Abstract
The concept of a jet chamber for the central detector of OPAL was tested with a full scale prototype. The design of this prototype, its mechanical and electrical structure and its support system for high voltage, gas, laser calibration, and readout are described. Operating experience was gathered since summer 1984. The chamber performance in terms of spatial resolution and particle identification capability is given.
Citation Formats
Fischer, H M, Hauschild, M, Hartmann, H, Hegerath, A, Boerner, H, Burckhart, H J, Dittmar, M, Hammarstroem, R, Heuer, R D, and Mazzone, L.
OPAL jet chamber full-scale prototype.
Netherlands: N. p.,
1986.
Web.
Fischer, H M, Hauschild, M, Hartmann, H, Hegerath, A, Boerner, H, Burckhart, H J, Dittmar, M, Hammarstroem, R, Heuer, R D, & Mazzone, L.
OPAL jet chamber full-scale prototype.
Netherlands.
Fischer, H M, Hauschild, M, Hartmann, H, Hegerath, A, Boerner, H, Burckhart, H J, Dittmar, M, Hammarstroem, R, Heuer, R D, and Mazzone, L.
1986.
"OPAL jet chamber full-scale prototype."
Netherlands.
@misc{etde_7069329,
title = {OPAL jet chamber full-scale prototype}
author = {Fischer, H M, Hauschild, M, Hartmann, H, Hegerath, A, Boerner, H, Burckhart, H J, Dittmar, M, Hammarstroem, R, Heuer, R D, and Mazzone, L}
abstractNote = {The concept of a jet chamber for the central detector of OPAL was tested with a full scale prototype. The design of this prototype, its mechanical and electrical structure and its support system for high voltage, gas, laser calibration, and readout are described. Operating experience was gathered since summer 1984. The chamber performance in terms of spatial resolution and particle identification capability is given.}
journal = []
volume = {252:2/3}
place = {Netherlands}
year = {1986}
month = {Dec}
}
title = {OPAL jet chamber full-scale prototype}
author = {Fischer, H M, Hauschild, M, Hartmann, H, Hegerath, A, Boerner, H, Burckhart, H J, Dittmar, M, Hammarstroem, R, Heuer, R D, and Mazzone, L}
abstractNote = {The concept of a jet chamber for the central detector of OPAL was tested with a full scale prototype. The design of this prototype, its mechanical and electrical structure and its support system for high voltage, gas, laser calibration, and readout are described. Operating experience was gathered since summer 1984. The chamber performance in terms of spatial resolution and particle identification capability is given.}
journal = []
volume = {252:2/3}
place = {Netherlands}
year = {1986}
month = {Dec}
}