Parameters of image quality, comprising spacial resolution and contrast, have been determined in the form of a contrast/detail diagram for a digital system (Topogram) and a film-screen system. The digital system was particularly examined concerning its contrast sensitivity in relation to quantum noise. The clinical implications of the comparison of the systems, where evaluated on chest X-rays of 250 patients. Despite lower image sharpness, the digital method is already able to produce equivalent or better diagnostic results in certain circumstances. The advantages and disadvantages of both systems are discussed in detail.
Publication Date:
Jan 01, 1984
Product Type:
Journal Article
Reference Number:
EDB-84-095016
Resource Relation:
Journal Name: Fortschr. Geb. Roentgenstr. Nuklearmed.; (Germany, Federal Republic of); Journal Volume: 140:1; Other Information: With 6 figs
Subject:
62 RADIOLOGY AND NUCLEAR MEDICINE; BIOMEDICAL RADIOGRAPHY; DIGITAL SYSTEMS; CHEST; METASTASES; IMAGE PROCESSING; COMPARATIVE EVALUATIONS; DIAGNOSIS; IMAGE INTENSIFIERS; PATIENTS; PHOTOGRAPHIC FILMS; SPATIAL RESOLUTION; BODY; BODY AREAS; DIAGNOSTIC TECHNIQUES; MEDICINE; NUCLEAR MEDICINE; PROCESSING; RADIOLOGY; RESOLUTION; 550602* - Medicine- External Radiation in Diagnostics- (1980-)
OSTI ID:
7191192
Country of Origin:
Germany
Language:
German
Other Identifying Numbers:
Journal ID: CODEN: FGRNA
Submitting Site:
HEDB
Size:
Pages: 87-92
Announcement Date:

Journal Article:

Citation Formats

Kalender, W A, and Huebener, K H. Comparison of digital radiography and conventional film screen radiography. Germany: N. p., 1984. Web. doi:10.1055/s-2008-1052928.
Kalender, W A, & Huebener, K H. Comparison of digital radiography and conventional film screen radiography. Germany. doi:10.1055/s-2008-1052928.
Kalender, W A, and Huebener, K H. 1984. "Comparison of digital radiography and conventional film screen radiography." Germany. doi:10.1055/s-2008-1052928. https://www.osti.gov/servlets/purl/10.1055/s-2008-1052928.
@misc{etde_7191192,
title = {Comparison of digital radiography and conventional film screen radiography}
author = {Kalender, W A, and Huebener, K H}
abstractNote = {Parameters of image quality, comprising spacial resolution and contrast, have been determined in the form of a contrast/detail diagram for a digital system (Topogram) and a film-screen system. The digital system was particularly examined concerning its contrast sensitivity in relation to quantum noise. The clinical implications of the comparison of the systems, where evaluated on chest X-rays of 250 patients. Despite lower image sharpness, the digital method is already able to produce equivalent or better diagnostic results in certain circumstances. The advantages and disadvantages of both systems are discussed in detail.}
doi = {10.1055/s-2008-1052928}
journal = {Fortschr. Geb. Roentgenstr. Nuklearmed.; (Germany, Federal Republic of)}
volume = {140:1}
journal type = {AC}
place = {Germany}
year = {1984}
month = {Jan}
}