Abstract
Several techniques are discussed for velocity and energy spectrometry of relativistic heavy ions with good resolution. A foil telescope with chevron channel plate detectors is described. A test of this telescope was performed using 2.1 GeV/A C/sup 6 +/ ions, and a time-of-flight resolution of 160 ps was measured. Qualitative information on the effect of foil thickness was also obtained.
Gabor, G;
Schimmerling, W;
Greiner, D;
Bieser, F;
Lindstrom, P
[1]
- California Univ., Berkeley (USA). Lawrence Berkeley Lab.
Citation Formats
Gabor, G, Schimmerling, W, Greiner, D, Bieser, F, and Lindstrom, P.
High resolution spectrometry for relativistic heavy ions.
Netherlands: N. p.,
1975.
Web.
doi:10.1016/0029-554X(75)90158-5.
Gabor, G, Schimmerling, W, Greiner, D, Bieser, F, & Lindstrom, P.
High resolution spectrometry for relativistic heavy ions.
Netherlands.
https://doi.org/10.1016/0029-554X(75)90158-5
Gabor, G, Schimmerling, W, Greiner, D, Bieser, F, and Lindstrom, P.
1975.
"High resolution spectrometry for relativistic heavy ions."
Netherlands.
https://doi.org/10.1016/0029-554X(75)90158-5.
@misc{etde_7262083,
title = {High resolution spectrometry for relativistic heavy ions}
author = {Gabor, G, Schimmerling, W, Greiner, D, Bieser, F, and Lindstrom, P}
abstractNote = {Several techniques are discussed for velocity and energy spectrometry of relativistic heavy ions with good resolution. A foil telescope with chevron channel plate detectors is described. A test of this telescope was performed using 2.1 GeV/A C/sup 6 +/ ions, and a time-of-flight resolution of 160 ps was measured. Qualitative information on the effect of foil thickness was also obtained.}
doi = {10.1016/0029-554X(75)90158-5}
journal = []
volume = {130:1}
journal type = {AC}
place = {Netherlands}
year = {1975}
month = {Dec}
}
title = {High resolution spectrometry for relativistic heavy ions}
author = {Gabor, G, Schimmerling, W, Greiner, D, Bieser, F, and Lindstrom, P}
abstractNote = {Several techniques are discussed for velocity and energy spectrometry of relativistic heavy ions with good resolution. A foil telescope with chevron channel plate detectors is described. A test of this telescope was performed using 2.1 GeV/A C/sup 6 +/ ions, and a time-of-flight resolution of 160 ps was measured. Qualitative information on the effect of foil thickness was also obtained.}
doi = {10.1016/0029-554X(75)90158-5}
journal = []
volume = {130:1}
journal type = {AC}
place = {Netherlands}
year = {1975}
month = {Dec}
}