Forming of electron beams from a betatron by foils scatterers

Journal Article:

Abstract

The technique of forming electron beams by one scattering foil and one compensating foil is discussed. This method provides a means for producing large-size uniform dose distributions with much smaller losses in dose rate as compared with conventional beam forming by ine foil. Moreover, the energy losses involved in this process and the background of concomitant bremsstrahlung are much less. A techinque of calculation to determine approximate parameters of the compensating foils is described.
Authors:
Kozlov, A P; Shishov, V A [1] 
  1. N.N. Petrov Research Inst. of Oncology, Leningrad (USSR). Laboratory of High Energics
Publication Date:
Dec 01, 1976
Product Type:
Journal Article
Reference Number:
AIX-08-310851; EDB-77-101674
Resource Relation:
Journal Name: Acta Radiol., Ther., Phys., Biol.; (Sweden); Journal Volume: 15:6
Subject:
43 PARTICLE ACCELERATORS; BETATRONS; ELECTRON BEAMS; BEAM PRODUCTION; BEAM OPTICS; DISTRIBUTION; ENERGY LOSSES; FOILS; ACCELERATORS; BEAMS; CYCLIC ACCELERATORS; LEPTON BEAMS; PARTICLE BEAMS; 430303* - Particle Accelerators- Experimental Facilities & Equipment
OSTI ID:
7215479
Country of Origin:
Sweden
Language:
English
Other Identifying Numbers:
Journal ID: CODEN: ATHBA
Submitting Site:
INIS
Size:
Pages: 493-512
Announcement Date:
Jun 01, 1977

Journal Article:

Citation Formats

Kozlov, A P, and Shishov, V A. Forming of electron beams from a betatron by foils scatterers. Sweden: N. p., 1976. Web.
Kozlov, A P, & Shishov, V A. Forming of electron beams from a betatron by foils scatterers. Sweden.
Kozlov, A P, and Shishov, V A. 1976. "Forming of electron beams from a betatron by foils scatterers." Sweden.
@misc{etde_7215479,
title = {Forming of electron beams from a betatron by foils scatterers}
author = {Kozlov, A P, and Shishov, V A}
abstractNote = {The technique of forming electron beams by one scattering foil and one compensating foil is discussed. This method provides a means for producing large-size uniform dose distributions with much smaller losses in dose rate as compared with conventional beam forming by ine foil. Moreover, the energy losses involved in this process and the background of concomitant bremsstrahlung are much less. A techinque of calculation to determine approximate parameters of the compensating foils is described.}
journal = {Acta Radiol., Ther., Phys., Biol.; (Sweden)}
volume = {15:6}
journal type = {AC}
place = {Sweden}
year = {1976}
month = {Dec}
}