We report the discovery of a highly eccentric, double-lined spectroscopic binary star system (TYC 3010-1494-1), comprising two solar-type stars that we had initially identified as a single star with a brown dwarf companion. At the moderate resolving power of the MARVELS spectrograph and the spectrographs used for subsequent radial-velocity (RV) measurements (R {approx}< 30, 000), this particular stellar binary mimics a single-lined binary with an RV signal that would be induced by a brown dwarf companion (Msin i {approx} 50 M{sub Jup}) to a solar-type primary. At least three properties of this system allow it to masquerade as a single star with a very-low-mass companion: its large eccentricity (e {approx} 0.8), its relatively long period (P {approx} 238 days), and the approximately perpendicular orientation of the semi-major axis with respect to the line of sight ({omega} {approx} 189 Degree-Sign ). As a result of these properties, for {approx}95% of the orbit the two sets of stellar spectral lines are completely blended, and the RV measurements based on centroiding on the apparently single-lined spectrum is very well fit by an orbit solution indicative of a brown dwarf companion on a more circular orbit (e {approx} 0.3). Only during the {approx}5% of the orbit near periastron passage does the true, double-lined nature and large RV amplitude of {approx}15 km s{sup -1} reveal itself. The discovery of this binary system is an important lesson for RV surveys searching for substellar companions; at a given resolution and observing cadence, a survey will be susceptible to these kinds of astrophysical false positives for a range of orbital parameters. Finally, for surveys like MARVELS that lack the resolution for a useful line bisector analysis, it is imperative to monitor the peak of the cross-correlation function for suspicious changes in width or shape, so that such false positives can be flagged during the candidate vetting process.

  9. DOE Tour of Zero Floorplans: United Veterans Beacon House by United Way of

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Long Island | Department of Energy United Veterans Beacon House by United Way of Long Island DOE Tour of Zero Floorplans: United Veterans Beacon House by United Way of Long Island DOE Tour of Zero Floorplans: United Veterans Beacon House by United Way of Long Island

  10. Are green lots worth more than brown lots? An economic incentive for erosion control on residential developments

    SciTech Connect

    Herzog, M.; Harbor, J.; McClintock, K.; Law, J.; Bennett, K.

    2000-03-01

    Construction sites are major contributors to nonpoint source (NPS) pollution. However, a lack of personnel to enforce erosion control regulations and limited voluntary compliance means that few developers apply effective erosion control. New approaches are needed to increase erosion control on construction sites if this source of NPS pollution is to be significantly reduced. This study tests whether an economic advantage exists for developers who use vegetative cover for erosion control, independent of advantages gained in addressing environmental or regulatory concerns. Improving residential lot appearance from muddy brown to green grass may increase the appeal of the lot to buyers. A market survey shows that homebuyers and realtors perceive vegetated lots to be worth more than unvegetated lots, and this increased value exceeds the cost of seeding. Thus, developers can now be encouraged to invest in vegetative cover because of the potentially high return on the investment.

  11. Early anisotropic hydrodynamics and thermalization and Hanbury-Brown-Twiss puzzles in the BNL Relativistic Heavy Ion Collider (RHIC)

    SciTech Connect

    Ryblewski, Radoslaw; Florkowski, Wojciech

    2010-08-15

    We address the problem of whether the early thermalization and Hanbury-Brown-Twiss (HBT) puzzles in relativistic heavy-ion collisions may be solved by the assumption that the early dynamics of the produced matter is locally anisotropic. The hybrid model describing the purely transverse hydrodynamic evolution followed by the perfect-fluid hydrodynamic stage is constructed. The transition from the transverse to perfect-fluid hydrodynamics is described by the Landau matching conditions applied at a fixed proper time {tau}{sub tr}. The global fit to the RHIC data reproduces the soft hadronic observables (the pion, kaon, and the proton spectra, the pion and kaon elliptic flow, and the pion HBT radii) with the accuracy of about 20%. These results indicate that the assumption of the very fast thermalization may be relaxed. In addition, the presented model suggests that a large part of the inconsistencies between the theoretical and experimental HBT results may be removed.

  12. WISEP J004701.06+680352.1: AN INTERMEDIATE SURFACE GRAVITY, DUSTY BROWN DWARF IN THE AB DOR MOVING GROUP

    SciTech Connect

    Gizis, John E.; Allers, Katelyn N.; Liu, Michael C.; Harris, Hugh C.; Faherty, Jacqueline K.; Burgasser, Adam J.; Kirkpatrick, J. Davy

    2015-02-01

    We present spectroscopy, astrometry, and photometry of the brown dwarf WISEP J004701.06+680352.1 (W0047+68), an unusually red field L dwarf at a distance of 12.2 ± 0.4 pc. The three-dimensional space motion identifies it as a member of the AB Dor Moving Group, an identification supported by our classification of W0047+68 as intermediate surface gravity (INT-G) using the Allers and Liu near-infrared classification system. This moving group membership implies near-solar metallicity, age ∼100-125 Myr, M ≈ 0.018 M {sub ☉}, and log g ≈ 4.5; the thick condensate clouds needed to explain the infrared spectrum are, therefore, a result of surface gravity that is lower than that of ordinary field brown dwarfs. From the observed luminosity and evolutionary model radius, we find T {sub eff} ≈ 1300 K, a temperature normally associated with early T dwarfs. Thick clouds are also used to explain the spectral properties of directly imaged giant planets, and we discuss the successes and challenges for such substellar models in matching the observed optical and infrared spectra. W0047+68 shows that cloud thickness is more sensitive to intermediate surface gravity than in most models. We also present a trigonometric parallax of the dusty L6 dwarf 2MASS J21481628+4003593. It lies at 8.060 ± 0.036 parsecs; its astrometry is consistent with the view that it is older and metal-rich.

  13. ABPDU - Advanced Biofuels Process Demonstration Unit

    SciTech Connect

    2011-01-01

    Lawrence Berkeley National Lab opened its Advanced Biofuels Process Demonstration Unit on Aug. 18, 2011.

  14. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    Appliances in U.S. Homes, by Housing Unit Type, 2009" " Million Housing Units, Final" ,,"Housing Unit Type" ,,"Single-Family Units",,"Apartments in Buildings With" ,"Total U.S.1 (millions)" ,,,,,"5 or More Units","Mobile Homes" "Appliances",,"Detached","Attached","2 to 4 Units" "Total Homes",113.6,71.8,6.7,9,19.1,6.9 "Cooking Appliances" "Stoves (Units With

  15. 1997 Housing Characteristics Tables Housing Unit Tables

    Energy Information Administration (EIA) (indexed site)

    Million U.S. Households; 45 pages, 128 kb) Contents Pages HC1-1a. Housing Unit Characteristics by Climate Zone, Million U.S. Households, 1997 4 HC1-2a. Housing Unit Characteristics by Year of Construction, Million U.S. Households, 1997 4 HC1-3a. Housing Unit Characteristics by Household Income, Million U.S. Households, 1997 4 HC1-4a. Housing Unit Characteristics by Type of Housing Unit, Million U.S. Households, 1997 3 HC1-5a. Housing Unit Characteristics by Type of Owner-Occupied Housing Unit,

  16. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    2 Appliances in U.S. Homes, by Owner/Renter Status, 2009" " Million Housing Units, Final" ,,,,"Housing Unit Type" ,,,,"Single-Family Units",,,,"Apartments in Buildings With" ,"Total U.S.1 (millions)",,,"Detached",,"Attached",,"2 to 4 Units",,"5 or More Units",,"Mobile Homes"

  17. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    2 Televisions in U.S. Homes, by Owner/Renter Status, 2009" " Million Housing Units, Final" ,,,,"Housing Unit Type" ,,,,"Single-Family Units",,,,"Apartments in Buildings With" ,,,,"Detached",,"Attached",,"2 to 4 Units",,"5 or More Units",,"Mobile Homes" ,"Total U.S.1 (millions)"

  18. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    2 Water Heating in U.S. Homes, by Owner/Renter Status, 2009" " Million Housing Units, Final" ,,,,"Housing Unit Type" ,,,,"Single-Family Units",,,,"Apartments in Buildings With" ,"Total U.S.1 (millions)",,,"Detached",,"Attached",,"2 to 4 Units",,"5 or More Units",,"Mobile Homes"

  19. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    2 Computers and Other Electronics in U.S. Homes, by Owner/Renter Status, 2009" " Million Housing Units, Final" ,,,,"Housing Unit Type" ,,,,"Single-Family Units",,,,"Apartments in Buildings With" ,,,,"Detached",,"Attached",,"2 to 4 Units",,"5 or More Units",,"Mobile Homes" ,"Total U.S.1 (millions)"

  20. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    2 Air Conditioning in U.S. Homes, by Owner/Renter Status, 2009" " Million Housing Units, Final" ,,,,"Housing Unit Type" ,,,,"Single-Family Units",,,,"Apartments in Buildings With" ,,,,"Detached",,"Attached",,"2 to 4 Units",,"5 or More Units",,"Mobile Homes" ,"Total U.S.1 (millions)" "Air

  1. Waste management units - Savannah River Site

    SciTech Connect

    Not Available

    1989-10-01

    This report is a compilation of worksheets from the waste management units of Savannah River Plant. Information is presented on the following: Solid Waste Management Units having received hazardous waste or hazardous constituents with a known release to the environment; Solid Waste Management Units having received hazardous waste or hazardous constituents with no known release to the environment; Solid Waste Management Units having received no hazardous waste or hazardous constituents; Waste Management Units having received source; and special nuclear, or byproduct material only.

  2. United States Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    United States Department of Energy Office of Hearings and Appeals In the Matter of: Washington State ) Fleet Operations ) ) Filing Date: December 2, 2014 ) Case No.: AFV-14-0001 ____________________________________) Issued: December 18, 2014 _______________ Decision and Order _______________ This Decision and Order considers an Appeal filed by Washington State Fleet Operations (Washington) from a determination issued on November 10, 2014, by the Department of Energy's (DOE) Alternative Fuel

  3. United States Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    United States Department of Energy University of California Publication Date: May 2016 Capturing the Benefits of Integrated Resource Management for Water & Electricity Utilities and their Partners 2 EXECUTIVE SUMMARY The water and energy sectors have traditionally been studied independently, regulated by separate oversight agencies, and delivered to customers by separate utilities. Yet it is undeniable that there are strong interdependencies between the sectors. Water, in its many forms, has

  4. United States Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    United States Department of Energy Office of Hearings and Appeals In the Matter of ) ) Filing Date: October 27, 2016 ) Case No.: FIA-16-0053 ) _________________________________________ ) Issued: November 4, 2016 ______________________ Decision and Order ______________________ On October 27, 2016, (Appellant) appealed a determination received from the Department of Energy's (DOE) Oak Ridge Office (ORO) (Request No. ORO-2016-01447-F). In that determination, ORO responded to a request filed under

  5. Dixie Valley Bottoming Binary Unit

    SciTech Connect

    McDonald, Dale

    2014-12-21

    This binary plant is the first air cooled, high-output refrigeration based waste heat recovery cycle in the industry. Its working fluid is environmentally friendly and as such, the permits that would be required with a hydrocarbon based cycle are not necessary. The unit is largely modularized, meaning that the unit’s individual skids were assembled in another location and were shipped via truck to the plant site. The Air Cooled Condensers (ACC), equipment piping, and Balance of Plant (BOP) piping were constructed at site. This project further demonstrates the technical feasibility of using low temperature brine for geothermal power utilization. The development of the unit led to the realization of low temperature, high output, and environmentally friendly heat recovery systems through domestic research and engineering. The project generates additional renewable energy, resulting in cleaner air and reduced carbon dioxide emissions. Royalty and tax payments to governmental agencies will increase, resulting in reduced financial pressure on local entities. The major components of the unit were sourced from American companies, resulting in increased economic activity throughout the country.

  6. United States National Seismographic Network

    SciTech Connect

    Buland, R.

    1993-09-01

    The concept of a United States National Seismograph Network (USNSN) dates back nearly 30 years. The idea was revived several times over the decades. but never funded. For, example, a national network was proposed and discussed at great length in the so called Bolt Report (U. S. Earthquake Observatories: Recommendations for a New National Network, National Academy Press, Washington, D.C., 1980, 122 pp). From the beginning, a national network was viewed as augmenting and complementing the relatively dense, predominantly short-period vertical coverage of selected areas provided by the Regional Seismograph Networks (RSN`s) with a sparse, well-distributed network of three-component, observatory quality, permanent stations. The opportunity finally to begin developing a national network arose in 1986 with discussions between the US Geological Survey (USGS) and the Nuclear Regulatory Commission (NRC). Under the agreement signed in 1987, the NRC has provided $5 M in new funding for capital equipment (over the period 1987-1992) and the USGS has provided personnel and facilities to develop. deploy, and operate the network. Because the NRC funding was earmarked for the eastern United States, new USNSN station deployments are mostly east of 105{degree}W longitude while the network in the western United States is mostly made up of cooperating stations (stations meeting USNSN design goals, but deployed and operated by other institutions which provide a logical extension to the USNSN).

  7. The United States Code - Printing, Title 44 Excerpts | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    The United States Code - Printing, Title 44 Excerpts The United States Code - Printing, Title 44 Excerpts The United States Code - Printing, Title 44 Excerpts PDF icon The United ...

  8. INEL BWR severe accidnet ATWS study

    SciTech Connect

    Jouse, W.C.

    1983-01-01

    The subject of this study is a postulate Anticipated Transient Without Scram (ATWS) at unit one of the Browns Ferry nuclear plant, a boiling water reactor (BWR). The development work is being conducted at the Idaho National Engineering Laboratory (INEL) for the U.S. Nuclear Regulatory Commission (NRC). It has long been recognized that the dominant ATWS transient in BWRs is the main steamline isolation valve (MSIV) closure pressurization type of event. The analytic tool used in this study is RELAP5/MOD1.6. This version of RELAP5 has the capability to simulate BWR plants in that several special process models, such as a jet pump momentum mixer model, have been installed.

  9. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    Air Conditioning in U.S. Homes, by Housing Unit Type, 2009" " Million Housing Units, Final" ,,"Housing Unit Type" ,,"Single-Family Units",,"Apartments in Buildings With" ,"Total U.S.1 (millions)" ,," Detached"," Attached"," 2 to 4 Units","5 or More Units","Mobile Homes" "Air Conditioning" "Total Homes",113.6,71.8,6.7,9,19.1,6.9 "Air Conditioning Equipment"

  10. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    Water Heating in U.S. Homes, by Housing Unit Type, 2009" " Million Housing Units, Final" ,,"Housing Unit Type" ,,"Single-Family Units",,"Apartments in Buildings With" ,"Total U.S.1 (millions)" ,," Detached"," Attached"," 2 to 4 Units","5 or More Units","Mobile Homes" "Water Heating" "Total Homes",113.6,71.8,6.7,9,19.1,6.9 "Number of Storage Tank Water Heaters"

  11. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    Televisions in U.S. Homes, by Housing Unit Type, 2009" " Million Housing Units, Final" ,,"Housing Unit Type" ,,"Single-Family Units",,"Apartments in Buildings With" ,"Total U.S.1 (millions)" ,," Detached"," Attached"," 2 to 4 Units","5 or More Units","Mobile Homes" "Televisions" "Total Homes",113.6,71.8,6.7,9,19.1,6.9 "Televisions" "Number of

  12. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    Computers and Other Electronics in U.S. Homes, by Housing Unit Type, 2009" " Million Housing Units, Final" ,,"Housing Unit Type" ,,"Single-Family Units",,"Apartments in Buildings With" ,"Total U.S.1 (millions)" ,," Detached"," Attached"," 2 to 4 Units","5 or More Units","Mobile Homes" "Computers and Other Electronics" "Total Homes",113.6,71.8,6.7,9,19.1,6.9

  13. 1997 Housing Characteristics Tables Housing Unit Tables

    Energy Information Administration (EIA) (indexed site)

    Percent of U.S. Households; 45 pages, 121 kb) Contents Pages HC1-1b. Housing Unit Characteristics by Climate Zone, Percent of U.S. Households, 1997 4 HC1-2b. Housing Unit Characteristics by Year of Construction, Percent of U.S. Households, 1997 4 HC1-3b. Housing Unit Characteristics by Household Income, Percent of U.S. Households, 1997 4 HC1-4b. Housing Unit Characteristics by Type of Housing Unit, Percent of U.S. Households, 1997 3 HC1-5b. Housing Unit Characteristics by Type of Owner-Occupied

  14. Assessing Coal Unit Retirement Risk

    Energy Information Administration (EIA) (indexed site)

    Ventures Analysis 1901 N. Moore St. Arlington, VA 22209 (703) 276 8900 A S S E S S I N G C O A L U N I T R E T I R E M E N T R I S K Tom Hewson Principal June 14, 2016 Presentation for the US Energy Information Administration Workshop Coal Fleet Aging 1 COAL CAPACITY CHALLENGES E N E R G Y V E N T U R E S A N A L Y S I S , I N C .  Environmental Regulatory Risk-- Compliance often requires coal units to make large capital investment in additional retrofit control measures and/or increase their

  15. Compact monolithic capacitive discharge unit

    DOEpatents

    Roesler, Alexander W.; Vernon, George E.; Hoke, Darren A.; De Marquis, Virginia K.; Harris, Steven M.

    2007-06-26

    A compact monolithic capacitive discharge unit (CDU) is disclosed in which a thyristor switch and a flyback charging circuit are both sandwiched about a ceramic energy storage capacitor. The result is a compact rugged assembly which provides a low-inductance current discharge path. The flyback charging circuit preferably includes a low-temperature co-fired ceramic transformer. The CDU can further include one or more ceramic substrates for enclosing the thyristor switch and for holding various passive components used in the flyback charging circuit. A load such as a detonator can also be attached directly to the CDU.

  16. UNITED STATES DEPARTMENT OF ENERGY

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    DAVID N. "DAVE" LOPEZ Title: Senior Aviation Policy Officer Organization: Office of Aviation Management/MA-30 Address: Headquarters, United States Department of Energy 1000 Independence Avenue S.W. Washington, D.C. 20585 E-mail Address: David.Lopez@hq.doe.gov Phone Number: Office: (202) 586-6177, Mobile: (240) 449-0895 Fax Number: (202) 586-6008 Biographical Summary: Dave Lopez is a highly skilled manager and leader with over 34 years experience in government aviation operations and

  17. United States Department of Energy

    Energy Saver

    E-T Global Energy, LLC OE Docket No. EA-381 Order Authorizing Electricity Exports to Mexico Order No. EA-381 June 10, 2011 I. BACKGROUND E-T Global Energy, LLC Order No. EA-381 Exports of electricity from the United States to a foreign country are regulated by the Department of Energy (DOE) pursuant to sections 301(b) and 402(f) of the Department ofEnergy Organization Act (42 U.S.C. 7151(b), 7172(f)) and require authorization under section 202(e) ofthe Federal Power Act (FPA) (16 U.S.C.824a(e))

  18. United Ethanol LLC | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    United Ethanol LLC Place: Wisconsin Product: Developed a 43m gallon ethanol plant in Milton, Wisconsin. References: United Ethanol LLC1 This article is a stub. You can help...

  19. First United Ethanol LLC | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Ethanol LLC Jump to: navigation, search Name: First United Ethanol LLC Place: Camilla, Georgia Zip: 31730 Product: First United Ethanol LLC (FUEL) was formed to construct a 100 MGY...

  20. Efficiency United (Gas) - Commercial Efficiency Program | Department...

    Energy.gov [DOE] (indexed site)

    Furnace Tune-up: 15-100unit Infrared Heaters: 4MBH Hotel Guest Room Occupancy Sensor: 13unit Demand Control Ventilation: 0.05sq. ft. HVAC Occupancy Sensor: 0.02...

  1. Hills Creek Powerhouse Turbine and Unit Rehabilitation

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    Hills Creek Powerhouse Turbine and Unit Rehabilitation This project will replace the runners and windings for the two 17.5 MW units at the Hills Creek powerhouse. Hills Creek is a...

  2. Operable Generating Units in the United States by State and Energy...

    Energy Information Administration (EIA) (indexed site)

    Operable Generating Units in the United States by State and Energy Source, 2011" "Note: ...pageeia860.html." "Source: U.S. Energy Information Administration, Form EIA-860, ...

  3. Waste management units: Savannah River Site

    SciTech Connect

    Molen, G.

    1991-09-01

    This report indexes every waste management unit of the Savannah River Site. They are indexed by building number and name. The waste units are also tabulated by solid waste units receiving hazardous materials with a known release or no known release to the environment. It also contains information on the sites which has received no hazardous waste, and units which have received source, nuclear, or byproduct material only. (MB)

  4. Rooftop Unit Campaign | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Campaign Rooftop Unit Campaign Commercial Buildings Integration Project for the 2013 Building Technologies Office's Program Peer Review commlbldgs17_deru_040413.pdf (770.86 KB) More Documents & Publications Better Buildings Alliance - 2013 BTO Peer Review Rooftop Unit Suite: RTU Challenge, RTU Advanced Controls and RTU Smart Monitoring and Diagnostic System - 2013 BTO Peer Review Rooftop Unit Network Project - 2013 BTO Peer Review

  5. BANYAN. V. A SYSTEMATIC ALL-SKY SURVEY FOR NEW VERY LATE-TYPE LOW-MASS STARS AND BROWN DWARFS IN NEARBY YOUNG MOVING GROUPS

    SciTech Connect

    Gagn, Jonathan; Lafrenire, David; Doyon, Ren; Malo, Lison; Artigau, tienne

    2015-01-10

    We present the BANYAN All-Sky Survey (BASS) catalog, consisting of 228 new late-type (M4-L6) candidate members of nearby young moving groups (YMGs) with an expected false-positive rate of ?13%. This sample includes 79 new candidate young brown dwarfs and 22 planetary-mass objects. These candidates were identified through the first systematic all-sky survey for late-type low-mass stars and brown dwarfs in YMGs. We cross-matched the Two Micron All Sky Survey and AllWISE catalogs outside of the galactic plane to build a sample of 98,970 potential ?M5 dwarfs in the solar neighborhood and calculated their proper motions with typical precisions of 5-15 mas yr{sup 1}. We selected highly probable candidate members of several YMGs from this sample using the Bayesian Analysis for Nearby Young AssociatioNsII tool (BANYANII). We used the most probable statistical distances inferred from BANYANII to estimate the spectral type and mass of these candidate YMG members. We used this unique sample to show tentative signs of mass segregation in the AB Doradus moving group and the Tucana-Horologium and Columba associations. The BASS sample has already been successful in identifying several new young brown dwarfs in earlier publications, and will be of great interest in studying the initial mass function of YMGs and for the search of exoplanets by direct imaging; the input sample of potential close-by ?M5 dwarfs will be useful to study the kinematics of low-mass stars and brown dwarfs and search for new proper motion pairs.

  6. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    2 Structural and Geographic Characteristics of U.S. Homes, by Owner/Renter Status, 2009" " Million Housing Units, Final" ,,,,"Housing Unit Type" ,,,,"Single-Family Units",,,,"Apartments in Buildings With" ,,,,"Detached",,"Attached",,"2 to 4 Units",,"5 or More Units",,"Mobile Homes" ,"Total U.S.1 (millions)" "Structural and Geographic

  7. Waste management units - Savannah River Site. Volume 1, Waste management unit worksheets

    SciTech Connect

    Not Available

    1989-10-01

    This report is a compilation of worksheets from the waste management units of Savannah River Plant. Information is presented on the following: Solid Waste Management Units having received hazardous waste or hazardous constituents with a known release to the environment; Solid Waste Management Units having received hazardous waste or hazardous constituents with no known release to the environment; Solid Waste Management Units having received no hazardous waste or hazardous constituents; Waste Management Units having received source; and special nuclear, or byproduct material only.

  8. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    Fuels Used and End Uses in U.S. Homes, by Housing Unit Type, 2009" " Million Housing Units, Final" ,,"Housing Unit Type" ,,"Single-Family Units",,"Apartments in Buildings With" ,"Total U.S.1 (millions)" ,," Detached"," Attached"," 2 to 4 Units","5 or More Units","Mobile Homes" "Fuels Used and End Uses" "Total Homes",113.6,71.8,6.7,9,19.1,6.9 "Fuels Used for Any

  9. Dursley, United Kingdom: Energy Resources | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    United Kingdom. Registered Energy Companies in Dursley, United Kingdom Hermes Energy Services Retrieved from "http:en.openei.orgwindex.php?titleDursley,United...

  10. Nuclear Decommissioning Authority of the United Kingdom NDA ...

    OpenEI (Open Energy Information) [EERE & EIA]

    Decommissioning Authority of the United Kingdom NDA Jump to: navigation, search Name: Nuclear Decommissioning Authority of the United Kingdom (NDA) Place: Cumbria, England, United...

  11. United Arab Emirates-NREL Cooperation | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    United Arab Emirates-NREL Cooperation Jump to: navigation, search Logo: United Arab Emirates-NREL Cooperation Name United Arab Emirates-NREL Cooperation AgencyCompany...

  12. United Utilities Green Energy Ltd | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Green Energy Ltd Jump to: navigation, search Name: United Utilities Green Energy Ltd Place: England, United Kingdom Sector: Hydro, Renewable Energy Product: United Utilities Green...

  13. The United States Plutonium Balance, 1944-2009 | National Nuclear...

    National Nuclear Security Administration (NNSA)

    Pits The United States Plutonium Balance, 1944-2009 The United States Plutonium Balance, 1944-2009 The United States has released an inventory of its plutonium balances...

  14. Category:Territories of the United States | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Territories of the United States Jump to: navigation, search This category contains territories of the United States of America. Pages in category "Territories of the United...

  15. Characterization of novel sorghum brown midrib mutants from an EMS-mutagenized population

    SciTech Connect

    Sattler, Scott E.; Saballos, Ana; Xin, Zhanguo; Funnell-Harris, Deanna L.; Vermerris, Wilfred; Pedersen, Jeffrey F.

    2014-09-02

    Reducing lignin concentration in lignocellulosic biomass can increase forage digestibility for ruminant livestock and saccharification yields of biomass for bioenergy. In sorghum (Sorghum bicolor (L.) Moench) and several other C4 grasses, brown midrib (bmr) mutants have been shown to reduce lignin concentration. Putative bmr mutants isolated from an EMS-mutagenized population were characterized and classified based on their leaf midrib phenotype and allelism tests with the previously described sorghum bmr mutants bmr2, bmr6, and bmr12. These tests resulted in the identification of additional alleles of bmr2, bmr6,and bmr12, and, in addition, six bmr mutants were identified that were not allelic to these previously described loci. Further allelism testing among these six bmr mutants showed that they represented four novel bmr loci. Based on this study, the number of bmr loci uncovered in sorghum has doubled. The impact of these lines on agronomic traits and lignocellulosic composition was assessed in a 2-yr field study. Most of the identified bmr lines showed reduced lignin concentration of their biomass relative to wild-type (WT). Effects of the six new bmr mutants on enzymatic saccharification of lignocellulosic materials were determined, but the amount of glucose released from the stover was similar to WT in all cases. Like bmr2, bmr6, and bmr12, these mutants may affect monolignol biosynthesis and may be useful for bioenergy and forage improvement when stacked together or in combination with the three previously described bmr alleles.

  16. Effect of Solar Radiation on the Optical Properties and Molecular Composition of Laboratory Proxies of Atmospheric Brown Carbon

    SciTech Connect

    Lee, Hyun Ji; Aiona, Paige K.; Laskin, Alexander; Laskin, Julia; Nizkorodov, Sergey

    2014-09-02

    Sources, optical properties, and chemical composition of atmospheric brown carbon (BrC) aerosol are uncertain, making it challenging to estimate its contribution to radiative forcing. Furthermore, optical properties of BrC may change significantly during its atmospheric aging. We examined the effect of solar photolysis on the molecular composition, mass absorption coefficient, and fluorescence of secondary organic aerosol prepared by high-NOx photooxidation of naphthalene (NAP SOA). The aqueous solutions of NAP SOA was observed to photobleach with an effective half-time of ~15 hours (with sun in its zenith) for the loss of the near-UV (300 -400 nm) absorbance. The molecular composition of NAP SOA was significantly modified by photolysis, with the average SOA formula changing from C14.1H14.5O5.1N0.08 to C11.8H14.9O4.5N0.02 after 4 hours of irradiation. The average O/C ratio did not change significantly, however, suggesting that it is not a good metric for assessing the extent of photolysis-driven aging in NAP SOA (and in BrC in general). In contrast to NAP SOA, the photolysis of BrC material produced by aqueous reaction of limonene+O3 SOA (LIM/O3 SOA) with ammonium sulfate was much faster, but it did not result in a significant change in the molecular level composition. The characteristic absorbance of the aged LIM/O3 SOA in the 450-600 nm range decayed with an effective half-time of <0.5 hour. This result emphasizes the highly variable and dynamic nature of different types of atmospheric BrC.

  17. MOA-2010-BLG-073L: AN M-DWARF WITH A SUBSTELLAR COMPANION AT THE PLANET/BROWN DWARF BOUNDARY

    SciTech Connect

    Street, R. A.; Tsapras, Y.; Choi, J.-Y.; Han, C.; Furusawa, K.; Hundertmark, M.; Horne, K.; Dominik, M.; Browne, P.; Bajek, D.; Sumi, T.; Bond, I. A.; Wouters, D.; Zellem, R.; Udalski, A.; Snodgrass, C.; Kains, N.; Bramich, D. M.; Steele, I. A.; Collaboration: RoboNet Collaboration; MOA Collaboration; OGLE Collaboration; muFUN Collaboration; PLANET Collaboration; MiNDSTEp Collaboration; and others

    2013-01-20

    We present an analysis of the anomalous microlensing event, MOA-2010-BLG-073, announced by the Microlensing Observations in Astrophysics survey on 2010 March 18. This event was remarkable because the source was previously known to be photometrically variable. Analyzing the pre-event source light curve, we demonstrate that it is an irregular variable over timescales >200 days. Its dereddened color, (V - I) {sub S,0}, is 1.221 {+-} 0.051 mag, and from our lens model we derive a source radius of 14.7 {+-} 1.3 R {sub Sun }, suggesting that it is a red giant star. We initially explored a number of purely microlensing models for the event but found a residual gradient in the data taken prior to and after the event. This is likely to be due to the variability of the source rather than part of the lensing event, so we incorporated a slope parameter in our model in order to derive the true parameters of the lensing system. We find that the lensing system has a mass ratio of q = 0.0654 {+-} 0.0006. The Einstein crossing time of the event, t {sub E} = 44.3 {+-} 0.1 days, was sufficiently long that the light curve exhibited parallax effects. In addition, the source trajectory relative to the large caustic structure allowed the orbital motion of the lens system to be detected. Combining the parallax with the Einstein radius, we were able to derive the distance to the lens, D{sub L} = 2.8 {+-} 0.4 kpc, and the masses of the lensing objects. The primary of the lens is an M-dwarf with M {sub L,1} = 0.16 {+-} 0.03 M {sub Sun }, while the companion has M {sub L,2} = 11.0 {+-} 2.0 M {sub J}, putting it in the boundary zone between planets and brown dwarfs.

  18. Proteomic and Functional Analysis of the Cellulase System Expressed by Postia placenta during Brown Rot of Solid Wood

    SciTech Connect

    Ryu, Jae San; Shary, Semarjit; Houtman, Carl J.; Panisko, Ellen A.; Korripally, Premsagar; St John, Franz J.; Crooks, Casey; Siika-aho, Matti; Magnuson, Jon K.; Hammel, Ken

    2011-11-01

    Abstract Brown rot basidiomycetes have an important ecological role in lignocellulose recycling and are notable for their rapid degradation of wood polymers via oxidative and hydrolytic mechanisms. However, most of these fungi apparently lack processive (exo-acting) cellulases, such as cellobiohydrolases, which are generally required for efficient cellulolysis. The recent sequencing of the Postia placenta genome now permits a proteomic approach to this longstanding conundrum. We grew P. placenta on solid aspen wood, extracted proteins from the biodegrading substrate, and analyzed tryptic digests by shotgun liquid chromatography-tandem mass spectrometry. Comparison of the data with the predicted P. placenta proteome revealed the presence of 34 likely glycoside hydrolases, but only four of these-two in glycoside hydrolase family 5, one in family 10, and one in family 12-have sequences that suggested possible activity on cellulose. We expressed these enzymes heterologously and determined that they all exhibited endoglucanase activity on phosphoric acid-swollen cellulose. They also slowly hydrolyzed filter paper, a more crystalline substrate, but the soluble/insoluble reducing sugar ratios they produced classify them as nonprocessive. Computer simulations indicated that these enzymes produced soluble/insoluble ratios on reduced phosphoric acid-swollen cellulose that were higher than expected for random hydrolysis, which suggests that they could possess limited exo activity, but they are at best 10-fold less processive than cellobiohydrolases. It appears likely that P. placenta employs a combination of oxidative mechanisms and endo-acting cellulases to degrade cellulose efficiently in the absence of a significant processive component.

  19. Single Packaged Vertical Units | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Single Packaged Vertical Units Single Packaged Vertical Units The Department of Energy (DOE) develops standardized data templates for reporting the results of tests conducted in accordance with current DOE test procedures. Templates may be used by third-party laboratories under contract with DOE that conduct testing in support of ENERGY STAR® verification, DOE rulemakings, and enforcement of the federal energy conservation standards. Single Packaged Vertical Units -- v2.0 (103.53 KB) More

  20. United Cool Air | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Air United Cool Air While our process may start with a "basic model" it is seldom that we fabricate more than a few units that are identical. Therefore, the definition of "basic model" has a large impact on the implications associated with testing. United_Cool_Air.pdf (1 MB) More Documents & Publications Haier: Compromise Agreement (2011-SE-1428) GE Appliances: Order (2012-SE-1403) AeroSys: Noncompliance Determination (2010-SE-0302)

  1. Overview of Integrated Waste Treatment Unit

    Office of Environmental Management (EM)

    Integrated Waste Treatment Unit Overview Overview for the DOE High Level Waste Corporate Board March 5, 2009 safety performance cleanup closure M E Environmental ...

  2. United Electric Coop, Inc | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Number: (208)-679-2222 Website: www.unitedelectric.coop Twitter: @unitedelectricc Facebook: https:www.facebook.compagesUnited-Electric-Co-op298510305296 Outage Hotline:...

  3. United Bio Energy LLC | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    include consulting and plant management services, ingredients, procurement and marketing, ethanol marketing and hedging. References: United Bio Energy LLC1 This article is...

  4. United Power- Business Energy Efficiency Rebate Program

    Energy.gov [DOE]

    United Power, in conjunction with wholesale power supplier Tri-State Generation & Transmission (TSGT), offers rebates for the installation of a variety of commercial energy efficient equipment...

  5. National Nuclear Security Administration United States Department...

    National Nuclear Security Administration (NNSA)

    United States Department of Energy Washington, DC 20585 Prevent, Counter, and Respond-A ... Department of EnergyNational Nuclear Security Administration | March 2016 Prevent, ...

  6. United Nations Atomic Energy Commission stalls out

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    The United Nations Security Council should be the organization to which the envisioned ... The Acheson-Lilienthal Report proposed strict control of the raw materials needed for ...

  7. United States National Energy Technology Laboratory's (NETL)...

    OpenEI (Open Energy Information) [EERE & EIA]

    National Energy Technology Laboratory's (NETL) Smart Grid Implementation Strategy Reference Library Website Jump to: navigation, search Tool Summary LAUNCH TOOL Name: United States...

  8. Portable brine evaporator unit, process, and system

    DOEpatents

    Hart, Paul John; Miller, Bruce G.; Wincek, Ronald T.; Decker, Glenn E.; Johnson, David K.

    2009-04-07

    The present invention discloses a comprehensive, efficient, and cost effective portable evaporator unit, method, and system for the treatment of brine. The evaporator unit, method, and system require a pretreatment process that removes heavy metals, crude oil, and other contaminates in preparation for the evaporator unit. The pretreatment and the evaporator unit, method, and system process metals and brine at the site where they are generated (the well site). Thus, saving significant money to producers who can avoid present and future increases in transportation costs.

  9. Single Packaged Vertical Units | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    standards. File Single Packaged Vertical Units -- v2.0 More Documents & Publications Room Air Conditioners Commercial Refrigeration Equipment Commercial Refrigeration Equipment

  10. Oilwell Power Controller (OPC Unit). Technical report

    SciTech Connect

    Not Available

    1993-09-01

    Double M Electric, Inc. in Watford City, ND is finalizing the testing of its Oilwell Power Controller (OPC) Prototype Unit. This device can be used as a rod pump controller and it can also monitor, record and store power usage, temperature and pressure data. The unit also has the capability to measure the rod string weight, therefore it can be used as a dynamometer. A total of 10 OPC Units were assembled and installed on oilwells pumped with rod pumps in the Central and Western United States. Data from these wells was analyzed and forwarded to the participating oil companies.

  11. Ulubelu Unit 1 | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Information Name Ulubelu Unit 1 Facility Geothermal Power Plant Sector Geothermal energy Location Information Coordinates -5.2341767, 104.4606845 Loading map......

  12. Lahendong Unit 4 | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Information Name Lahendong Unit 4 Facility Geothermal Power Plant Sector Geothermal energy Location Information Coordinates 1.2764287, 124.8237803 Loading map......

  13. Lahendong Unit 2 | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Information Name Lahendong Unit 2 Facility Geothermal Power Plant Sector Geothermal energy Location Information Coordinates 1.2764287, 124.8237803 Loading map......

  14. Lahendong Unit 3 | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Information Name Lahendong Unit 3 Facility Geothermal Power Plant Sector Geothermal energy Location Information Coordinates 1.2764287, 124.8237803 Loading map......

  15. Ulubelu Unit 2 | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Information Name Ulubelu Unit 2 Facility Geothermal Power Plant Sector Geothermal energy Location Information Coordinates -5.2341767, 104.4606845 Loading map......

  16. Tribal Nations & the United States: An Introduction

    Office of Energy Efficiency and Renewable Energy (EERE)

    NCAI's Tribal Nations & the United States: An Introduction report provides a basic overview of the history and underlying principles of tribal governance.

  17. United Biofuels Inc | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Biofuels Inc Jump to: navigation, search Name: United Biofuels Inc Place: Plover, Wisconsin Zip: 54467 Sector: Biomass Product: Wisconsin-based manufacturer and distributor of...

  18. United States | OpenEI Community

    OpenEI (Open Energy Information) [EERE & EIA]

    load TMY3 United States Load data Image source: NREL Files: applicationzip icon System Advisor Model Tool for Downloading Load Data Graham7781's picture Submitted by...

  19. Total U.S. Housing Units...................................

    Energy Information Administration (EIA) (indexed site)

    ... Space Heating Usage Indicators Million U.S. Housing Units Detached Attached Energy Information Administration 2005 Residential Energy Consumption Survey: Preliminary Housing ...

  20. United States Atomic Energy Commission formed

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    Energy Commission failed to come to grips with the growing nuclear weapons problem, the United States worked to establish its own formal organization. The transition from...

  1. United Technologies Corp | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    United Technologies Corp Place: Hartford, Connecticut Zip: CT 06101 Sector: Hydro, Hydrogen Product: UTC is a global technology corporation with activities in aerospace,...

  2. United Oil Company | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Oil Company Jump to: navigation, search Name: United Oil Company Place: Pittsburgh, Pennsylvania Product: Vegetable-Oil producer Biodiesel producer based in Pittsburgh, PA...

  3. Problems of intraplate extensional tectonics, Western United...

    OpenEI (Open Energy Information) [EERE & EIA]

    tectonics, Western United States, with special emphasis on the Great Basin Author G.A. Davis Conference Basin and Range Symposium and Great Basin Field Conference; Denver,...

  4. Tribal Nations and the United States

    Office of Environmental Management (EM)

    ... Data source: http:factfinder2.census.gov. Retrieved on November 2014 from United Census Bureau - Facts for Features - American Indian and Alaska Native Heritage Month: ...

  5. DOE Tour of Zero: United Veterans Beacon House by United Way of Long Island

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    | Department of Energy United Veterans Beacon House by United Way of Long Island DOE Tour of Zero: United Veterans Beacon House by United Way of Long Island 1 of 16 United Way built this 1,890-square-foot home in Deer Park, Long Island, New York, to the performance criteria of the DOE Zero Energy Ready Home (ZERH) program. 2 of 16 The United Way home's average projected utility bills will be less than $60 a month thanks to a solar photovoltaic system and a high-performance building envelope.

  6. DOE Tour of Zero: United Veterans Beacon House by United Way of Long Island

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    | Department of Energy United Veterans Beacon House by United Way of Long Island DOE Tour of Zero: United Veterans Beacon House by United Way of Long Island Addthis 1 of 16 United Way built this 1,890-square-foot home in Deer Park, Long Island, New York, to the performance criteria of the DOE Zero Energy Ready Home (ZERH) program. 2 of 16 The United Way home's average projected utility bills will be less than $60 a month thanks to a solar photovoltaic system and a high-performance building

  7. The United Kingdom Nuclear Science Forum

    SciTech Connect

    MacMahon, Desmond; Judge, Steven; Forrest, Robin

    2005-05-24

    The United Kingdom Nuclear Science Forum effectively acts as the United Kingdom's Nuclear Data Committee. As such it is the interface between the UK nuclear data community and international nuclear data centres. This paper outlines the Forum's terms of reference and describes some of its recent activities.

  8. Enhanced hydrolysis and methane yield by applying microaeration pretreatment to the anaerobic co-digestion of brown water and food waste

    SciTech Connect

    Lim, Jun Wei; Wang, Jing-Yuan

    2013-04-15

    Highlights: ► Microaeration pretreatment was effective for brown water and food waste mixture. ► The added oxygen was consumed fully by facultative microorganisms. ► Enhanced solubilization, acidification and breakdown of SCFAs to acetate. ► Microaeration pretreatment improved methane yield by 10–21%. ► Nature of inoculum influenced the effects of microaeration. - Abstract: Microaeration has been used conventionally for the desulphurization of biogas, and recently it was shown to be an alternative pretreatment to enhance hydrolysis of the anaerobic digestion (AD) process. Previous studies on microaeration pretreatment were limited to the study of substrates with complex organic matter, while little has been reported on its effect on substrates with higher biodegradability such as brown water and food waste. Due to the lack of consistent microaeration intensities, previous studies were not comparable and thus inconclusive in proving the effectiveness of microaeration to the overall AD process. In this study, the role of microaeration pretreatment in the anaerobic co-digestion of brown water and food waste was evaluated in batch-tests. After a 4-day pretreatment with 37.5 mL-O{sub 2}/L{sub R}-d added to the liquid phase of the reactor, the methane production of substrates were monitored in anaerobic conditions over the next 40 days. The added oxygen was consumed fully by facultative microorganisms and a reducing environment for organic matter degradation was maintained. Other than higher COD solubilization, microaeration pretreatment led to greater VFA accumulation and the conversion of other short chain fatty acids to acetate. This could be due to enhanced activities of hydrolytic and acidogenic bacteria and the degradation of slowly biodegradable compounds under microaerobic conditions. This study also found that the nature of inoculum influenced the effects of microaeration as a 21% and 10% increase in methane yield was observed when pretreatment was

  9. Three new cool brown dwarfs discovered with the wide-field infrared survey explorer (WISE) and an improved spectrum of the Y0 dwarf wise J041022.71+150248.4

    SciTech Connect

    Cushing, Michael C.; Kirkpatrick, J. Davy; Gelino, Christopher R.; Mace, Gregory N.; Skrutskie, Michael F.; Gould, Andrew

    2014-05-01

    As part of a larger search of Wide-field Infrared Survey Explorer (WISE) data for cool brown dwarfs with effective temperatures less than 1000 K, we present the discovery of three new cool brown dwarfs with spectral types later than T7. Using low-resolution, near-infrared spectra obtained with the NASA Infrared Telescope Facility and the Hubble Space Telescope, we derive spectral types of T9.5 for WISE J094305.98+360723.5, T8 for WISE J200050.19+362950.1, and Y0: for WISE J220905.73+271143.9. The identification of WISE J220905.73+271143.9 as a Y dwarf brings the total number of spectroscopically confirmed Y dwarfs to 17. In addition, we present an improved spectrum (i.e., higher signal-to-noise ratio) of the Y0 dwarf WISE J041022.71+150248.4 that confirms the Cushing et al. classification of Y0. Spectrophotometric distance estimates place all three new brown dwarfs at distances less than 12 pc, with WISE J200050.19+362950.1 lying at a distance of only 3.9-8.0 pc. Finally, we note that brown dwarfs like WISE J200050.19+362950.1 that lie in or near the Galactic plane offer an exciting opportunity to directly measure the mass of a brown dwarf via astrometric microlensing.

  10. Effect of the ozonization of brown coal from the Kansk-Achinsk Basin on its pyrolysis in a mixture with polyethylene

    SciTech Connect

    V.I. Sharypov; N.G. Beregovtsova; S.V. Baryshnikov; B.N. Kuznetsov

    2008-06-15

    It was found that the treatment of brown coal from the Kansk-Achinsk Basin with an ozone-oxygen mixture at 25-100{sup o}C for 1-8 h was accompanied by the formation of oxygen-containing structural groups in the organic matter of coal, the thermal stability of these groups was comparatively low. The preliminary ozonization of coal resulted in an increase in the degree of conversion and the yield of liquid distillation products in the course of coprocessing of coal with polyethylene.

  11. SIMPJ21541055: A NEW LOW-GRAVITY L4? BROWN DWARF CANDIDATE MEMBER OF THE ARGUS ASSOCIATION

    SciTech Connect

    Gagn, Jonathan; Lafrenire, David; Doyon, Ren; Artigau, tienne; Malo, Lison; Robert, Jasmin; Nadeau, Daniel

    2014-09-01

    We present SIMPJ215434541055308, a new L4? brown dwarf identified in the SIMP survey that displays signs of low gravity in its near-infrared spectrum. Using BANYAN II, we show that it is a candidate member of the Argus association, albeit with a 21% probability that it is a contaminant from the field. Measurements of radial velocity and parallax will be needed to verify its membership. If it is a member of Argus (age 30-50Myr), then this object would have a planetary mass of 10 0.5M {sub Jup}.

  12. Pressure vessel sliding support unit and system using the sliding support unit

    DOEpatents

    Breach, Michael R.; Keck, David J.; Deaver, Gerald A.

    2013-01-15

    Provided is a sliding support and a system using the sliding support unit. The sliding support unit may include a fulcrum capture configured to attach to a support flange, a fulcrum support configured to attach to the fulcrum capture, and a baseplate block configured to support the fulcrum support. The system using the sliding support unit may include a pressure vessel, a pedestal bracket, and a plurality of sliding support units.

  13. Microsoft Word - UPDATE 5 - Units 1,2 + base load unit.doc

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    5 to: A Dispersion Modeling Analysis of Downwash from Mirant's Potomac River Power Plant Modeling Cycling Units 1, 2 plus One Baseload Unit ENSR Corporation January 6, 2006 Document Number 10350-002-420 (Update 5) January, 2006 1-1 1.0 INTRODUCTION This report describes dispersion modeling performed for simultaneous operation of one baseload unit and two cycling units at Mirant's Potomac River Generating Station (PRGS). This mode of operation is also referred to as Option A in Mirant Potomac

  14. Molecular Characterization of Brown Carbon (BrC) Chromophores in Secondary Organic Aerosol Generated From Photo-Oxidation of Toluene

    SciTech Connect

    Lin, Peng; Liu, Jiumeng; Shilling, John E.; Kathmann, Shawn M.; Laskin, Julia; Laskin, Alexander

    2015-09-28

    Atmospheric Brown carbon (BrC) is a significant contributor to light absorption and climate forcing. However, little is known about a fundamental relationship between the chemical composition of BrC and its optical properties. In this work, light-absorbing secondary organic aerosol (SOA) was generated in the PNNL chamber from toluene photo-oxidation in the presence of NOx (Tol-SOA). Molecular structures of BrC components were examined using nanospray desorption electrospray ionization (nano-DESI) and liquid chromatography (LC) combined with UV/Vis spectroscopy and electrospray ionization (ESI) high-resolution mass spectrometry (HRMS). The chemical composition of BrC chromophores and the light absorption properties of toluene SOA (Tol-SOA) depend strongly on the initial NOx concentration. Specifically, Tol-SOA generated under high-NOx conditions (defined here as initial NOx/toluene of 5/1) appears yellow and mass absorption coefficient of the bulk sample (MACbulk@365nm = 0.78 m2 g-1) is nearly 80 fold higher than that measured for the Tol-SOA sample generated under low-NOx conditions (NOx/toluene < 1/300). Fifteen compounds, most of which are nitrophenols, are identified as major BrC chromophores responsible for the enhanced light absorption of Tol-SOA material produced in the presence of NOx. The integrated absorbance of these fifteen chromophores accounts for 40-60% of the total light absorbance by Tol-SOA at wavelengths between 300 nm and 500 nm. The combination of tandem LC-UV/Vis-ESI/HRMS measurements provides an analytical platform for predictive understanding of light absorption properties by BrC and their relationship to the structure of individual chromophores. General trends in the UV/vis absorption by plausible isomers of the BrC chromophores were evaluated using theoretical chemistry calculations. The molecular-level understanding of BrC chemistry is helpful for better understanding the evolution and behavior of light absorbing aerosols in the atmosphere.

  15. Address conversion unit for multiprocessor system

    SciTech Connect

    Fava, T.F.; Lary, R.F.; Blackledge, R.

    1987-03-03

    An address conversion unit is described for use in one processor in a multi-processor data processing system including a common memory, the processors and common memory being interconnected by a common bus including means for transferring address signals defining a common address space. The processor includes private bus means including means for transferring signals including address signals defining a private address space. A processor unit means is connected to the private bus means and includes means for transmitting and receiving signals including address signals over the private bus means for engaging in data transfers thereover. The address conversion unit is connected to the private bus means and common bus means for receiving address signals over the private bus means from the processor unit means in the private address space. The unit comprises: A. pointer storage means for storing a pointer identifying a portion of the common bus memory space; B. pointer generation means connected to receive a common bus address and for generating a pointer in response thereto for storage in the pointer storage means; and C. common bus address generation means connected to the private bus and the pointer storage means for receiving an address from the processor unit means and for generating a common bus address in response thereto. The common bus address is used to initiate transfers between the processor unit means and the common memory over the common bus.

  16. brown-99.PDF

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    ... This will allow advanced echo characterization routines such as wavelet analysis (Jordan ... The authors wish to thank J. Jordan, C. Russell, and B. Templeman of NOAAETL for their ...

  17. Kate Brown | Bioenergy | NREL

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    Karina Edmonds About Us Karina Edmonds - Technology Transfer Coordinator Karina Edmonds Dr. Edmonds is a nationally recognized expert in the field of innovation, technology transfer and commercialization. She has over fifteen years of experience working with the private sector, universities and national laboratories across the country in the innovation space. Karina Edmonds was appointed Technology Transfer Coordinator for the U.S. Department of Energy (DOE) in April 2010 by Secretary of Energy

  18. Estimated United States Transportation Energy Use 2005

    SciTech Connect

    Smith, C A; Simon, A J; Belles, R D

    2011-11-09

    A flow chart depicting energy flow in the transportation sector of the United States economy in 2005 has been constructed from publicly available data and estimates of national energy use patterns. Approximately 31,000 trillion British Thermal Units (trBTUs) of energy were used throughout the United States in transportation activities. Vehicles used in these activities include automobiles, motorcycles, trucks, buses, airplanes, rail, and ships. The transportation sector is powered primarily by petroleum-derived fuels (gasoline, diesel and jet fuel). Biomass-derived fuels, electricity and natural gas-derived fuels are also used. The flow patterns represent a comprehensive systems view of energy used within the transportation sector.

  19. Microsoft Word - UPDATE 2 - Unit 1.doc

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    2 to: A Dispersion Modeling Analysis of Downwash from Mirant's Potomac River Power Plant Modeling Unit 1 Emissions at Maximum and Minimum Loads ENSR Corporation December 20, 2005 Document Number 10350-002-410 (Update 2) December, 2005 1-1 1.0 INTRODUCTION This report describes AERMOD modeling results performed for Unit 1 at Mirant's Potomac River Generating Station. The purpose of these runs was to demonstrate that operation of Unit 1 for 24 hours a day at loads from 35 MW to 88 MW with the use

  20. United Power- Energy Efficiency Rebate Program

    Energy.gov [DOE]

    United Power, together with Tri-State Generation and Transmission (TSGT), offers rebates for the installation of a variety of energy efficient equipment including heating and cooling systems, water...

  1. United States: Energy Resources | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    page. Country Profile Name United States Population 320,206,000 GDP Unavailable Energy Consumption 99.53 Quadrillion Btu 2-letter ISO code US 3-letter ISO code USA Numeric ISO...

  2. United Power- Renewable Energy Rebate Program

    Energy.gov [DOE]

    United Power is providing rebates to their customers for the purchase of photovoltaic (PV), wind, and solar water heating systems. These incentives are separate from the rebates provided by the...

  3. Hanford Site Waste Management Units Report

    SciTech Connect

    Shearer, Jeffrey P.

    2014-02-19

    The Hanford Site Waste Management Units Report (HSWMUR) has been created to meet the requirements of the Tri-Party Agreement (TPA) Action Plan, Section 3.5, which states: “The Hanford Site Waste Management Units Report shall be generated, in a format agreed upon by the Parties, as a calendar year report and issued annually by the DOE by the end of February of each year, and posted electronically for regulator and public access. This report shall reflect all changes made in waste management unit status during the previous year.” This February 2013 version of the HSWMUR contains a comprehensive inventory of the 3438 sites and 569 subsites in the Waste Information Data System (WIDS). The information for each site contains a description of each unit and the waste it contains, where applicable. The WIDS database provides additional information concerning the sites contained in this report and is maintained with daily changes to these sites.

  4. United States Entity Columbia River Treaty

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    BPA A-7 USACE CENWD-DE Ms. Sue Saarnio, Director Office of Canadian Affairs, WHA-CAN United States Department of State 2201 C Street Northwest Washington, D.C. 20520 Dear Ms....

  5. United States Government Department of Energy

    Office of Legacy Management (LM)

    os ' -sm;P 3irU - 001 f -325 F United States Government Department of Energy * memorandum DATE: AUG 16184 REPLY TO ATTN OP: NE-24 SUBJECT: Designation for Remedial Action at 454...

  6. United States Coast Guard | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    in Washington, District of Columbia. From Website: The U.S. Coast Guard is one of the five armed forces of the United States and the only military organization within the...

  7. "Table HC3.1 Housing Unit Characteristics by Owner-Occupied Housing Unit, 2005"

    Energy Information Administration (EIA) (indexed site)

    Housing Unit Characteristics by Owner-Occupied Housing Unit, 2005" " Million Housing Units" ,," Owner-Occupied Housing Units (millions)","Type of Owner-Occupied Housing Unit" ,"U.S. Housing Units (millions" ,,,"Single-Family Units",,"Apartments in Buildings With--" "Housing Unit Characteristics",,,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes"

  8. Indoor unit for electric heat pump

    DOEpatents

    Draper, R.; Lackey, R.S.; Fagan, T.J. Jr.; Veyo, S.E.; Humphrey, J.R.

    1984-05-22

    An indoor unit for an electric heat pump is provided in modular form including a refrigeration module, an air mover module, and a resistance heat package module, the refrigeration module including all of the indoor refrigerant circuit components including the compressor in a space adjacent the heat exchanger, the modules being adapted to be connected to air flow communication in several different ways as shown to accommodate placement of the unit in various orientations. 9 figs.

  9. Appalachian recapitalization: United Coal comes full circle

    SciTech Connect

    Fiscor, S.

    2006-05-15

    The article recounts the recent history of the United Coal Co. which exited from the coal business between 1992 and 1997 and has recently returned. More coal reserves have been added by its four companies Sapphire Coal, Carter Roag Coal, Pocahontas Coal and Wellmore, bringing the grand total to 222.6 Mtons. United Coal's developments and investment strategy are discussed. The company headquarters are in Bristol, Va., USA. 1 tab., 7 photos.

  10. Microsoft Word - UPDATE 4 - Unit 4.doc

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    4 to: A Dispersion Modeling Analysis of Downwash from Mirant's Potomac River Power Plant Modeling Unit 4 Emissions at Maximum and Minimum Loads ENSR Corporation December 23, 2005 Document Number 10350-002-410 (Update 4) December, 2005 1-1 1.0 INTRODUCTION This report describes dispersion modeling performed for Unit 4 at Mirant's Potomac River Generating Station. The modeling was performed according to the Protocol approved by the Virginia Department of Environmental Quality. The purpose of the

  11. Storage Resource Unit (SRU) Formula Coefficients

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    Formula Coefficients Storage Resource Unit (SRU) Formula Coefficients The coefficients in the Storage Resource Unit (SRU) formula were arrived at from the following considerations: - The formula should help influence user behavior towards efficient use of the storage resource. - The formula should reflect the relative costs of "doing business". From these considerations we adopted file counts, bytes stored and I/O transfers as the 3 minimum factors that needed to be included in the

  12. " Million U.S. Housing Units"

    Energy Information Administration (EIA) (indexed site)

    Housing Unit Characteristics by Type of Housing Unit, 2005" " Million U.S. Housing Units" ,,"Type of Housing Unit" ,"Housing Units (millions)","Single-Family Units",,"Apartments in Buildings With--" "Housing Unit Characteristics",,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total",111.1,72.1,7.6,7.8,16.7,6.9 "Census Region and

  13. Statistical evaluation of the effects of fall and winter flows on the spring condition of rainbow and brown trout in the green river downstream of Flaming Gorge Dam.

    SciTech Connect

    Magnusson, A. K.; LaGory, K. E.; Hayse, J. W.; Environmental Science Division

    2009-01-09

    Flaming Gorge Dam, a hydroelectric facility operated by the Bureau of Reclamation (Reclamation), is located on the Green River in Daggett County, northeastern Utah. In recent years, single peak releases each day or steady flows have been the operational pattern during the winter period. A double-peak pattern (two flow peaks each day) was implemented during the winter of 2006-2007 by Reclamation. Because there is no recent history of double-peaking at Flaming Gorge Dam, the potential effects of double-peaking operations on the body condition of trout in the dam's tailwater are not known. A study plan was developed that identified research activities to evaluate potential effects from double-peaking operations during winter months. Along with other tasks, the study plan identified the need to conduct a statistical analysis of existing data on trout condition and macroinvertebrate abundance to evaluate potential effects of hydropower operations. This report presents the results of this analysis. We analyzed historical data to (1) describe temporal patterns and relationships among flows, benthic macroinvertebrate abundance, and condition of brown trout (Salmo trutta) and rainbow trout (Oncorhynchus mykiss) in the tailwaters of Flaming Gorge Dam and (2) to evaluate the degree to which flow characteristics (i.e., flow volumes and flow variability) and benthic macroinvertebrate abundance affect the condition of trout in this area. This information, together with further analyses of size-stratified trout data, may also serve as baseline data to which the effects of potential future double-peaking flows can be compared. The condition (length, weight and/or relative weight) of rainbow trout (Oncorhynchus mykiss) at two sites in the Green River downstream of Flaming Gorge Dam (Tailrace and Little Hole) and weight of brown trout (Salmo trutta) at the Little Hole site has been decreasing since 1990 while the abundance of brown trout has been increasing at the two sites. At the

  14. United Arab Emirates and United States Sign MOU at Strategic Energy

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Dialogue | Department of Energy Arab Emirates and United States Sign MOU at Strategic Energy Dialogue United Arab Emirates and United States Sign MOU at Strategic Energy Dialogue October 1, 2014 - 1:50pm Addthis Secretary Moniz and UAE Minister of Energy Suhail Al Mazrouei signed a Memorandum of Understanding that reaffirms their commitment to a strong bilateral energy relationship, joint cooperation and exchange of ideas in the areas of energy and the energy-water nexus. Photo by

  15. Robust Unit Commitment Considering Uncertain Demand Response

    DOE PAGES [OSTI]

    Liu, Guodong; Tomsovic, Kevin

    2014-09-28

    Although price responsive demand response has been widely accepted as playing an important role in the reliable and economic operation of power system, the real response from demand side can be highly uncertain due to limited understanding of consumers' response to pricing signals. To model the behavior of consumers, the price elasticity of demand has been explored and utilized in both research and real practice. However, the price elasticity of demand is not precisely known and may vary greatly with operating conditions and types of customers. To accommodate the uncertainty of demand response, alternative unit commitment methods robust to themore » uncertainty of the demand response require investigation. In this paper, a robust unit commitment model to minimize the generalized social cost is proposed for the optimal unit commitment decision taking into account uncertainty of the price elasticity of demand. By optimizing the worst case under proper robust level, the unit commitment solution of the proposed model is robust against all possible realizations of the modeled uncertain demand response. Numerical simulations on the IEEE Reliability Test System show the e ectiveness of the method. Finally, compared to unit commitment with deterministic price elasticity of demand, the proposed robust model can reduce the average Locational Marginal Prices (LMPs) as well as the price volatility.« less

  16. Robust Unit Commitment Considering Uncertain Demand Response

    SciTech Connect

    Liu, Guodong; Tomsovic, Kevin

    2014-09-28

    Although price responsive demand response has been widely accepted as playing an important role in the reliable and economic operation of power system, the real response from demand side can be highly uncertain due to limited understanding of consumers' response to pricing signals. To model the behavior of consumers, the price elasticity of demand has been explored and utilized in both research and real practice. However, the price elasticity of demand is not precisely known and may vary greatly with operating conditions and types of customers. To accommodate the uncertainty of demand response, alternative unit commitment methods robust to the uncertainty of the demand response require investigation. In this paper, a robust unit commitment model to minimize the generalized social cost is proposed for the optimal unit commitment decision taking into account uncertainty of the price elasticity of demand. By optimizing the worst case under proper robust level, the unit commitment solution of the proposed model is robust against all possible realizations of the modeled uncertain demand response. Numerical simulations on the IEEE Reliability Test System show the e ectiveness of the method. Finally, compared to unit commitment with deterministic price elasticity of demand, the proposed robust model can reduce the average Locational Marginal Prices (LMPs) as well as the price volatility.

  17. Antenna unit and radio base station therewith

    DOEpatents

    Kuwahara, Mikio; Doi, Nobukazu; Suzuki, Toshiro; Ishida, Yuji; Inoue, Takashi; Niida, Sumaru

    2007-04-10

    Phase and amplitude deviations, which are generated, for example, by cables connecting an array antenna of a CDMA base station and the base station, are calibrated in the baseband. The base station comprises: an antenna apparatus 1; couplers 2; an RF unit 3 that converts a receive signal to a baseband signal, converts a transmit signal to a radio frequency, and performs power control; an A/D converter 4 for converting a receive signal to a digital signal; a receive beam form unit 6 that multiplies the receive signal by semi-fixed weight; a despreader 7 for this signal input; a time-space demodulator 8 for demodulating user data; a despreader 9 for probe signal; a space modulator 14 for user data; a spreader 13 for user signal; a channel combiner 12; a Tx calibrater 11 for controlling calibration of a signal; a D/A converter 10; a unit 16 for calculation of correlation matrix for generating a probe signal used for controlling an Rx calibration system and a TX calibration system; a spreader 17 for probe signal; a power control unit 18; a D/A converter 19; an RF unit 20 for probe signal; an A/D converter 21 for signal from the couplers 2; and a despreader 22.

  18. NIC atomic operation unit with caching and bandwidth mitigation

    DOEpatents

    Hemmert, Karl Scott; Underwood, Keith D.; Levenhagen, Michael J.

    2016-03-01

    A network interface controller atomic operation unit and a network interface control method comprising, in an atomic operation unit of a network interface controller, using a write-through cache and employing a rate-limiting functional unit.

  19. United Electric Coop Service Inc | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Twitter: @UnitedCoop Facebook: https:www.facebook.comUnitedCoopServices Outage Hotline: 817-556-4000 Outage Map: outage.united-cs.com References: EIA Form EIA-861...

  20. Inventory of Nonutility Electric Power Plants in the United States

    Reports and Publications

    2003-01-01

    Final issue of this report. Provides annual aggregate statistics on generating units operated by nonutilities in the United States and the District of Columbia. Provides a 5-year outlook for generating unit additions and changes.

  1. MODULAR CORE UNITS FOR A NEUTRONIC REACTOR

    DOEpatents

    Gage, J.F. Jr.; Sherer, D.B.

    1964-04-01

    A modular core unit for use in a nuclear reactor is described. Many identical core modules can be placed next to each other to make up a complete core. Such a module includes a cylinder of moderator material surrounding a fuel- containing re-entrant coolant channel. The re-entrant channel provides for the circulation of coolant such as liquid sodium from one end of the core unit, through the fuel region, and back out through the same end as it entered. Thermal insulation surrounds the moderator exterior wall inducing heat to travel inwardly to the coolant channel. Spaces between units may be used to accommodate control rods and support structure, which may be cooled by a secondary gas coolant, independently of the main coolant. (AEC)

  2. Closure Report for Corrective Action Unit 407: Roller Coaster RADSAFE Area, Tonopah Test Range, Nevada

    SciTech Connect

    T. M. Fitzmaurice

    2001-12-01

    This closure report (CR) provides documentation for the closure of the Roller Coaster RADSAFE Area (RCRSA) Corrective Action Unit (CAU) 407 identified in the Federal Facility Agreement and Consent Order (FFACO) (Nevada Division of Environmental Protection [NDEP] et al., 1996). CAU 407 is located at the Tonopah Test Range (TTR), Nevada. The TTR is approximately 225 kilometers (km) (140 miles [mi]) northwest of Las Vegas, Nevada (Figure 1). The RCRSA is located on the northeast comer of the intersection of Main Road and Browne's Lake Road, which is approximately 8 km (5 mi) south of Area 3 (Figure 1). The RCRSA was used during May and June of 1963 to decontaminate vehicles, equipment, and personnel from the Double Tracks and Clean Slate tests. Investigation of the RCRSA was conducted from June through November of 1998. A Corrective Action Decision Document (CADD) (U.S. Department of Energy, Nevada Operations Office [DOEN], 1999) was approved in October of 1999. The purpose of this CR is to: Document the closure activities as proposed in the Corrective Action Plan (CAP) (DOEM, 2000). Obtain a Notice of Completion from the NDEP. Recommend the movement of CAU 407 from Appendix III to Appendix IV of the FFACO. The following is the scope of the closure actions implemented for CAU 407: Removal and disposal of surface soils which were over three times background for the area. Soils identified for removal were disposed of at the Area 5 Radioactive Waste Management Site (RWMS) at the Nevada Test Site (NTS). Excavated areas were backfilled with clean borrow soil located near the site. A soil cover was constructed over the waste disposal pit area, where subsurface constituents of concern remain. The site was fenced and posted as an ''Underground Radioactive Material'' area.

  3. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    4 Appliances in U.S. Homes, by Number of Household Members, 2009" " Million Housing Units, Final" ,,"Number of Household Members" ,"Total U.S.1 (millions)" ,,,,,,"5 or More Members" "Appliances",,"1 Member","2 Members","3 Members","4 Members" "Total Homes",113.6,31.3,35.8,18.1,15.7,12.7 "Cooking Appliances" "Stoves (Units With Both" "an Oven and a Cooktop)"

  4. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    6 Appliances in U.S. Homes, by Climate Region, 2009" " Million Housing Units, Final" ,,"Climate Region2" ,"Total U.S.1 (millions)" ,,"Very Cold/","Mixed- Humid","Mixed-Dry/" "Appliances",,"Cold",,"Hot-Dry","Hot-Humid","Marine" "Total Homes",113.6,38.8,35.4,14.1,19.1,6.3 "Cooking Appliances" "Stoves (Units With Both" "an Oven and a Cooktop)"

  5. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    7 Appliances in U.S. Homes, by Census Region, 2009" " Million Housing Units, Final" ,"Total U.S.1 (millions)","Census Region" "Appliances",,"Northeast","Midwest","South","West" "Total Homes",113.6,20.8,25.9,42.1,24.8 "Cooking Appliances" "Stoves (Units With Both" "an Oven and a Cooktop)" "Use a Stove",102.3,19.2,23.9,38.2,20.9

  6. Unit cell of strained GeSi

    SciTech Connect

    Woicik, J.C.; Bouldin, C.E.; Miyano, K.E.; King, C.A.

    1997-06-01

    The local structure within the unit cell of strained-GeSi layers grown on Si(001) has been examined by polarization-dependent extended x-ray-absorption fine structure. First-neighbor bond lengths are found to deviate only slightly from their unstrained values; however, the distortion of the cubic-unit cell by strain leads to measurable polarization-dependent changes in first-shell coordination and second-shell distances. A unifying picture of bond lengths and elasticity in strained-layer semiconductors is presented. {copyright} {ital 1997} {ital The American Physical Society}

  7. Indoor unit for electric heat pump

    DOEpatents

    Draper, Robert; Lackey, Robert S.; Fagan, Jr., Thomas J.; Veyo, Stephen E.; Humphrey, Joseph R.

    1984-01-01

    An indoor unit for an electric heat pump is provided in modular form including a refrigeration module 10, an air mover module 12, and a resistance heat package module 14, the refrigeration module including all of the indoor refrigerant circuit components including the compressor 36 in a space adjacent the heat exchanger 28, the modules being adapted to be connected to air flow communication in several different ways as shown in FIGS. 4-7 to accommodate placement of the unit in various orientations.

  8. Influence of additives on the increase of the heating value of Bayah’s coal with upgrading brown coal (UBC) method

    SciTech Connect

    Heriyanto, Heri; Widya Ernayati, K.; Umam, Chairul; Margareta, Nita

    2015-12-29

    UBC (upgrading brown coal) is a method of improving the quality of coal by using oil as an additive. Through processing in the oil media, not just the calories that increase, but there is also water repellent properties and a decrease in the tendency of spontaneous combustion of coal products produced. The results showed a decrease in the water levels of natural coal bayah reached 69%, increase in calorific value reached 21.2%. Increased caloric value and reduced water content caused by the water molecules on replacing seal the pores of coal by oil and atoms C on the oil that is bound to increase the percentage of coal carbon. As a result of this experiment is, the produced coal has better calorific value, the increasing of this new calorific value up to 23.8% with the additive waste lubricant, and the moisture content reduced up to 69.45%.

  9. Xiamien King Long United Automotive Industry Suzhou | Open Energy...

    OpenEI (Open Energy Information) [EERE & EIA]

    Xiamien King Long United Automotive Industry Suzhou Jump to: navigation, search Name: Xiamien King Long United Automotive Industry (Suzhou) Place: Suzhou, Fujian Province, China...

  10. Demonstrations of Integrated Advanced Rooftop Unit Controls and...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Demonstrations of Integrated Advanced Rooftop Unit Controls and Automated Fault Detection and Diagnostics - 2014 BTO Peer Review Demonstrations of Integrated Advanced Rooftop Unit...

  11. Shared Space vs. In-Unit Upgrades in Multifamily Buildings |...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Shared Space vs. In-Unit Upgrades in Multifamily Buildings Shared Space vs. In-Unit Upgrades in Multifamily Buildings Better Buildings Neighborhood Program Multifamily Peer...

  12. Statement: Committee on Environment and Public Works United States...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Statement: Committee on Environment and Public Works United States Senate Statement: Committee on Environment and Public Works United States Senate Senate Testimony Committee on...

  13. " Million U.S. Housing Units"

    Energy Information Administration (EIA) (indexed site)

    5 Space Heating Usage Indicators by Type of Housing Unit, 2005" " Million U.S. Housing Units" ,,"Type of Housing Unit" ,"Housing Units (millions)","Single-Family Units",,"Apartments in Buildings With--" "Space Heating Usage Indicators",,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total U.S. Housing Units",111.1,72.1,7.6,7.8,16.7,6.9 "Do Not

  14. " Million U.S. Housing Units"

    Energy Information Administration (EIA) (indexed site)

    3 Lighting Usage Indicators by Type of Housing Unit, 2005" " Million U.S. Housing Units" ,,"Type of Housing Unit" ,"Housing Units (millions)","Single-Family Units",,"Apartments in Buildings With--" "Lighting Usage Indicators",,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total U.S. Housing Units",111.1,72.1,7.6,7.8,16.7,6.9 "Indoor Lights

  15. United Wisconsin Grain Producers UWGP | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Name: United Wisconsin Grain Producers (UWGP) Place: Friesland, Wisconsin Product: Bioethanol producer using corn as feedstock References: United Wisconsin Grain Producers...

  16. Control and Diagnostics for Rooftop Units - 2014 BTO Peer Review...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Control and Diagnostics for Rooftop Units - 2014 BTO Peer Review Control and Diagnostics for Rooftop Units - 2014 BTO Peer Review Presenter: Jim Braun, Purdue University (The ...

  17. Executive Order -- Preparing the United States for the Impacts...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Executive Order -- Preparing the United States for the Impacts of Climate Change Executive Order -- Preparing the United States for the Impacts of Climate Change ...

  18. Savannah River Site - C-Area Groundwater Operable Unit | Department...

    Office of Environmental Management (EM)

    C-Area Groundwater Operable Unit Savannah River Site - C-Area Groundwater Operable Unit ... InstallationName, State: Savannah River Site, SC Responsible DOE Office: Savannah River ...

  19. Savannah River Site - R-Area Groundwater Operable Unit | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    R-Area Groundwater Operable Unit Savannah River Site - R-Area Groundwater Operable Unit ... InstallationName, State: Savannah River Site, SC Responsible DOE Office: Savannah River ...

  20. Biodiesel Quality in the United States | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Quality in the United States Biodiesel Quality in the United States Poster presentaltion ... More Documents & Publications Effect of Biodiesel Blends on NOx Emissions Diesel Injection ...

  1. Energy Units - Energy Explained, Your Guide To Understanding...

    Energy Information Administration (EIA) (indexed site)

    Calculators Energy Explained - Home What Is Energy? Forms of Energy Sources of Energy Laws of Energy Units and Calculators Energy Conversion Calculators British Thermal Units (Btu) ...

  2. Lianyungang Zhongneng United Wind Power Co Ltd | Open Energy...

    OpenEI (Open Energy Information) [EERE & EIA]

    Zhongneng United Wind Power Co Ltd Jump to: navigation, search Name: Lianyungang Zhongneng United Wind Power Co Ltd Place: Lianyungang, Jiangsu Province, China Sector: Wind energy...

  3. Produced water volumes and management practices in the United...

    Office of Scientific and Technical Information (OSTI)

    Produced water volumes and management practices in the United States. Citation Details In-Document Search Title: Produced water volumes and management practices in the United ...

  4. Offshore Wind Jobs and Economic Development Impacts in the United...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Offshore Wind Jobs and Economic Development Impacts in the United States: Four Regional Scenarios Offshore wind has tremendous potential in the United States as a clean, renewable ...

  5. Beijing Transform United New Energy Investment Co Ltd | Open...

    OpenEI (Open Energy Information) [EERE & EIA]

    United New Energy Investment Co Ltd Jump to: navigation, search Name: Beijing Transform United New Energy Investment Co.,Ltd. Place: Beijing, China Zip: 100005 Product: The clean...

  6. Beijing Zhongneng United Renewable Energy Investment Co Ltd ...

    OpenEI (Open Energy Information) [EERE & EIA]

    Zhongneng United Renewable Energy Investment Co Ltd Jump to: navigation, search Name: Beijing Zhongneng United Renewable Energy Investment Co Ltd Place: Beijing Municipality, China...

  7. Mapping and Assessment of the United States Ocean Wave Energy...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Mapping and Assessment of the United States Ocean Wave Energy Resource Mapping and Assessment of the United States Ocean Wave Energy Resource This report describes the analysis and ...

  8. Electronic unit integrated into a flexible polymer body (Patent...

    Office of Scientific and Technical Information (OSTI)

    Electronic unit integrated into a flexible polymer body Citation Details In-Document Search Title: Electronic unit integrated into a flexible polymer body A peel and stick ...

  9. Solar Thin Films Inc formerly American United Global Inc | Open...

    OpenEI (Open Energy Information) [EERE & EIA]

    Films Inc formerly American United Global Inc Jump to: navigation, search Name: Solar Thin Films Inc (formerly American United Global Inc) Place: New York, New York Zip: 10038...

  10. EWIS European wind integration study (Smart Grid Project) (United...

    OpenEI (Open Energy Information) [EERE & EIA]

    United Kingdom) Jump to: navigation, search Project Name EWIS European wind integration study Country United Kingdom Coordinates 55.378052, -3.435973 Loading map......

  11. BeyWatch (Smart Grid Project) (United Kingdom) | Open Energy...

    OpenEI (Open Energy Information) [EERE & EIA]

    United Kingdom) Jump to: navigation, search Project Name BeyWatch Country United Kingdom Coordinates 55.378052, -3.435973 Loading map... "minzoom":false,"mappingservice":"goog...

  12. Abu Dhabi, United Arab Emirates: Energy Resources | Open Energy...

    OpenEI (Open Energy Information) [EERE & EIA]

    Dhabi, United Arab Emirates: Energy Resources Jump to: navigation, search Name Abu Dhabi, United Arab Emirates Equivalent URI DBpedia GeoNames ID 292968 Coordinates 24.46667,...

  13. Dubai, United Arab Emirates: Energy Resources | Open Energy Informatio...

    OpenEI (Open Energy Information) [EERE & EIA]

    Dubai, United Arab Emirates: Energy Resources Jump to: navigation, search Name Dubai, United Arab Emirates Equivalent URI DBpedia GeoNames ID 292223 Coordinates 25.252222,...

  14. UNITED STATES DEPARTMENT OF ENERGY OFFICE OF CIVILIAN RADIOACTIVE...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    UNITED STATES DEPARTMENT OF ENERGY OFFICE OF CIVILIAN RADIOACTIVE WASTE MANAGEMENT Annual Financial Report Years Ended September 30, 2009 and 2008 UNITED STATES DEPARTMENT OF ...

  15. Data Collection and Comparison with Forecasted Unit Sales of...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Data Collection and Comparison with Forecasted Unit Sales of Five Lamp Types Data Collection and Comparison with Forecasted Unit Sales of Five Lamp Types PDF icon Data Collection ...

  16. United States Marks 20 Years without Underground Nuclear Explosive...

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    United States Marks 20 Years without Underground Nuclear Explosive Testing September 21, 2012 WASHINGTON, DC -- Twenty years ago, on September 23, 1992, the United States conducted ...

  17. United Kingdom Department of Energy and Climate Change (DECC...

    OpenEI (Open Energy Information) [EERE & EIA]

    Department of Energy and Climate Change (DECC) Jump to: navigation, search Logo: United Kingdom Department for Energy and Climate Change (DECC) Name: United Kingdom Department for...

  18. NUON Renewable Energy Business Unit | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    NUON Renewable Energy Business Unit Jump to: navigation, search Name: NUON Renewable Energy Business Unit Place: Arnhem, Netherlands Zip: 6800 EZ Sector: Renewable Energy Product:...

  19. United States, Australia, and Iceland to Promote Geothermal Energy...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    United States, Australia, and Iceland to Promote Geothermal Energy United States, Australia, and Iceland to Promote Geothermal Energy August 28, 2008 - 12:43pm Addthis Photo of ...

  20. Exhibit A: ENSR Modeling in Support of Individual Unit Operation...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    and Proposed Mirant Compliance Plan Exhibit D: Mirant Potomac River Schedule of Unit Operations: January - March 2006 Exhibit D: Mirant Potomac River Schedule of Unit ...

  1. MHK Technologies/OCGen turbine generator unit TGU | Open Energy...

    OpenEI (Open Energy Information) [EERE & EIA]

    OCGen turbine generator unit TGU < MHK Technologies Jump to: navigation, search << Return to the MHK database homepage OCGen turbine generator unit TGU.jpg Technology Profile...

  2. 3.0 UNIT IDENTIFICATION, CLASSIFICATION, AND PRIORITIZATION

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    unit at the Hanford Site. In addition, it describes how waste management units are classified, prioritized, and grouped for common investigation and response or corrective action. ...

  3. NREL-United States/Brazil Bioenergy Technical Workshop | Open...

    OpenEI (Open Energy Information) [EERE & EIA]

    United StatesBrazil Bioenergy Technical Workshop Jump to: navigation, search Tool Summary LAUNCH TOOL Name: NREL-United StatesBrazil Bioenergy Technical Workshop AgencyCompany...

  4. Electric Wholesale Market Regimes in the United States: Implications...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Wholesale Market Regimes in the United States: Implications for Investment Electric Wholesale Market Regimes in the United States: Implications for Investment PowerPoint ...

  5. Guanquan Shandong Photoelectric Technology aka United LED Corporation...

    OpenEI (Open Energy Information) [EERE & EIA]

    Guanquan Shandong Photoelectric Technology aka United LED Corporation Jump to: navigation, search Name: Guanquan (Shandong) Photoelectric Technology (aka United LED Corporation)...

  6. United Cooperative Services- Residential Energy Efficiency Rebate Program

    Energy.gov [DOE]

    United Cooperative Services offers a one-time rebate program for new home construction and retrofit upgrades. The following equipment are eligible under United's Rebate Program:

  7. Overview and Progress of United States Advanced Battery Research...

    Energy.gov [DOE] (indexed site)

    Vehicle Technologies Office Merit Review 2016: Overview and Progress of United States Advanced Battery Consortium (USABC) Activity United States Advanced Battery Consortium ...

  8. United States Coast Guard Bridge Administration Manual | Open...

    OpenEI (Open Energy Information) [EERE & EIA]

    United States Coast Guard Bridge Administration Manual Jump to: navigation, search OpenEI Reference LibraryAdd to library PermittingRegulatory Guidance - GuideHandbook: United...

  9. United Nations Energy Knowledge Network (UN-Energy) | Open Energy...

    OpenEI (Open Energy Information) [EERE & EIA]

    Energy Knowledge Network (UN-Energy) Jump to: navigation, search Logo: United Nations Energy Knowledge Network (UN-Energy) Name: United Nations Energy Knowledge Network (UN-Energy)...

  10. Price Liquefied Freeport, TX Natural Gas Exports Price to United...

    Annual Energy Outlook

    United Kingdom (Dollars per Thousand Cubic Feet) Price Liquefied Freeport, TX Natural Gas Exports Price to United Kingdom (Dollars per Thousand Cubic Feet) Decade Year-0 Year-1...

  11. United Kingdom Low Carbon Transition Plan | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Low Carbon Transition Plan Jump to: navigation, search Tool Summary LAUNCH TOOL Name: United Kingdom Low Carbon Transition Plan AgencyCompany Organization: United Kingdom...

  12. Before the Committee on Energy and Natural Resources United States...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Energy and Natural Resources United States Senate Before the Committee on Energy and Natural Resources United States Senate Statement Before the Committee on Energy and Natural ...

  13. DOE Awards Contract for WIPP Mobile Loading Unit Services | Department...

    Office of Environmental Management (EM)

    WIPP Mobile Loading Unit Services DOE Awards Contract for WIPP Mobile Loading Unit ... awarded a competitive small business contract to Celeritex, LLC, (a Joint Venture ...

  14. Solar Energy in the United States | Department of Energy

    Office of Environmental Management (EM)

    Solar Energy in the United States Solar Energy in the United States President's Climate Action Plan President's Climate Action Plan In June 2013, President Obama put forward a ...

  15. Canada-United States Regulatory Cooperation Council Webinar:...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Canada-United States Regulatory Cooperation Council Webinar: Proposed Approach for Energy Efficiency Standards Canada-United States Regulatory Cooperation Council Webinar: Proposed ...

  16. CANADA-UNITED STATES REGULATORY COOPERATION COUNCIL Webinar:...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    CANADA-UNITED STATES REGULATORY COOPERATION COUNCIL Webinar: Work Plan Development - 201617; April 12, 2016 CANADA-UNITED STATES REGULATORY COOPERATION COUNCIL Webinar: Work Plan ...

  17. STATEMENT OF BRIGADIER GENERAL JOHN KEM COMMANDER UNITED STATES...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    BRIGADIER GENERAL JOHN KEM COMMANDER UNITED STATES ARMY CORPS OF ENGINEERS NORTHWESTERN DIVISION MEMBER, UNITED STATES ENTITY FOR THE COLUMBIA RIVER TREATY AND STEPHEN OLIVER VICE...

  18. United Nations Population Information Network | Open Energy Informatio...

    OpenEI (Open Energy Information) [EERE & EIA]

    Focus Area: People and Policy Resource Type: Dataset Website: www.un.orgpopin Cost: Free United Nations Population Information Network Screenshot References: United Nations...

  19. Microwave Regenerated DPF for Auxiliary Power Units and Diesel...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Microwave Regenerated DPF for Auxiliary Power Units and Diesel Hybrid Vehicles Microwave Regenerated DPF for Auxiliary Power Units and Diesel Hybrid Vehicles Microwave regeneration ...

  20. Shared Space vs. In-Unit Upgrades in Multifamily Buildings |...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Shared Space vs. In-Unit Upgrades in Multifamily Buildings Shared Space vs. In-Unit Upgrades in Multifamily Buildings Better Buildings Neighborhood Program Multifamily Peer ...

  1. United States Department of Transportation | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    United States Department of Transportation Name: United States Department of Transportation Address: 1200 New Jersey Ave, SE Place: Washington, District of Columbia Zip: 20590 Year...

  2. United States Department of Defense | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Defense Jump to: navigation, search Logo: United States Department of Defense Name: United States Department of Defense Address: 1000 Defense Pentagon Place: Washington, District...

  3. United States Department of Interior | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    Interior Jump to: navigation, search Logo: United States Department of Interior Name: United States Department of Interior Address: 1849 C Street NW Place: Washington, District of...

  4. United States Department of Energy | Open Energy Information

    OpenEI (Open Energy Information) [EERE & EIA]

    United States Department of Energy (Redirected from US DOE) Redirect page Jump to: navigation, search REDIRECT DOE Retrieved from "http:en.openei.orgwindex.php?titleUnitedSt...

  5. Largest Producer of Steel Products in the United States Achieves...

    Office of Environmental Management (EM)

    Largest Producer of Steel Products in the United States Achieves Significant Energy Savings at its Minntac Plant Largest Producer of Steel Products in the United States Achieves ...

  6. The Next Generation Air Particle Detectors for the United States...

    Office of Scientific and Technical Information (OSTI)

    The Next Generation Air Particle Detectors for the United States Navy Citation Details In-Document Search Title: The Next Generation Air Particle Detectors for the United States ...

  7. Demonstrations of Integrated Advanced Rooftop Unit Controls and...

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    of energy savings achievable by retrofitting existing packaged rooftop air conditioner units (RTUs) with advanced control strategies not ordinarily used for packaged units. ...

  8. CHARACTERIZATION OF THE NEARBY L/T BINARY BROWN DWARF WISE J104915.57-531906.1 AT 2 pc FROM THE SUN

    SciTech Connect

    Kniazev, A. Y.; Vaisanen, P.; Potter, S. B.; Crawford, S.; Gulbis, A. A. S.; Muzic, K.; Mehner, A.; Boffin, H. M. J.; Melo, C.; Ivanov, V. D.; Girard, J.; Mawet, D.; Schmidtobreick, L.; Kurtev, R.; Borissova, J.; Huelamo, N.; Minniti, D.; Ishibashi, K.; Beletsky, Y.; Buckley, D. A. H.; and others

    2013-06-20

    WISE J104915.57-531906.1 is a L/T brown dwarf binary located 2 pc from the Sun. The pair contains the closest known brown dwarfs and is the third closest known system, stellar or sub-stellar. We report comprehensive follow-up observations of this newly uncovered system. We have determined the spectral types of both components (L8 {+-} 1, for the primary, agreeing with the discovery paper; T1.5 {+-} 2 for the secondary, which was lacking spectroscopic type determination in the discovery paper) and, for the first time, their radial velocities (V{sub rad} {approx} 23.1, 19.5 km s{sup -1}) using optical spectra obtained at the Southern African Large Telescope and other facilities located at the South African Astronomical Observatory (SAAO). The relative radial velocity of the two components is smaller than the range of orbital velocities for theoretically predicted masses, implying that they form a gravitationally bound system. We report resolved near-infrared JHK{sub S} photometry from the Infrared Survey Facility telescope at the SAAO which yields colors consistent with the spectroscopically derived spectral types. The available kinematic and photometric information excludes the possibility that the object belongs to any of the known nearby young moving groups or associations. Simultaneous optical polarimetry observations taken at the SAAO 1.9 m give a non-detection with an upper limit of 0.07%. For the given spectral types and absolute magnitudes, 1 Gyr theoretical models predict masses of 0.04-0.05 M{sub Sun} for the primary, and 0.03-0.05 M{sub Sun} for the secondary.

  9. Tamoxifen affects glucose and lipid metabolism parameters, causes browning of subcutaneous adipose tissue and transient body composition changes in C57BL/6NTac mice

    SciTech Connect

    Hesselbarth, Nico; Pettinelli, Chiara; Gericke, Martin; Berger, Claudia; Kunath, Anne; Stumvoll, Michael; Blüher, Matthias; Klöting, Nora

    2015-08-28

    Tamoxifen is a selective estrogen receptor (ER) modulator which is widely used to generate inducible conditional transgenic mouse models. Activation of ER signaling plays an important role in the regulation of adipose tissue (AT) metabolism. We therefore tested the hypothesis that tamoxifen administration causes changes in AT biology in vivo. 12 weeks old male C57BL/6NTac mice were treated with either tamoxifen (n = 18) or vehicle (n = 18) for 5 consecutive days. Tamoxifen treatment effects on body composition, energy homeostasis, parameters of AT biology, glucose and lipid metabolism were investigated up to an age of 18 weeks. We found that tamoxifen treatment causes: I) significantly increased HbA{sub 1c}, triglyceride and free fatty acid serum concentrations (p < 0.01), II) browning of subcutaneous AT and increased UCP-1 expression, III) increased AT proliferation marker Ki67 mRNA expression, IV) changes in adipocyte size distribution, and V) transient body composition changes. Tamoxifen may induce changes in body composition, whole body glucose and lipid metabolism and has significant effects on AT biology, which need to be considered when using Tamoxifen as a tool to induce conditional transgenic mouse models. Our data further suggest that tamoxifen-treated wildtype mice should be characterized in parallel to experimental transgenic models to control for tamoxifen administration effects. - Highlights: • Tamoxifen treatment causes significantly increased HbA{sub 1c}, triglyceride and free fatty acid serum concentrations. • Tamoxifen induces browning of subcutaneous AT and increased UCP-1 expression. • Tamoxifen changes adipocyte size distribution, and transient body composition.

  10. THE BROWN DWARF KINEMATICS PROJECT (BDKP). IV. RADIAL VELOCITIES OF 85 LATE-M AND L DWARFS WITH MagE

    SciTech Connect

    Burgasser, Adam J.; Logsdon, Sarah E.; Gagné, Jonathan; Bochanski, John J.; Faherty, Jaqueline K.; West, Andrew A.; Mamajek, Eric E.; Schmidt, Sarah J.; Cruz, Kelle L.

    2015-09-15

    Radial velocity measurements are presented for 85 late M- and L-type very low-mass stars and brown dwarfs obtained with the Magellan Echellette spectrograph. Targets primarily have distances within 20 pc of the Sun, with more distant sources selected for their unusual spectral energy distributions. We achieved precisions of 2–3 km s{sup −1}, and combined these with astrometric and spectrophotometric data to calculate UVW velocities. Most are members of the thin disk of the Galaxy, and velocity dispersions indicate a mean age of 5.2 ± 0.2 Gyr for sources within 20 pc. We find signficantly different kinematic ages between late-M dwarfs (4.0 ± 0.2 Gyr) and L dwarfs (6.5 ± 0.4 Gyr) in our sample that are contrary to predictions from prior simulations. This difference appears to be driven by a dispersed population of unusually blue L dwarfs which may be more prevalent in our local volume-limited sample than in deeper magnitude-limited surveys. The L dwarfs exhibit an asymmetric U velocity distribution with a net inward flow, similar to gradients recently detected in local stellar samples. Simulations incorporating brown dwarf evolution and Galactic orbital dynamics are unable to reproduce the velocity asymmetry, suggesting non-axisymmetric perturbations or two distinct L dwarf populations. We also find the L dwarfs to have a kinematic age-activity correlation similar to more massive stars. We identify several sources with low surface gravities, and two new substellar candidate members of nearby young moving groups: the astrometric binary DENIS J08230313–4912012AB, a low-probability member of the β Pictoris Moving Group; and 2MASS J15104786–2818174, a moderate-probability member of the 30–50 Myr Argus Association.

  11. Graphics processing unit-assisted lossless decompression

    DOEpatents

    Loughry, Thomas A.

    2016-04-12

    Systems and methods for decompressing compressed data that has been compressed by way of a lossless compression algorithm are described herein. In a general embodiment, a graphics processing unit (GPU) is programmed to receive compressed data packets and decompress such packets in parallel. The compressed data packets are compressed representations of an image, and the lossless compression algorithm is a Rice compression algorithm.

  12. Commercial Buildings High Performance Rooftop Unit Challenge

    SciTech Connect

    2011-12-16

    The U.S. Department of Energy (DOE) and the Commercial Building Energy Alliances (CBEAs) are releasing a new design specification for high performance rooftop air conditioning units (RTUs). Manufacturers who develop RTUs based on this new specification will find strong interest from the commercial sector due to the energy and financial savings.

  13. Promising Technology: High-Efficiency Rooftop Units

    Energy.gov [DOE]

    High-efficiency rooftop air conditioning units (RTUs) can significantly reduce heating, cooling, and ventilation energy consumption. High efficiency RTUs incorporate variable speed controls to minimize fan and compressor energy while capturing and reusing heat, cold, and humidity from a building’s exhaust air.

  14. United States Atlas of Renewable Resources

    DOE Data Explorer

    The Atlas is an interactive application of the renewable energy resources in the contiguous United States, Alaska and Hawaii. It illustrates the geographic distribution of wind, solar, geothermal, and biomass resources, as well as other pertinent information such as transportation network and administrative boundaries.[Copied from http://www.nrel.gov/gis/maps.html

  15. United States Government Department of Energy

    Office of Legacy Management (LM)

    -. (8-29) EFG (07-W) United States Government Department of Energy m e m o randum DATE: b; zl3 REPLY TO Al-I-N OF: EM-421 (W. A. W illiams, 903-8149) ion of the Southern Research...

  16. Fukushima Daiichi Unit 3 MELCOR Investigation

    SciTech Connect

    Robb, Kevin R; Francis, Matthew W; Ott, Larry J

    2012-01-01

    The Department of Energy sponsored a Fukushima Daiichi accident study as a collaboration between Sandia, Oak Ridge (ORNL), and Idaho National Laboratories. The purpose of the effort was to compile relevant data, reconstruct the accident progression using computer codes, assess the codes predictive capabilities, and to identify future data needs. The following summarizes MELCOR simulations performed at ORNL on Fukushima Daiichi Unit 3.

  17. " Million U.S. Housing Units"

    Energy Information Administration (EIA) (indexed site)

    0 Home Appliances Usage Indicators by Type of Housing Unit, 2005" " Million U.S. Housing Units" ,,"Type of Housing Unit" ," Housing Units (millions) ","Single-Family Units",,"Apartments in Buildings With--" "Home Appliances Usage Indicators",,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total",111.1,72.1,7.6,7.8,16.7,6.9 "Cooking

  18. " Million U.S. Housing Units"

    Energy Information Administration (EIA) (indexed site)

    1 Home Electronics Characteristics by Type of Housing Unit, 2005" " Million U.S. Housing Units" ,,"Type of Housing Unit" ,"Housing Units (millions)","Single-Family Units",,"Apartments in Buildings With--" "Home Electronics Characteristics",,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total",111.1,72.1,7.6,7.8,16.7,6.9 "Personal

  19. " Million U.S. Housing Units"

    Energy Information Administration (EIA) (indexed site)

    2 Home Electronics Usage Indicators by Type of Housing Unit, 2005" " Million U.S. Housing Units" ,,"Type of Housing Unit" ,"Housing Units (millions)","Single-Family Units",,"Apartments in Buildings With--" "Home Electronics Usage Indicators",,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total",111.1,72.1,7.6,7.8,16.7,6.9 "Personal

  20. " Million U.S. Housing Units"

    Energy Information Administration (EIA) (indexed site)

    2 Living Space Characteristics by Type of Housing Unit, 2005" " Million U.S. Housing Units" ,,"Type of Housing Unit" ,"Housing Units (millions)","Single-Family Units",,"Apartments in Buildings With--" "Living Space Characteristics",,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total",111.1,72.1,7.6,7.8,16.7,6.9 "Floorspace (Square Feet)"

  1. " Million U.S. Housing Units"

    Energy Information Administration (EIA) (indexed site)

    4 Space Heating Characteristics by Type of Housing Unit, 2005" " Million U.S. Housing Units" ,,"Type of Housing Unit" ,"Housing Units (millions)","Single-Family Units",,"Apartments in Buildings With--" "Space Heating Characteristics",,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total",111.1,72.1,7.6,7.8,16.7,6.9 "Do Not Have Space Heating

  2. " Million U.S. Housing Units"

    Energy Information Administration (EIA) (indexed site)

    6 Air Conditioning Characteristics by Type of Housing Unit, 2005" " Million U.S. Housing Units" ,,"Type of Housing Unit" ,"Housing Units (millions)","Single-Family Units",,"Apartments in Buildings With--" "Air Conditioning Characteristics",,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total",111.1,72.1,7.6,7.8,16.7,6.9 "Do Not Have Cooling

  3. " Million U.S. Housing Units"

    Energy Information Administration (EIA) (indexed site)

    7 Air Conditioning Usage Indicators by Type of Housing Unit, 2005" " Million U.S. Housing Units" ,,"Type of Housing Unit" ,"Housing Units (millions)","Single-Family Units",,"Apartments in Buildings With--" "Air Conditioning Usage Indicators",,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total",111.1,72.1,7.6,7.8,16.7,6.9 "Do Not Have Cooling

  4. " Million U.S. Housing Units"

    Energy Information Administration (EIA) (indexed site)

    9 Home Appliances Characteristics by Type of Housing Unit, 2005" " Million U.S. Housing Units" ,,"Type of Housing Unit" ,"Housing Units (millions)","Single-Family Units",,"Apartments in Buildings With--" "Home Appliances Characteristics",,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total U.S.",111.1,72.1,7.6,7.8,16.7,6.9 "Cooking

  5. " Million U.S. Housing Units"

    Energy Information Administration (EIA) (indexed site)

    8 Water Heating Characteristics by Type of Housing Unit, 2005" " Million U.S. Housing Units" ,,"Type of Housing Unit" ,"Housing Units (millions)","Single-Family Units",,"Apartments in Buildings With--" "Water Heating Characteristics",,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total",111.1,72.1,7.6,7.8,16.7,6.9 "Number of Water

  6. Overview of AREVA Logistics Business Unit Capabilities and Expertise |

    Office of Environmental Management (EM)

    Department of Energy AREVA Logistics Business Unit Capabilities and Expertise Overview of AREVA Logistics Business Unit Capabilities and Expertise Overview of AREVA Logistics Business Unit capabilities and Expertise Overview of Transnuclear Inc Transportation Capabilities in the United States Questions Overview of AREVA Logistics Business Unit Capabilities and Expertise (941.29 KB) More Documents & Publications TEC Working Group Topic Groups Rail Key Documents Planning Subgroup

  7. Next Generation Rooftop Unit - 2013 Peer Review | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    Next Generation Rooftop Unit - 2013 Peer Review Next Generation Rooftop Unit - 2013 Peer Review Emerging Technologies Project for the 2013 Building Technologies Office's Program Peer Review emrgtech11_shen_040313.pdf (1.28 MB) More Documents & Publications A typical commercial rooftop air-conditioning unit (RTU) Credit: Oak Ridge National Lab Next Generation Rooftop Unit Rooftop Unit Suite: RTU Challenge, RTU Advanced Controls and RTU Smart Monitoring and Diagnostic System - 2013 BTO Peer

  8. United Nations geothermal activities in developing countries

    SciTech Connect

    Beredjick, N.

    1987-07-01

    The United Nations implements technical cooperation projects in developing countries through its Department of Technical Cooperation for Development (DTCD). The DTCD is mandated to explore for and develop natural resources (water, minerals, and relevant infrastructure) and energy - both conventional and new and renewable energy sources. To date, the United Nations has been involved in over 30 geothermal exploration projects (completed or underway) in 20 developing countries: 8 in Africa (Djibouti, Ethiopia, Kenya, Madagascar); 8 in Asia (China, India, Jordan, Philippines, Thailand); 9 in Latin America (Bolivia, Chile, El Salvador, Honduras, Mexico, Nicaragua, Panama) and 6 in Europe (Greece, Romania, Turkey, Yugoslavia). Today, the DTCD has seven UNDP geothermal projects in 6 developing countries. Four of these (Bolivia, China, Honduras, and Kenya) are major exploration projects whose formulation and execution has been possible thanks to the generous contributions under cost-sharing arrangements from the government of Italy. These four projects are summarized.

  9. Estimated Water Flows in 2005: United States

    SciTech Connect

    Smith, C A; Belles, R D; Simon, A J

    2011-03-16

    Flow charts depicting water use in the United States have been constructed from publicly available data and estimates of water use patterns. Approximately 410,500 million gallons per day of water are managed throughout the United States for use in farming, power production, residential, commercial, and industrial applications. Water is obtained from four major resource classes: fresh surface-water, saline (ocean) surface-water, fresh groundwater and saline (brackish) groundwater. Water that is not consumed or evaporated during its use is returned to surface bodies of water. The flow patterns are represented in a compact 'visual atlas' of 52 state-level (all 50 states in addition to Puerto Rico and the Virgin Islands) and one national water flow chart representing a comprehensive systems view of national water resources, use, and disposition.

  10. Renewable Electricity Futures for the United States

    SciTech Connect

    Mai, Trieu; Hand, Maureen; Baldwin, Sam F.; Wiser , Ryan; Brinkman, G.; Denholm, Paul; Arent, Doug; Porro, Gian; Sandor, Debra; Hostick, Donna J.; Milligan, Michael; DeMeo, Ed; Bazilian, Morgan

    2014-04-14

    This paper highlights the key results from the Renewable Electricity (RE) Futures Study. It is a detailed consideration of renewable electricity in the United States. The paper focuses on technical issues related to the operability of the U. S. electricity grid and provides initial answers to important questions about the integration of high penetrations of renewable electricity technologies from a national perspective. The results indicate that the future U. S. electricity system that is largely powered by renewable sources is possible and the further work is warranted to investigate this clean generation pathway. The central conclusion of the analysis is that renewable electricity generation from technologies that are commercially available today, in combination with a more flexible electric system, is more than adequate to supply 80% of the total U. S. electricity generation in 2050 while meeting electricity demand on an hourly basis in every region of the United States.

  11. Better Buildings Alliance, Advanced Rooftop Unit Campaign: Rooftop Unit Measurement and Verification (Fact Sheet)

    SciTech Connect

    Not Available

    2014-09-01

    This document provides facility managers and building owners an introduction to measurement and verification (M&V) methods to estimate energy and cost savings of rooftop units replacement or retrofit projects to estimate paybacks or to justify future projects.

  12. CONVERT 15 WELLS TO BORS PUMPING UNITS AND TEST/COMPARE TO CONVENTIONAL UNITS

    SciTech Connect

    Walter B. North

    2003-02-04

    A new type of fluid lifting equipment called Balanced Oil Recovery System (trade named BORS Lift{trademark}) was installed on several idle oil wells to demonstrate the operating efficiency of this innovative equipment technology. The BORS Lift system is designed to bring oil to the surface without the accompanying formation water. The BORS Lift system uses an innovative strap mechanism that takes oil from the top of the downhole oilwater column and lifts it to the surface, eliminating production of the formation water. Eliminating salt water production could potentially increase oil production, reduce operational costs, benefit the environment, and cut salt water disposal costs. Although the BORS Lift units did not function as intended, lessons learned during the course of the field demonstration project resulted in improvements in the technology and redesign of subsequent generation BORS Lift units which are reported to have significantly improved their performance characteristics. BORS Lift units were installed on 15 temporarily abandoned wells which had been shut down due to low oil production, high water production, and uneconomic operating conditions. The wells had been producing with artificial lift at a high watercut from a shallow (850-900 feet), pressure depleted oil sand reservoir prior to being shut down. The electrical motor driven BORS Lift units provided a possible approach for economically returning the shallow, low-volume oil wells to production. The BORS Lift units used in this field demonstration were designed to recover up to roughly 22 barrels of fluid per day from depths ranging to 1,700 feet, ideal for many marginal stripper well operations. The BORS units were first-production-model test units, operated under oil field conditions for the first time, and were naturally expected to experience some design problems. From the onset, the operator experienced mechanical, design, and operational problems with the BORS Lift units and was unable to

  13. Establishment of Lipolexis oregmae (Hymenoptera: Aphidiidae) in a classical biological control program directed against the brown citrus aphid (Homoptera: Aphididae) in Florida

    SciTech Connect

    Persad, A.B.; Hoy, M.A.; Ru Nguyen

    2007-03-15

    The parasitoid Lipolexis oregmae Gahan (introduced as L. scutellaris Mackauer) was imported from Guam, evaluated in quarantine, mass reared, and released into citrus groves in Florida in a classical biological control program directed against the brown citrus aphid, Toxoptera citricida Kirkaldy. Releases of 20,200, 12,100, and 1,260 adults of L. oregmae were made throughout Florida during 2000, 2001, and 2002, respectively. To determine if L. oregmae had successfully established, surveys were conducted throughout the state beginning in the summer of 2001 and continuing through the summer of 2003. Parasitism during 2001 and 2002 was evaluated by holding brown citrus aphids in the laboratory until parasitoid adults emerged. Lipolexis oregmae was found in 10 sites in 7 counties and 4 sites in 3 counties with parasitism rates ranging from 0.7 to 3.3% in 2001 and 2002, respectively. Laboratory tests indicated that high rates of mortality occurred if field-collected parasitized aphids were held in plastic bags, so a molecular assay was used that allowed immature L. oregmae to be detected within aphid hosts immediately after collection. The molecular assay was used in 2003 with the brown citrus aphids and with other aphid species collected from citrus, weeds, and vegetables near former release sites; immatures of L. oregmae were detected in black citrus aphids, cowpea aphids, spirea aphids, and melon aphids, as well as in the brown citrus aphid, in 4 of 8 counties sampled, with parasitism ranging from 2.0 to 12.9%, indicating that L. oregmae is established and widely distributed. Samples taken in Polk County during Oct 2005 indicated that L. oregmae has persisted. The ability of L. oregmae to parasitize other aphid species on citrus, and aphids on other host plants, enhances the ability of L. oregmae to persist when brown citrus aphid populations are low. (author) [Spanish] El parasitoide Lipolexis oregmae Gahan (introducido como L. scutellaris Mackauer) fue importado de

  14. CANADA-UNITED STATES REGULATORY COOPERATION COUNCIL

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    CANADA-UNITED STATES REGULATORY COOPERATION COUNCIL Webinar: Proposed Approach for Energy Efficiency Standards January 12, 2015 Natural Resources Ressources naturelles Canada Canada Key Contacts in U.S. and Canada NRCan * Debbie Scharf, Director of Equipment Division * Katherine Delves, Chief of Standards Development * Jamie Hulan, Team leader for Standards Development * Andrés Drew, RCC lead DOE * John Cymbalsky, Program Manager for Appliance Standards * Ashley Armstrong, Supervisory

  15. Sandia National Laboratories for the United States

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    XrayToolKit.com X-Ray Toolkit (XTK) is a software program developed by Sandia National Laboratories for the United States Government under funding from NNSA and TSWG. XTK is a radiograph acquisition and processing program designed specifically for Explosive Ordnance Disposal (EOD) technicians. XTK supports image acquisition from a variety of commercial scanners and provides image enhancement, measurement, and markup tools through a modern and user- friendly interface. Other features include

  16. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    8 Home Appliances in Homes in Northeast Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"Northeast Census Region" ,,,"New England Census Division",,,"Middle Atlantic Census Division" ,"Total U.S.1 (millions)",,"Total New England",,,"Total Middle Atlantic" ,,"Total Northeast",,,"CT, ME, NH, RI, VT" "Home

  17. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    8 Televisions in Homes in Northeast Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"Northeast Census Region" ,,,"New England Census Division",,,"Middle Atlantic Census Division" ,"Total U.S.1 (millions)",,"Total New England",,,"Total Middle Atlantic" ,,"Total Northeast",,,"CT, ME, NH, RI, VT"

  18. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    8 Air Conditioning in Homes in Northeast Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"Northeast Census Region" ,,,"New England Census Division",,,"Middle Atlantic Census Division" ,"Total U.S.1 (millions)",,"Total New England",,,"Total Middle Atlantic" ,,"Total Northeast",,,"CT, ME, NH, RI, VT" "Air

  19. Memorandum To: United States Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    To: United States Department of Energy Via email: expartecommunications@hq.doe.gov From: Robin Roy, Natural Resources Defense Council Date: March 24, 2016 Re: Ex Parte Communication Docket number EERE-2014-BT-STD-0031 On Wednesday March 23, 2016, representatives of the American Gas Association (AGA) and the Natural Resources Defense Council (NRDC) spoke by telephone with representatives of the Department of Energy (DOE) to discuss energy conservation standards for residential furnaces. See

  20. The United States natural gas industry

    SciTech Connect

    Gibson, D.E.

    1988-01-01

    The U.S. natural gas industry can only be understood within the context of the nation's attitudes toward the proper role of government within the U.S. economy. A review of regulatory history provides valuable insights to understanding the unique structure and functioning of the gas industry in the United States, as well as future directions for the industry. Tomorrow's natural gas industry will feature adequate gas supplies, unbundling of services, continuing competition with oil, and changed regulation.

  1. Microbial-enhanced waterflooding; Mink Unit project--

    SciTech Connect

    Bryant, R.S.; Burchfield, T.E. , Bartlesville, OK ); Dennis, M. ); Hitzman, D.O. )

    1990-02-01

    This paper reports on a microbial-enhanced waterflooding field project conducted in the Mink unit of the Delaware-Childers field in Nowata County, OK. A microbial formulation was injected into four injection wells and has been followed by periodic injections of molasses as nutrient. Laboratory and field procedures that were used to design the test are described. Improvements in both oil production rate and WOR's have been observed.

  2. The United States has significant natural gas

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    United States has significant natural gas and oil reserves. But many of these resources are increasingly harder to locate and bring into production. To help meet this challenge, the U.S. Department of Energy's Office of Fossil Energy over the years has amassed wide ranging expertise in areas related to deepwater resource location, production, safety and environmental protection. The goal of these activities has been to not only help overcome production and technical hurdles, but also improve the

  3. United States Government Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    k08-93) United States Government Department of Energy memorandum DATE: September 23, 2004 Audit Report Number: OAS-L-04-23 REPLY TO ATTN OF: IG-32 (A03SR041) SUBJECT: Audit of the National Nuclear Security Administration's Tritium Production Plan TO: Administrator, National Nuclear Security Administration INTRODUCTION AND OBJECTIVE The Department of Energy's National Nuclear Security Administration (NNSA) is responsible for maintaining and enhancing the nation's nuclear weapons stockpile, of

  4. United States Government Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    e Electrons Form Approved by ClLR - 70/0#2002 (08-89) United States Government Department of Energy - nemorandum Bonneville Power Administration DATE: January 31, 201 1 REPLY TO AITN OF: BPA-KEC-4 SUBJECT: 201 1 Annual National Environmental Policy Act (NEPA) Planning Summary TO: Scott Blake Harris, General Counsel Attached please find Bonneville Power Administration's (BPA's) 201 1 Annual NEPA Planning Summary. As requested in your December 8,2010, memorandum, the summary identifies the status

  5. Data report TRUPACT-I, Unit 0

    SciTech Connect

    Mihalovich, G.S.; Hudson, M.; Joseph, B.J.; Romesberg, L.E.

    1985-09-01

    TRUPACT-I was tested to evaluate the design under the regulatory testing requirements defined in DOE Order No. 5480.1, Chapter 3. Tests were conducted both at the Drop Test Facility at Oak Ridge National Laboratories, Oak Ridge, Tennessee, and at Sandia National Laboratories, Albuquerque, New Mexico. The program consisted of 12-inch and 30-foot drop tests onto an essentially unyielding surface, 40-inch drop tests onto a puncture bar, and a thermal test. Instrumentation for the tests included accelerometers, strain gages, and thermocouples. Data from each test was stored on magnetic tape for later analysis. The test unit met all of the structural regulatory requirements during the impact events, with the possible exception of damage to the seal retainer bond line discovered during disassembly. The adhesive bonds on the seal retainer did not hold after the thermal test. The foam behind the puncture panel on the outer door burned during the thermal test, overheating and deteriorating the seals; the seals failed. This report presents the raw data from the testing program of TRUPACT-I, Unit 0. An analysis report interpreting the data will be published as ''TRUPACT-I, Unit 0 Test Data Analysis,'' SAND85-0943 (TTC-0555), Sandia National Laboratories, Albuquerque, New Mexico.

  6. Table HC1-5a. Housing Unit Characteristics by Type of Owner-Occupied Housing Unit,

    Energy Information Administration (EIA) (indexed site)

    5a. Housing Unit Characteristics by Type of Owner-Occupied Housing Unit, Million U.S. Households, 2001 Housing Unit Characteristics RSE Column Factor: Total Owner- Occupied Units Type of Owner-Occupied Housing Unit RSE Row Factors Single-Family Apartments in Buildings With Mobile Homes Two to Four Units Five or More Units 0.4 0.4 1.8 2.1 1.4 Total ............................................... 72.7 63.2 2.1 1.8 5.7 6.7 Census Region and Division Northeast ......................................

  7. 3610 Collins Ferry Road, P.O. Box 880, Morgantown, WV 26507

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    MEMORANDUM FOR NEPA FILE FROM: MARK LUSK NEPA DOCUMENT MANAGER SUBJECT: Supplement Analysis for the Exide Technologies' Proposed Project under the Electric Drive Vehicle Battery ...

  8. Adaptation of telecobalt unit for stereotactic irradiation

    SciTech Connect

    Singh, I. Rabi Raja . E-mail: rabiraja@cmcvellore.ac.in; Ravindran, B. Paul; Ayyangar, K.M.

    2007-04-01

    We investigated the feasibility of using an isocentric telecobalt unit for advanced treatment techniques, such as stereotactic radiotherapy. To adapt the telecobalt unit (Th780 C) for stereotactic irradiation, collimator inserts of various sizes, collimator mount, and a couch mount suitable for the telecobalt unit were developed, and the characteristics of the narrow beams of Cobalt-60 ({sup 60}Co) were studied. Comparative study was carried out between the stereotactic radiotherapy plans of 6 MV and {sup 60}Co beams using a 3-dimensional (3D) treatment planning system. The beam penumbra of {sup 60}Co beams was found to be larger than those of 6 MV beams. The dose-volume histograms (DVH) obtained from the {sup 60}Co beam plan were comparable to those obtained from the 6 MV plan. The DVH of nontarget tissue obtained from the plans of the 2 beams were found to be in good agreement to each other. The difference in equivalent fall-off distance (EFOD) for all 3 cases was found insignificant; hence, it can be concluded that the fall-off dose in the dose distribution of the {sup 60}Co stereotactic plan is as good as that of the 6 MV stereotactic plan. In all 3 cases for which the treatment plans were compared between {sup 60}Co and 6 MV beams, it was observed that the fall-off doses outside the target were similar; therefore, considering {sup 60}Co with 5-mm margin is a cost effective alternative for the linac-based stereotactic radiotherapy.

  9. Shipping device for heater unit assembly

    DOEpatents

    Blaushild, Ronald M.; Abbott, Stephan L.; Miller, Phillip E.; Shaffer, Robert

    1991-01-01

    A shipping device for a heater unit assembly (23), the heater unit assembly (23) including a cylindrical wall (25) and a top plate (31) secured to the cylindrical wall (25) and having a flange portion which projects radially beyond the outer surface of the cylindrical wall (25), and the shipping device including: a cylindrical container (3) having a closed bottom (13); a support member (47) secured to the container (3) and having an inwardly directed flange for supporting the flange portion of the top plate (31); a supplemental supporting system (1) for positioning the heater unit assembly (23) in the container (3) at a spaced relation from the inner surface and bottom wall (13) of the container (3); a cover (15) for closing the top of the container (3); and a container supporting structure (5,7,8) supporting the container (3) in a manner to permit the container (3) to be moved, relative to the supporting structure (5,7,8 ), between a vertical position for loading and unloading the assembly (23) and a horizontal position for transport of the assembly (23). A seal (57) is interposed between the container (3) and the cover (15) for sealing the interior of the container (3) from the environment. An abutment member (41) is mounted on the container supporting structure (5,7,8) for supporting the container bottom (13), when the container (3) is in the vertical position, to prevent the container (3) from moving past the vertical position in the direction away from the horizontal position, and a retainer member (55) is secured within the cover (15) for retaining the assembly top plate (31) in contact with the support member (47) when the cover (15) closes the top of the container (3).

  10. Floating production unit to work off Brazil

    SciTech Connect

    Not Available

    1992-10-19

    This paper reports that Petroleo Brasileiro SA expects by early November to deploy its Petrobras XXIV floating production unit (FPU) in about 900 ft of water in Albacora field off Brazil. The FPU was scheduled to depart Galveston, Tex., this month, following completion of modifications and upgrades under a turnkey contract with Chiles Offshore International Inc. Chiles began modifying Petrobras XXIV about 1 year ago as part of a deal closed in October 1991 in which Chiles Offshore Corp. sold the vessel, then known as Intrepid, to Brasoil, the international subsidiary of Petrobras.

  11. Rooftop Unit Comparison Calculator User Manual

    SciTech Connect

    Miller, James D.

    2015-04-30

    This document serves as a user manual for the Packaged rooftop air conditioners and heat pump units comparison calculator (RTUCC) and is an aggregation of the calculator’s website documentation. Content ranges from new-user guide material like the “Quick Start” to the more technical/algorithmic descriptions of the “Methods Pages.” There is also a section listing all the context-help topics that support the features on the “Controls” page. The appendix has a discussion of the EnergyPlus runs that supported the development of the building-response models.

  12. CT. L-2 United States Government

    Office of Legacy Management (LM)

    DOE F 7325.8 (a-a9J - EFG (OMOJ CT. L-2 United States Government 8 ",> I,: Ti -& d .- " * memorandum (' -. r_l DATE: AUG 10 1993 REPLY TO ATTN OF: EM-421 (W. Williams, 903-8149) SUSJECT: Hazard Assessment for Radioactive Contamination at the Seymour Site, Seymour, Connecticut To' L. Price, OR - We have reviewed the Hazard Assessment for the Radioactive Contamination at the Sevmour Site. Sevmour, Connecticut dated May 1993. This hazard assessment is related to residual

  13. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    1 Space Heating in U.S. Homes in West Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"West Census Region" ,,,"Mountain Census Division",,,,,,,"Pacific Census Division" ,,,,"Mountain North Sub-Division",,,"Mountain South Sub-Division" ,"Total U.S.1 (millions)",,,"Total Mountain North",,,"Total Mountain South" ,,"Total West","Total Mountain",,,"ID, MT, UT,

  14. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    0 Structural and Geographic Characteristics of Homes in South Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"South Census Region" ,,,"South Atlantic Census Division",,,,,,"East South Central Census Division",,,"West South Central Census Division" ,,,,,,,,,"Total East South Central",,,"Total West South Central" ,"Total U.S.1 (millions)",,"Total South Atlantic" "Structural

  15. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    1 Structural and Geographic Characteristics of Homes in West Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"West Census Region" ,,,"Mountain Census Division",,,,,,,"Pacific Census Division" ,,,,"Mountain North Sub-Division",,,"Mountain South Sub-Division" ,"Total U.S.1 (millions)",,,"Total Mountain North",,,"Total Mountain South" "Structural and Geographic

  16. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    1 Appliances in Homes in West Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"West Census Region" ,,,"Mountain Census Division",,,,,,,"Pacific Census Division" ,,,,"Mountain North Sub-Division",,,"Mountain South Sub-Division" ,"Total U.S.1 (millions)",,,"Total Mountain North",,,"Total Mountain South" ,,"Total West","Total Mountain",,,"ID, MT, UT,

  17. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    0 Televisions in Homes in South Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"South Census Region" ,,,"South Atlantic Census Division",,,,,,"East South Central Census Division",,,"West South Central Census Division" ,,,,,,,,,"Total East South Central",,,"Total West South Central" ,"Total U.S.1 (millions)",,"Total South Atlantic" ,,"Total South",,,,,"DC, DE, MD,

  18. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    1 Televisions in Homes in West Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"West Census Region" ,,,"Mountain Census Division",,,,,,,"Pacific Census Division" ,,,,"Mountain North Sub-Division",,,"Mountain South Sub-Division" ,"Total U.S.1 (millions)",,,"Total Mountain North",,,"Total Mountain South" ,,"Total West","Total Mountain",,,"ID, MT, UT,

  19. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    0 Computers and Other Electronics in Homes in South Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"South Census Region" ,,,"South Atlantic Census Division",,,,,,"East South Central Census Division",,,"West South Central Census Division" ,,,,,,,,,"Total East South Central",,,"Total West South Central" ,"Total U.S.1 (millions)",,"Total South Atlantic" ,,"Total

  20. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    1 Computers and Other Electronics in Homes in West Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"West Census Region" ,,,"Mountain Census Division",,,,,,,"Pacific Census Division" ,,,,"Mountain North Sub-Division",,,"Mountain South Sub-Division" ,"Total U.S.1 (millions)",,,"Total Mountain North",,,"Total Mountain South" ,,"Total West","Total

  1. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    0 Water Heating in U.S. Homes in South Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"South Census Region" ,,,"South Atlantic Census Division",,,,,,"East South Central Census Division",,,"West South Central Census Division" ,,,,,,,,,"Total East South Central",,,"Total West South Central" ,"Total U.S.1 (millions)",,"Total South Atlantic" ,,"Total South",,,,,"DC,

  2. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    11 Water Heating in U.S. Homes in West Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"West Census Region" ,,,"Mountain Census Division",,,,,,,"Pacific Census Division" ,,,,"Mountain North Sub-Division",,,"Mountain South Sub-Division" ,"Total U.S.1 (millions)",,,"Total Mountain North",,,"Total Mountain South" ,,"Total West","Total Mountain",,,"ID, MT,

  3. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    0 Appliances in Homes in South Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"South Census Region" ,,,"South Atlantic Census Division",,,,,,"East South Central Census Division",,,"West South Central Census Division" ,,,,,,,,,"Total East South Central",,,"Total West South Central" ,"Total U.S.1 (millions)",,"Total South Atlantic" ,,"Total South",,,,,"DC, DE, MD,

  4. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    0 Air Conditioning in Homes in South Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"South Census Region" ,,,"South Atlantic Census Division",,,,,,"East South Central Census Division",,,"West South Central Census Division" ,,,,,,,,,"Total East South Central",,,"Total West South Central" ,"Total U.S.1 (millions)",,"Total South Atlantic" ,,"Total South",,,,,"DC, DE,

  5. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    6 Fuels Used and End Uses in U.S. Homes, by Climate Region, 2009" " Million Housing Units, Final" ,,"Climate Region2" ,"Total U.S.1 (millions)" ,,"Very Cold/","Mixed- Humid","Mixed-Dry/" "Fuels Used and End Uses",,"Cold",,"Hot-Dry","Hot-Humid","Marine" "Total Homes",113.6,38.8,35.4,14.1,19.1,6.3 "Fuels Used for Any Use"

  6. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    4 Structural and Geographic Characteristics of U.S. Homes, by Number of Household Members, 2009" " Million Housing Units, Final" ,,"Number of Household Members" ,"Total U.S.1 (millions)" "Structural and Geographic Characteristics",,,,,,"5 or More Members" ,,"1 Member","2 Members","3 Members","4 Members" "Total Homes",113.6,31.3,35.8,18.1,15.7,12.7 "Census Region and Division"

  7. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    8 Structural and Geographic Characteristics of Homes in Northeast Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"Northeast Census Region" ,,,"New England Census Division",,,"Middle Atlantic Census Division" ,"Total U.S.1 (millions)",,"Total New England",,,"Total Middle Atlantic" "Structural and Geographic Characteristics",,"Total Northeast",,,"CT, ME, NH, RI, VT"

  8. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    9 Structural and Geographic Characteristics of Homes in Midwest Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"Midwest Census Region" ,,,"East North Central Census Division",,,,,"West North Central Census Division" ,,,"Total East North Central",,,,,"Total West North Central" ,"Total U.S.1 (millions)" "Structural and Geographic Characteristics",,"Total Midwest",,,,," IN,

  9. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    9 Appliances in Homes in Midwest Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"Midwest Census Region" ,,,"East North Central Census Division",,,,,"West North Central Census Division" ,,,"Total East North Central",,,,,"Total West North Central" ,"Total U.S.1 (millions)" ,,"Total Midwest",,,,," IN, OH",,,"IA, MN, ND, SD"

  10. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    6 Televisions in U.S. Homes, by Climate Region, 2009" " Million Housing Units, Final" ,,"Climate Region2" ,"Total U.S.1 (millions)" ,,"Very Cold/","Mixed- Humid","Mixed-Dry/" "Televisions",,"Cold",,"Hot-Dry","Hot-Humid","Marine" "Total Homes",113.6,38.8,35.4,14.1,19.1,6.3 "Televisions" "Number of Televisions" 0,1.5,0.6,0.4,0.2,0.2,0.2

  11. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    HC4.9 Televisions in Homes in Midwest Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"Midwest Census Region" ,,,"East North Central Census Division",,,,,"West North Central Census Division" ,,,"Total East North Central",,,,,"Total West North Central" ,"Total U.S.1 (millions)" ,,"Total Midwest",,,,," IN, OH",,,"IA, MN, ND, SD"

  12. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    4 Computers and Other Electronics in U.S. Homes, by Number of Household Members, 2009" " Million Housing Units, Final" ,,"Number of Household Members" ,"Total U.S.1 (millions)" ,,,,,,"5 or More Members" "Computers and Other Electronics",,"1 Member","2 Members","3 Members","4 Members" "Total Homes",113.6,31.3,35.8,18.1,15.7,12.7 "Computers" "Number of Computers"

  13. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    8 Computers and Other Electronics in Homes in Northeast Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"Northeast Census Region" ,,,"New England Census Division",,,"Middle Atlantic Census Division" ,"Total U.S.1 (millions)",,"Total New England",,,"Total Middle Atlantic" ,,"Total Northeast",,,"CT, ME, NH, RI, VT" "Computers and Other

  14. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    9 Computers and Other Electronics in Homes in Midwest Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"Midwest Census Region" ,,,"East North Central Census Division",,,,,"West North Central Census Division" ,,,"Total East North Central",,,,,"Total West North Central" ,"Total U.S.1 (millions)" ,,"Total Midwest",,,,," IN, OH",,,"IA, MN, ND, SD" "Computers and Other

  15. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    8 Space Heating in U.S. Homes in Northeast Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"Northeast Census Region" ,,,"New England Census Division",,,"Middle Atlantic Census Division" ,"Total U.S.1 (millions)",,"Total New England",,,"Total Middle Atlantic" ,,"Total Northeast",,,"CT, ME, NH, RI, VT" "Space

  16. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    9 Space Heating in U.S. Homes in Midwest Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"Midwest Census Region" " ",,,"East North Central Census Division",,,,,"West North Central Census Division" ,,,"Total East North Central",,,,,"Total West North Central" ,"Total U.S.1 (millions)" ,,"Total Midwest",,,,," IN, OH",,,"IA, MN, ND, SD" "Space

  17. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    8 Water Heating in U.S. Homes in Northeast Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"Northeast Census Region" ,,,"New England Census Division",,,"Middle Atlantic Census Division" ,"Total U.S.1 (millions)",,"Total New England",,,"Total Middle Atlantic" ,,"Total Northeast",,,"CT, ME, NH, RI, VT" "Water

  18. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    9 Water Heating in U.S. Homes in Midwest Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"Midwest Census Region" ,,,"East North Central Census Division",,,,,"West North Central Census Division" ,,,"Total East North Central",,,,,"Total West North Central" ,"Total U.S.1 (millions)" ,,"Total Midwest",,,,,,,,"IA, MN, ND, SD" "Water

  19. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    4 Fuels Used and End Uses in U.S. Homes, by Number of Household Members, 2009" " Million Housing Units, Final" ,,"Number of Household Members" ,"Total U.S.1 (millions)" ,,,,,,"5 or More Members" "Fuels Used and End Uses",,"1 Member","2 Members","3 Members","4 Members" "Total Homes",113.6,31.3,35.8,18.1,15.7,12.7 "Fuels Used for Any Use"

  20. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    3 Structural and Geographic Characteristics of U.S. Homes, by Year of Construction, 2009" " Million Housing Units, Final" ,,"Year of Construction" ,"Total U.S.1 (millions)" "Structural and Geographic Characteristics",,"Before 1940","1940 to 1949","1950 to 1959","1960 to 1969","1970 to 1979","1980 to 1989","1990 to 1999","2000 to 2009" "Total

  1. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    6 Structural and Geographic Characteristics of U.S. Homes, by Climate Region, 2009" " Million Housing Units, Final" ,,"Climate Region2" ,"Total U.S.1 (millions)" "Structural and Geographic Characteristics",,"Very Cold/","Mixed- Humid","Mixed-Dry/" ,,"Cold",,"Hot-Dry","Hot-Humid","Marine" "Total Homes",113.6,38.8,35.4,14.1,19.1,6.3 "Census Region and Division"

  2. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    7 Structural and Geographic Characteristics of U.S. Homes, by Census Region, 2009" " Million Housing Units, Final" ,,"Census Region" ,"Total U.S.1 (millions)" "Structural and Geographic Characteristics",,"Northeast","Midwest","South","West" "Total Homes",113.6,20.8,25.9,42.1,24.8 "Urban and Rural2" "Urban",88.1,18,19.9,28.6,21.5 "Rural",25.5,2.8,6,13.4,3.3

  3. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    3 Computers and Other Electronics in U.S. Homes, by Year of Construction, 2009" " Million Housing Units, Final" ,,"Year of Construction" ,"Total U.S.1 (millions)" ,,"Before 1940","1940 to 1949","1950 to 1959","1960 to 1969","1970 to 1979","1980 to 1989","1990 to 1999","2000 to 2009" "Computers and Other Electronics" "Total

  4. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    4 Space Heating in U.S. Homes, by Number of Household Members, 2009" " Million Housing Units, Final" ,,"Number of Household Members" ,"Total U.S.1 (millions)" ,,,,,,"5 or More Members" "Space Heating",,"1 Member","2 Members","3 Members","4 Members" "Total Homes",113.6,31.3,35.8,18.1,15.7,12.7 "Space Heating Equipment" "Use Space Heating

  5. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    4 Air Conditioning in U.S. Homes, by Number of Household Members, 2009" " Million Housing Units, Final" ,,"Number of Household Members" ,"Total U.S.1 (millions)" ,,,,,,"5 or More Members" "Air Conditioning",,"1 Member","2 Members","3 Members","4 Members" "Total Homes",113.6,31.3,35.8,18.1,15.7,12.7 "Air Conditioning Equipment" "Use Air Conditioning

  6. " Million Housing Units, Final"

    Energy Information Administration (EIA) (indexed site)

    9 Air Conditioning in Homes in Midwest Region, Divisions, and States, 2009" " Million Housing Units, Final" ,,"Midwest Census Region" ,,,"East North Central Census Division",,,,,"West North Central Census Division" ,,,"Total East North Central",,,,,"Total West North Central" ,"Total U.S.1 (millions)" ,,"Total Midwest",,,,," IN, OH",,,"IA, MN, ND, SD" "Air

  7. United States Government Department of Energy

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    675 (03/99) United States Government Department of Energy memorandum Office of River Protection DATE: AUG 2 6 2009 REPLY TO AUTN OF: ORP:TRW 09-ORP-014 SUBJECT: FISCAL YEAR (FY) 2011 ENVIRONMENTAL MANAGEMENT BUDGET REQUEST SUBMITTAL FOR THE U.S. DEPARTMENT OF ENERGY (DOE), OFFICE OF RIVER PROTECTION (ORP) TO: Ineg R. Triay, Assistant Secretary for Environmental Management, EM- 1, HQ ORP is requesting $1,092 M for FY 2011 budget funding. This request is consistent with the Hanford Federal

  8. Coastal ecosystems of the southeastern United States

    SciTech Connect

    Carey, R.C.; Markovits, P.S.; Kirkwood, J.B.

    1981-02-01

    The purpose of the workshop was to provide training on recent developments in understanding coastal ecosystems in the southeastern United States for Fish and Wildlife Service (FWS) field personnel and other natural resource managers in the region. Major emphasis was given to three types of systems: marshes, mangroves, and sea grasses. Other systems such as coral reefs, mud flats, bottomland hardwoods, and estuaries were discussed in less detail. Twenty-three papers were presented during the workshop. One of these was abstracted and indexed individually for EDB/ERA.

  9. The United States Plutonium Balance, 1944 - 2009

    National Nuclear Security Administration (NNSA)

    Rocky Flats Site 1995 Rocky Flats Site 2005 Rocky Flats Site 1995 The United States Plutonium Balance, 1944 - 2009 An update of Plutonium: The First 50 Years, DOE/DP-0137, February 1996 June 2012 ii Preface This report updates Plutonium: The first 50 years which was released by the U.S. Department of Energy (DOE) in 1996. The topic of both reports is plutonium, sometimes referred to as Pu-239, which is capable of sustaining a nuclear chain reaction and is used in nuclear weapons and for nuclear

  10. UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGION

    U.S. Department of Energy (DOE) - all webpages (Extended Search)

    ENVIRONMENTAL PROTECTION AGENCY REGION 6 1445 ROSS AVENUE, SU ITE 1200 DALLAS TX 75202-2733 HAY *2 1 2013 CERTIFIED MAIL- RETURN RECEIPT REQUESTED Jose R. Franco Manager U.S. Department of Energy Carlsbad Field Office P.O. Box 3090 Carlsbad, NM 8822 1 RE: United States Environmental Protection Agency (EPA) Region 6 Re-authorization Approval to the Waste Isolation Pilot Plant (WIPP) for the Storage and Disposal of Polychlorinated Biphenyls (PCBs) at this Plant Located in Carlsbad, New Mexico.

  11. Figure F1. United States Census Divisions

    Gasoline and Diesel Fuel Update

    53 Figure 17. Natural gas delivered to consumers in the United States, 2015 Volumes in Million Cubic Feet Trillion Cubic Feet trillion cubic feet All Other States Wisconsin Indiana Texas Pennsylvania New Jersey Ohio Michigan Illinois California New York 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Residential All Other States Minnesota Massachusetts Pennsylvania New Jersey Ohio Michigan Texas Illinois California New York 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Commercial trillion cubic feet Res idential 4,609,670

  12. United States Government Department of Ener

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    ZZ/Ub IUE UU:-3 FAAL 423 241 3897 UIG ** HQU 10oo1 S OEF 1325.8 to-o)Dp m Ene United States Government Department of Ener memorandum DATE: November 21, 2005 Audit Report Number: OAS-L-06-02 REPLY TO ATTN OF: IG-36 (A0SOR016) SUBJECT: Audit of "Property Transfers at the East Tennessee Technology Park" TO: Gerald Boyd, Manager, Oak Ridge Ollice INTRODUCTION AND OBJECTIVE In 1999, the Oak Ridge Office (Oak Ridge) implemented a personal, property title transfer strategy at the East

  13. United States Government Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    B (06-93) United States Government Department of Energy memorandum DATE: Septerriber 7, 2006 Audit Report Number: OAS-L-06-19 R.F.1'! .. YTO A-rl"N OF: IG-32 (A06CH002) suorncr: Audit of the Department's Hydrogen Projects To: Assistant Secretaiy for Energy Efficiency and Renewable Energy INTRODUCTION AND 013JECTIVE The Department of Energy's (Department) Otllce of"~n~rgy Efficiency and Renewable Energy h3s several programs which are designed to enable the transition to the future

  14. United States Government Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    : 1325.8 ./ (8-89) iEFG (07-90) United States Government Department of Energy memorandum DATE: October 18, 2006 Audit Report Number: OAS-L-07-02 REPLY TO ATTN OF: IG-32 (A06LL041) SUBJECT: Audit Report on "Emergency Response Training at Lawrence Livermore National Laboratory" TO: Manager, Livermore Site Office, National Nuclear Security Administration INTRODUCTION AND OBJECTIVE The Secretary of Energy (Secretary) identified the safety of employees and the communities surrounding the

  15. United States Government Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    DO F 1325.8 (8-89) EFG (07-90) United States Government Department of Energy memorandum DATE: December 18, 2006 Report Number: OAS-L-07-04 REPLY TO ATTN OF: IG-32 (A07LL039) SUBJECT: Report on "Inquiry to the Hotline Complaint on Possible Design Mistakes and Cost Overruns of the Linac Coherent Light Source Project at Stanford Linear Accelerator Center" TO: Manager, Stanford Site Office INTRODUCTION AND OBJECTIVE The purpose of the Stanford Linear Accelerator Center (SLAC) Linac

  16. United States Government Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    DOEF' " ,)5.8 (08-93") * United States Government Department of Energy memorandum DATE: November 27, 2002 OAS-L-03-06 REPLY TO ATTN OF: IG-35 (A02LA042/A02LL019) SUBJECT: Audit of "Recruitment and Retention at the Los Alamos and Lawrence Livermore National Laboratories" TO: Administrator, National Nuclear Security Administration INTRODUCTION AND OBJECTIVE The U.S. Nuclear Weapons Program's mission of maintaining a safe and reliable nuclear weapons stockpile relies on the

  17. United States Government Department of Energy Memorandum

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    9/25/03 THU_13:54 FAX 423 241 3897 OIG *-- HQ @002 DOxR F 1325.8 E -' (07.90) ' United States Government Department of Energy Memorandum DATE: September 25, 2003 REPLY TO IG-36 (A03SR035) Audit Report No.: OAS-L-03-22 ATTN OF: SUBJECT: Audit of Relocation of Administrative Personnel from A-Area to B-Area at the Savannah River Site TO; Jeffrey M. Allison, Manager, Savannah River Operations Office INTRODUCTION AND OBJECTIVE In an effort to reduce operating costs at the Savannah River Site, the

  18. United States Government Department of Energy Memorandum

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    3/03 THU 13:41 FAX 865 576 3213 OAK RIDGE AUDIT A4- AIGA 0002 (8.89) EFG (07-0) United States Government Department of Energy Memorandum DATE: November 4, 2003 REPLY TO IG-36 (A03RL018) Audit Report No.: OAS-L-04-03 ATTN OF: SUBJECT: Audit of Accelerated Remediation of Tank Waste at Hanford TO: Roy J. Schepens, Manager, Office of River Protection INTRODUCTION AND OBJECTIVE Millions of gallons of radioactive waste, the result of decades of plutonium production, are stored in underground tanks at

  19. United States Government Department of Energy Memorandum

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    .25.8 (08-93) United States Government Department of Energy Memorandum DATE: August 12, 2004 REPLY TO ATTN OF: IG-30 (A04TG039) Audit Report No.: OAS-L-04-19 SUBJECT: Interim Report on Audit of "The Department's Implementation of I-MANAGE STARS" TO: Chairpersons, I-MANAGE Executive Steering Committee The purpose of the report is to provide you with observations made during our ongoing audit of the Department of Energy's (Department) implementation of the Integrated Management

  20. United States Government Department of Eney

    Office of Energy Efficiency and Renewable Energy (EERE) (indexed site)

    l 'vl/OU Wy) :jJ. rI A o Aooa IUL u. * * .. - DOE F 13218 United States Government Department of Eney memorandum DATE: November 28, 2006 Audit Report Number: OAS-L-07-03 REPLY TO ATT OF: IG-32 (A06PR022) SUBJECT: Audit of the "Department of Energy's Carbon Sequestration Program" TO: Assistant Secretary, Office of Fossil Energy INTRODUCTION AND OBJECTIVE Carbon sequestration is the capture and storage of carbon dioxide and other greenhouse gases that would otherwise be emitted into the