Abstract
Units Nos. 1 and 2 of Kawagoe Power Station, Chubu Electric Power Co., Inc. are the first modern Ultra Supercritical pressure units with the steam conditions of 316 kgf/cm2g, 566/566/566 deg C. The No. 1 unit has commenced commercial operation in June 1989. Although the advanced steam conditions are adopted, the required capabilities for the latest designed utility boilers in Japan-DSS operation, high load change rate, FCB operation and so on-are also taken into consideration. Therefore a lot of improved technology and materials are adopted for the design of these steam generators.
Citation Formats
Kawamura, T, Haneda, H, Toyoda, T, Sada, T, and Araoka, M.
Design of LNG-fired USC steam generator for units Nos. 1 and 2 of Kawagoe Power Station, Chubu Electric Power Co. , Inc. Technical bulletin.
Japan: N. p.,
1989.
Web.
Kawamura, T, Haneda, H, Toyoda, T, Sada, T, & Araoka, M.
Design of LNG-fired USC steam generator for units Nos. 1 and 2 of Kawagoe Power Station, Chubu Electric Power Co. , Inc. Technical bulletin.
Japan.
Kawamura, T, Haneda, H, Toyoda, T, Sada, T, and Araoka, M.
1989.
"Design of LNG-fired USC steam generator for units Nos. 1 and 2 of Kawagoe Power Station, Chubu Electric Power Co. , Inc. Technical bulletin."
Japan.
@misc{etde_7126848,
title = {Design of LNG-fired USC steam generator for units Nos. 1 and 2 of Kawagoe Power Station, Chubu Electric Power Co. , Inc. Technical bulletin}
author = {Kawamura, T, Haneda, H, Toyoda, T, Sada, T, and Araoka, M}
abstractNote = {Units Nos. 1 and 2 of Kawagoe Power Station, Chubu Electric Power Co., Inc. are the first modern Ultra Supercritical pressure units with the steam conditions of 316 kgf/cm2g, 566/566/566 deg C. The No. 1 unit has commenced commercial operation in June 1989. Although the advanced steam conditions are adopted, the required capabilities for the latest designed utility boilers in Japan-DSS operation, high load change rate, FCB operation and so on-are also taken into consideration. Therefore a lot of improved technology and materials are adopted for the design of these steam generators.}
place = {Japan}
year = {1989}
month = {Jan}
}
title = {Design of LNG-fired USC steam generator for units Nos. 1 and 2 of Kawagoe Power Station, Chubu Electric Power Co. , Inc. Technical bulletin}
author = {Kawamura, T, Haneda, H, Toyoda, T, Sada, T, and Araoka, M}
abstractNote = {Units Nos. 1 and 2 of Kawagoe Power Station, Chubu Electric Power Co., Inc. are the first modern Ultra Supercritical pressure units with the steam conditions of 316 kgf/cm2g, 566/566/566 deg C. The No. 1 unit has commenced commercial operation in June 1989. Although the advanced steam conditions are adopted, the required capabilities for the latest designed utility boilers in Japan-DSS operation, high load change rate, FCB operation and so on-are also taken into consideration. Therefore a lot of improved technology and materials are adopted for the design of these steam generators.}
place = {Japan}
year = {1989}
month = {Jan}
}