You need JavaScript to view this

Radiometric detection in flow-injection analysis; Radiometric flow-injection analysis

Abstract

A single line system with a detector of radioactivity was used for the determination of [sup 60]Co. In the determination, no additional chemistry is involved and limited dispersion is desirable. For this application, the FIA system is used only as a transport system for the sample up to the detector. (author) 7 refs.; 4 figs.
Authors:
Myint, U; Han, B; Myoe, K M; Kywe, A; Thida,; [1]  Toelgyessy, J [2] 
  1. Yangon Univ. (Myanmar). Dept. of Chemistry
  2. Slovak Technical Univ., Braatislava (Slovakia). Dept. of Environmental Science
Publication Date:
May 17, 1994
Product Type:
Journal Article
Reference Number:
AIX-25-048982; EDB-94-110645
Resource Relation:
Journal Name: Journal of Radioanalytical and Nuclear Chemistry; (Switzerland); Journal Volume: 187:2
Subject:
37 INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; COBALT 60; RADIOMETRIC ANALYSIS; FLUID FLOW; DISPERSION RELATIONS; FLOWSHEETS; INJECTION; RADIOACTIVITY TRANSPORT; TIME DEPENDENCE; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; CHEMICAL ANALYSIS; COBALT ISOTOPES; DIAGRAMS; INTAKE; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; MINUTES LIVING RADIOISOTOPES; NUCLEI; ODD-ODD NUCLEI; QUANTITATIVE CHEMICAL ANALYSIS; RADIOISOTOPES; YEARS LIVING RADIOISOT; 400101* - Activation, Nuclear Reaction, Radiometric & Radiochemical Procedures
OSTI ID:
7276147
Country of Origin:
Hungary
Language:
English
Other Identifying Numbers:
Journal ID: ISSN 0236-5731; CODEN: JRNCDM
Submitting Site:
INIS
Size:
Pages: 117-122
Announcement Date:
Aug 15, 1994

Citation Formats

Myint, U, Han, B, Myoe, K M, Kywe, A, Thida,, and Toelgyessy, J. Radiometric detection in flow-injection analysis; Radiometric flow-injection analysis. Hungary: N. p., 1994. Web. doi:10.1007/BF02162658.
Myint, U, Han, B, Myoe, K M, Kywe, A, Thida,, & Toelgyessy, J. Radiometric detection in flow-injection analysis; Radiometric flow-injection analysis. Hungary. https://doi.org/10.1007/BF02162658
Myint, U, Han, B, Myoe, K M, Kywe, A, Thida,, and Toelgyessy, J. 1994. "Radiometric detection in flow-injection analysis; Radiometric flow-injection analysis." Hungary. https://doi.org/10.1007/BF02162658.
@misc{etde_7276147,
title = {Radiometric detection in flow-injection analysis; Radiometric flow-injection analysis}
author = {Myint, U, Han, B, Myoe, K M, Kywe, A, Thida,, and Toelgyessy, J}
abstractNote = {A single line system with a detector of radioactivity was used for the determination of [sup 60]Co. In the determination, no additional chemistry is involved and limited dispersion is desirable. For this application, the FIA system is used only as a transport system for the sample up to the detector. (author) 7 refs.; 4 figs.}
doi = {10.1007/BF02162658}
journal = []
volume = {187:2}
journal type = {AC}
place = {Hungary}
year = {1994}
month = {May}
}