You need JavaScript to view this

Correction for the absorption of plutonium alpha particles in filter paper used for dust sampling

Abstract

This sample of air-borne dust collected on a filter paper when laboratory air is monitored for plutonium with the 1195 portable dust sampling unit may be regarded, for counting purposes, as a thick source with a non-uniform distribution of alpha-active plutonium. Experiments have been carried out to determine a correction factor to be applied to the observed count on the filter paper sample to correct for internal absorption in the paper and on the dust layer. From the results obtained it is recommended that a correction factor of 2 be used.
Authors:
Publication Date:
Jan 01, 1956
Product Type:
Technical Report
Report Number:
AERE-HP/M-87
Reference Number:
ERA-10-047223; NTS-85-020653; EDB-85-158233
Resource Relation:
Other Information: Portions of this document are illegible in microfiche products
Subject:
54 ENVIRONMENTAL SCIENCES; ALPHA PARTICLES; ABSOLUTE COUNTING; CORRECTIONS; DUSTS; FILTERS; PLUTONIUM; ACTINIDES; CHARGED PARTICLES; COUNTING TECHNIQUES; ELEMENTS; METALS; TRANSURANIUM ELEMENTS; 500300* - Environment, Atmospheric- Radioactive Materials Monitoring & Transport- (-1989)
OSTI ID:
8116594
Research Organizations:
UKAEA Atomic Energy Research Establishment, Harwell
Country of Origin:
United Kingdom
Language:
English
Other Identifying Numbers:
Other: ON: DE85901936
Availability:
NTIS (US Sales Only), PC A02/MF A01; 1.
Submitting Site:
HEDB
Size:
Pages: 8
Announcement Date:
Oct 01, 1985

Citation Formats

Simons, J G. Correction for the absorption of plutonium alpha particles in filter paper used for dust sampling. United Kingdom: N. p., 1956. Web.
Simons, J G. Correction for the absorption of plutonium alpha particles in filter paper used for dust sampling. United Kingdom.
Simons, J G. 1956. "Correction for the absorption of plutonium alpha particles in filter paper used for dust sampling." United Kingdom.
@misc{etde_8116594,
title = {Correction for the absorption of plutonium alpha particles in filter paper used for dust sampling}
author = {Simons, J G}
abstractNote = {This sample of air-borne dust collected on a filter paper when laboratory air is monitored for plutonium with the 1195 portable dust sampling unit may be regarded, for counting purposes, as a thick source with a non-uniform distribution of alpha-active plutonium. Experiments have been carried out to determine a correction factor to be applied to the observed count on the filter paper sample to correct for internal absorption in the paper and on the dust layer. From the results obtained it is recommended that a correction factor of 2 be used.}
place = {United Kingdom}
year = {1956}
month = {Jan}
}