You need JavaScript to view this

Comparative discussion of the activated sludge and packed bed techniques in biological sewage water cleaning; Vergleichende Betrachtung von Belebungs- und Festbettverfahren fuer die biologische Abwasserreinigung

Journal Article:

Abstract

It is reasonable to state that, given proper planning, erection and careful operation, both activated sludge plants and packed bed reactors with a biofilm are capable of meeting extremely high demands on the quality of the effluent. What was to be shown is the fact that operating behaviour and demands on measurement and control techniques differ considerably. Rating depends on different criteria, according to the technique chosen, and also cost calculation is largely determined in each case by special local conditions. All this makes it difficult to compare solutions with one another or to transfer experience gathered in one plant to another application. So the choice of the best possible method in a given case remains an interesting task.- One must try to make as objective a comparison as possible of different solutions according to the relevant criteria, beyond what is quantifiable merely in terms of finance.- Any decision taken on the basis of such a comparison is bound to reflect also the values that the decision-makers hold. But it should always be possible when taking decisions about processes to leave ideology out of consideration. (orig.) [Deutsch] Es kann festgestellt werden, dass sowohl Belebungsanlagen wie auch Biofilmreaktoren bei richtiger Planung,  More>>
Authors:
Kroiss, H [1] 
  1. Technische Univ., Vienna (Germany). Inst. fuer Wasserguete und Abfallwirtschaft
Publication Date:
Dec 31, 1994
Product Type:
Journal Article
Reference Number:
SCA: 320604; 320305; PA: DE-95:0GG809; EDB-95:118108; SN: 95001443182
Resource Relation:
Journal Name: Abwassertechnik (1983); Journal Volume: 45; Journal Issue: 4; Other Information: PBD: 1994
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; BIOREACTORS; COMPARATIVE EVALUATIONS; ACTIVATED SLUDGE PROCESS; PACKED BEDS; NITRIFICATION; DENITRIFICATION; PHOSPHORUS COMPOUNDS; TEMPERATURE DEPENDENCE; OPTIMIZATION; DIFFUSION; KINETICS; ACID NEUTRALIZING CAPACITY
OSTI ID:
88311
Country of Origin:
Germany
Language:
German
Other Identifying Numbers:
Journal ID: AABRES; ISSN 0932-3708; TRN: DE95GG809
Submitting Site:
DE
Size:
pp. 51-56
Announcement Date:

Journal Article:

Citation Formats

Kroiss, H. Comparative discussion of the activated sludge and packed bed techniques in biological sewage water cleaning; Vergleichende Betrachtung von Belebungs- und Festbettverfahren fuer die biologische Abwasserreinigung. Germany: N. p., 1994. Web.
Kroiss, H. Comparative discussion of the activated sludge and packed bed techniques in biological sewage water cleaning; Vergleichende Betrachtung von Belebungs- und Festbettverfahren fuer die biologische Abwasserreinigung. Germany.
Kroiss, H. 1994. "Comparative discussion of the activated sludge and packed bed techniques in biological sewage water cleaning; Vergleichende Betrachtung von Belebungs- und Festbettverfahren fuer die biologische Abwasserreinigung." Germany.
@misc{etde_88311,
title = {Comparative discussion of the activated sludge and packed bed techniques in biological sewage water cleaning; Vergleichende Betrachtung von Belebungs- und Festbettverfahren fuer die biologische Abwasserreinigung}
author = {Kroiss, H}
abstractNote = {It is reasonable to state that, given proper planning, erection and careful operation, both activated sludge plants and packed bed reactors with a biofilm are capable of meeting extremely high demands on the quality of the effluent. What was to be shown is the fact that operating behaviour and demands on measurement and control techniques differ considerably. Rating depends on different criteria, according to the technique chosen, and also cost calculation is largely determined in each case by special local conditions. All this makes it difficult to compare solutions with one another or to transfer experience gathered in one plant to another application. So the choice of the best possible method in a given case remains an interesting task.- One must try to make as objective a comparison as possible of different solutions according to the relevant criteria, beyond what is quantifiable merely in terms of finance.- Any decision taken on the basis of such a comparison is bound to reflect also the values that the decision-makers hold. But it should always be possible when taking decisions about processes to leave ideology out of consideration. (orig.) [Deutsch] Es kann festgestellt werden, dass sowohl Belebungsanlagen wie auch Biofilmreaktoren bei richtiger Planung, Errichtung und sorgfaeltigem Betrieb in der Lage sind, auch extrem hohe Ansprueche an die Ablaufguete zu erfuellen. Was gezeigt werden sollte, ist der Umstand, dass erhebliche Unterschiede im Betriebsverhalten und in den Anforderungen an die Mess- und Regeltechnik bestehen. Fuer die Bemessung sind je nach Verfahren andere Kriterien massgebend, und auch fuer die Kostenrechnung gilt, dass die speziellen oertlichen Bedingung bei jedem Anwendungsfall von ausschlaggebender Bedeutung sind. Das alles hat zur Folge, dass es sehr schwierig ist, verschiedene Loesungsmoeglichkeiten miteinander zur vergleichen, oder die Erfahrung von einer Anlage auf einen anderen Anwendungsfall zu uebertragen. Die Auswahl des ``besten`` Verfahrens fuer deren Anwendungsfall bleibt also eine reizvolle Aufgabe. Man muss versuchen, den Vergleich von verschiedenen Loesungen nach allen massgebenden Kriterien so objektiv wie moeglich zu gestalten und sich nicht nur auf die finanziell quantifizierbaren beschraenken. Die Entscheidung, die schliesslich auf der Basis eines solchen Vergleiches gefaellt werden muss, ist notgedrungen auch von Wertvorstellungen der Entscheidenden abhaengig. Es muss jedoch immer erreicht werden koennen, dass Verfahrensentscheidungen nicht auf der Grundlage von Ideologiediskussionen gefaellt werden. (orig.)}
journal = {Abwassertechnik (1983)}
issue = {4}
volume = {45}
journal type = {AC}
place = {Germany}
year = {1994}
month = {Dec}
}