Methods of calibrating control rods with particular reference to irradiated CAGR are surveyed. Some systematic spatial effects are found and an estimate of their magnitude made. It is concluded that control rod oscillation provides a promising method of calibrating rods at power which is as yet untried on CAGR. Also the rod drop using inverse kinetics provides a rod calibration but spatial effects may be large and these would be difficult to correct theoretically. The pulsed neutron technique provides a calibration route with small errors due to spatial effects provided a suitable K-tube can be developed. The xenon transient method is shown to have spatial effects which have not needed consideration in earlier reactors but which in CAGR would need very careful evaluation.
Citation Formats
Telford, A. R.R.
Review of control rod calibration methods for irradiated AGRs.
United Kingdom: N. p.,
1975.
Web.
Telford, A. R.R.
Review of control rod calibration methods for irradiated AGRs.
United Kingdom.
Telford, A. R.R.
1975.
"Review of control rod calibration methods for irradiated AGRs."
United Kingdom.
@misc{etde_8188084,
title = {Review of control rod calibration methods for irradiated AGRs}
author = {Telford, A. R.R.}
abstractNote = {Methods of calibrating control rods with particular reference to irradiated CAGR are surveyed. Some systematic spatial effects are found and an estimate of their magnitude made. It is concluded that control rod oscillation provides a promising method of calibrating rods at power which is as yet untried on CAGR. Also the rod drop using inverse kinetics provides a rod calibration but spatial effects may be large and these would be difficult to correct theoretically. The pulsed neutron technique provides a calibration route with small errors due to spatial effects provided a suitable K-tube can be developed. The xenon transient method is shown to have spatial effects which have not needed consideration in earlier reactors but which in CAGR would need very careful evaluation.}
place = {United Kingdom}
year = {1975}
month = {Oct}
}
title = {Review of control rod calibration methods for irradiated AGRs}
author = {Telford, A. R.R.}
abstractNote = {Methods of calibrating control rods with particular reference to irradiated CAGR are surveyed. Some systematic spatial effects are found and an estimate of their magnitude made. It is concluded that control rod oscillation provides a promising method of calibrating rods at power which is as yet untried on CAGR. Also the rod drop using inverse kinetics provides a rod calibration but spatial effects may be large and these would be difficult to correct theoretically. The pulsed neutron technique provides a calibration route with small errors due to spatial effects provided a suitable K-tube can be developed. The xenon transient method is shown to have spatial effects which have not needed consideration in earlier reactors but which in CAGR would need very careful evaluation.}
place = {United Kingdom}
year = {1975}
month = {Oct}
}