Abstract
The concept of a jet chamber for the central detector of OPAL has been tested with a full scale prototype. The design of this prototype, its mechanical and electrical structure and its support system for high voltage, gas, laser calibration and readout are described. The operating experience gathered since the summer of 1984 and the chamber performance as measured by its spatial resolution and ability to identify particles are also given.
Citation Formats
Fischer, H M, Hauschild, M, Hartmann, H, Hegerath, A, Boerner, H, Burckhart, H J, Dittmar, M, Hammarstreom, R, Heuer, R D, and Mazzone, L.
OPAL jet chamber full scale prototype.
Switzerland: N. p.,
1986.
Web.
Fischer, H M, Hauschild, M, Hartmann, H, Hegerath, A, Boerner, H, Burckhart, H J, Dittmar, M, Hammarstreom, R, Heuer, R D, & Mazzone, L.
OPAL jet chamber full scale prototype.
Switzerland.
Fischer, H M, Hauschild, M, Hartmann, H, Hegerath, A, Boerner, H, Burckhart, H J, Dittmar, M, Hammarstreom, R, Heuer, R D, and Mazzone, L.
1986.
"OPAL jet chamber full scale prototype."
Switzerland.
@misc{etde_7836386,
title = {OPAL jet chamber full scale prototype}
author = {Fischer, H M, Hauschild, M, Hartmann, H, Hegerath, A, Boerner, H, Burckhart, H J, Dittmar, M, Hammarstreom, R, Heuer, R D, and Mazzone, L}
abstractNote = {The concept of a jet chamber for the central detector of OPAL has been tested with a full scale prototype. The design of this prototype, its mechanical and electrical structure and its support system for high voltage, gas, laser calibration and readout are described. The operating experience gathered since the summer of 1984 and the chamber performance as measured by its spatial resolution and ability to identify particles are also given.}
place = {Switzerland}
year = {1986}
month = {May}
}
title = {OPAL jet chamber full scale prototype}
author = {Fischer, H M, Hauschild, M, Hartmann, H, Hegerath, A, Boerner, H, Burckhart, H J, Dittmar, M, Hammarstreom, R, Heuer, R D, and Mazzone, L}
abstractNote = {The concept of a jet chamber for the central detector of OPAL has been tested with a full scale prototype. The design of this prototype, its mechanical and electrical structure and its support system for high voltage, gas, laser calibration and readout are described. The operating experience gathered since the summer of 1984 and the chamber performance as measured by its spatial resolution and ability to identify particles are also given.}
place = {Switzerland}
year = {1986}
month = {May}
}