Abstract
The fundamental study of quantitative scale display of the organ uptake with ..gamma..-camera was performed in special respect of the thyroid gland and the pancreas. As one of the measurements on certain dimension of the organ, an optical progression outside the digital image was expressed, and was subjected to the quantitative scale with the use of the threshold level. And a rather satisfactory correlation was clinically obtained between the scale display and the thyroidal /sup 131/I uptake. For the purpose of revising the above scale display, the organ depth was measured with RI by the aid of the phantom. Then the pancreas depth determined by the count rate ratio curve of 140 and 270 keV peak of /sup 75/Se energies. However, the body background and the radioactive rays from the neighboring organs interfered with this curve.
Citation Formats
Ishigami, K, and Matsumoto, M.
A study of quantitative scale display of the organ uptake with gamma-camera.
Japan: N. p.,
1975.
Web.
Ishigami, K, & Matsumoto, M.
A study of quantitative scale display of the organ uptake with gamma-camera.
Japan.
Ishigami, K, and Matsumoto, M.
1975.
"A study of quantitative scale display of the organ uptake with gamma-camera."
Japan.
@misc{etde_7363199,
title = {A study of quantitative scale display of the organ uptake with gamma-camera}
author = {Ishigami, K, and Matsumoto, M}
abstractNote = {The fundamental study of quantitative scale display of the organ uptake with ..gamma..-camera was performed in special respect of the thyroid gland and the pancreas. As one of the measurements on certain dimension of the organ, an optical progression outside the digital image was expressed, and was subjected to the quantitative scale with the use of the threshold level. And a rather satisfactory correlation was clinically obtained between the scale display and the thyroidal /sup 131/I uptake. For the purpose of revising the above scale display, the organ depth was measured with RI by the aid of the phantom. Then the pancreas depth determined by the count rate ratio curve of 140 and 270 keV peak of /sup 75/Se energies. However, the body background and the radioactive rays from the neighboring organs interfered with this curve.}
journal = []
volume = {24:5}
journal type = {AC}
place = {Japan}
year = {1975}
month = {May}
}
title = {A study of quantitative scale display of the organ uptake with gamma-camera}
author = {Ishigami, K, and Matsumoto, M}
abstractNote = {The fundamental study of quantitative scale display of the organ uptake with ..gamma..-camera was performed in special respect of the thyroid gland and the pancreas. As one of the measurements on certain dimension of the organ, an optical progression outside the digital image was expressed, and was subjected to the quantitative scale with the use of the threshold level. And a rather satisfactory correlation was clinically obtained between the scale display and the thyroidal /sup 131/I uptake. For the purpose of revising the above scale display, the organ depth was measured with RI by the aid of the phantom. Then the pancreas depth determined by the count rate ratio curve of 140 and 270 keV peak of /sup 75/Se energies. However, the body background and the radioactive rays from the neighboring organs interfered with this curve.}
journal = []
volume = {24:5}
journal type = {AC}
place = {Japan}
year = {1975}
month = {May}
}