Abstract
Ageing and aggressive enviromental conditions of concrete structures will result in deterioration of concrete and corrosion of steel in concrete. Corrosion of steel will in time result in the end of the service life or expensive renovations, unless corrosion of steel is noticed and renovated in time. Corrosion of steel in concrete can be found out by the present corrosion measurement methods, so that renovation can be started in right time. The report presents mainly on the basis of the literature references the following corrosion measurement methods: polarisation resistance, AC-impedance, electrical resistance probe, electrochemical noice and half-cell potential mapping. The half-cell potential mapping will be presented more precisely than the other corrosion measurement methods, for the potential mapping is the most used method. Concrete and Soils Laboratory of Imatran Voima Oy uses in the measurement of reinforcement corrosion the English, eight channel potential measuring equipment.
Citation Formats
Meuronen, A.
Measurement of reinforcement corrosion in concrete structures. Betonirakenteiden raudoituksen korroosion tutkiminen.
Finland: N. p.,
1992.
Web.
Meuronen, A.
Measurement of reinforcement corrosion in concrete structures. Betonirakenteiden raudoituksen korroosion tutkiminen.
Finland.
Meuronen, A.
1992.
"Measurement of reinforcement corrosion in concrete structures. Betonirakenteiden raudoituksen korroosion tutkiminen."
Finland.
@misc{etde_7162339,
title = {Measurement of reinforcement corrosion in concrete structures. Betonirakenteiden raudoituksen korroosion tutkiminen}
author = {Meuronen, A}
abstractNote = {Ageing and aggressive enviromental conditions of concrete structures will result in deterioration of concrete and corrosion of steel in concrete. Corrosion of steel will in time result in the end of the service life or expensive renovations, unless corrosion of steel is noticed and renovated in time. Corrosion of steel in concrete can be found out by the present corrosion measurement methods, so that renovation can be started in right time. The report presents mainly on the basis of the literature references the following corrosion measurement methods: polarisation resistance, AC-impedance, electrical resistance probe, electrochemical noice and half-cell potential mapping. The half-cell potential mapping will be presented more precisely than the other corrosion measurement methods, for the potential mapping is the most used method. Concrete and Soils Laboratory of Imatran Voima Oy uses in the measurement of reinforcement corrosion the English, eight channel potential measuring equipment.}
place = {Finland}
year = {1992}
month = {Mar}
}
title = {Measurement of reinforcement corrosion in concrete structures. Betonirakenteiden raudoituksen korroosion tutkiminen}
author = {Meuronen, A}
abstractNote = {Ageing and aggressive enviromental conditions of concrete structures will result in deterioration of concrete and corrosion of steel in concrete. Corrosion of steel will in time result in the end of the service life or expensive renovations, unless corrosion of steel is noticed and renovated in time. Corrosion of steel in concrete can be found out by the present corrosion measurement methods, so that renovation can be started in right time. The report presents mainly on the basis of the literature references the following corrosion measurement methods: polarisation resistance, AC-impedance, electrical resistance probe, electrochemical noice and half-cell potential mapping. The half-cell potential mapping will be presented more precisely than the other corrosion measurement methods, for the potential mapping is the most used method. Concrete and Soils Laboratory of Imatran Voima Oy uses in the measurement of reinforcement corrosion the English, eight channel potential measuring equipment.}
place = {Finland}
year = {1992}
month = {Mar}
}