Radiometric flow injection analysis with an ASIA (Ismatec) analyzer

Abstract

Radiometric Flow Injection Analysis of a radioactive ([sup 131]I) sample is described. For analysis an ASIA (Ismatec) analyzer with a NaI(Tl) scintillation detector was used. (author) 5 refs.; 3 figs.
Authors:
Myint, U; Win, N; San, K; Han, B; Myoe, K M; [1]  Toelgyessy, J [2] 
  1. Yangon Univ. (Myanmar). Dept. of Chemistry
  2. Slovak Technical Univ., Bratislava (Slovakia). Dept. of Environmental Science
Publication Date:
Jul 01, 1994
Product Type:
Journal Article
Reference Number:
AIX-25-068904; EDB-94-153174
Resource Relation:
Journal Name: Journal of Radioanalytical and Nuclear Chemistry; (Switzerland); Journal Volume: 187:5
Subject:
37 INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; IODINE 131; RADIOMETRIC ANALYSIS; INJECTION; AUTOMATION; DIAGRAMS; FLUID FLOW; NAI DETECTORS; TIME DEPENDENCE; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; CHEMICAL ANALYSIS; DAYS LIVING RADIOISOTOPES; INTAKE; INTERMEDIATE MASS NUCLEI; IODINE ISOTOPES; ISOTOPES; MEASURING INSTRUMENTS; NUCLEI; ODD-EVEN NUCLEI; QUANTITATIVE CHEMICAL ANALYSIS; RADIATION DETECTORS; RADIOISOTOPES; SCINTILLATION COUNTERS; SOLID SCINTILLATION DETECTORS; 400101* - Activation, Nuclear Reaction, Radiometric & Radiochemical Procedures
OSTI ID:
7151964
Country of Origin:
Hungary
Language:
English
Other Identifying Numbers:
Journal ID: ISSN 0236-5731; CODEN: JRNCDM
Submitting Site:
INIS
Size:
Pages: 345-349
Announcement Date:
Nov 15, 1994

Citation Formats

Myint, U, Win, N, San, K, Han, B, Myoe, K M, and Toelgyessy, J. Radiometric flow injection analysis with an ASIA (Ismatec) analyzer. Hungary: N. p., 1994. Web. doi:10.1007/BF02163598.
Myint, U, Win, N, San, K, Han, B, Myoe, K M, & Toelgyessy, J. Radiometric flow injection analysis with an ASIA (Ismatec) analyzer. Hungary. https://doi.org/10.1007/BF02163598
Myint, U, Win, N, San, K, Han, B, Myoe, K M, and Toelgyessy, J. 1994. "Radiometric flow injection analysis with an ASIA (Ismatec) analyzer." Hungary. https://doi.org/10.1007/BF02163598.
@misc{etde_7151964,
title = {Radiometric flow injection analysis with an ASIA (Ismatec) analyzer}
author = {Myint, U, Win, N, San, K, Han, B, Myoe, K M, and Toelgyessy, J}
abstractNote = {Radiometric Flow Injection Analysis of a radioactive ([sup 131]I) sample is described. For analysis an ASIA (Ismatec) analyzer with a NaI(Tl) scintillation detector was used. (author) 5 refs.; 3 figs.}
doi = {10.1007/BF02163598}
journal = []
volume = {187:5}
journal type = {AC}
place = {Hungary}
year = {1994}
month = {Jul}
}