You need JavaScript to view this

XERG-mammography system: a solution to the dose-quality problem

Abstract

The XERG (Xonics-Electron-Radio-Graphy) system is the first ionographic system (High-Pressure-Gas-Iono-graphy) suitable for clinical application which became available for testing. The basic principle, the function and imaging qualities of the XERG system are described and first clinical experiences reported. The XERG mammogram is a transparent X-ray negative image, the image quality of which is characterized by good general image contrast, a moderate edge-effect and a high quantum-noise level but giving an extremely low dose rate (4.5% compared to screenless mammography film). Although the XERG quality is not satisfactory in contact technique, it yields results which are equal in quality, when using a 1.5-fold magnification technique, to the results obtained with screenless film mammography at one-tenth of the dose, and is superior to any commercially available film-screen system. Hence, in our opinion, the XERG mammography system is a step forward towards high-quality low-dose mammography.
Authors:
Publication Date:
May 01, 1981
Product Type:
Journal Article
Reference Number:
EDB-82-166119
Resource Relation:
Journal Name: Eur. J. Radiol.; (Germany, Federal Republic of); Journal Volume: 1:2
Subject:
62 RADIOLOGY AND NUCLEAR MEDICINE; 47 OTHER INSTRUMENTATION; BIOMEDICAL RADIOGRAPHY; EFFICIENCY; COMPARATIVE EVALUATIONS; FEMALES; FREONS; IMAGES; PATIENTS; PERFORMANCE; PHOTOGRAPHIC FILMS; RADIATION DOSES; DIAGNOSTIC TECHNIQUES; DOSES; HALOGENATED ALIPHATIC HYDROCARBONS; MEDICINE; NUCLEAR MEDICINE; ORGANIC COMPOUNDS; ORGANIC HALOGEN COMPOUNDS; RADIOLOGY; 550602* - Medicine- External Radiation in Diagnostics- (1980-); 440300 - Miscellaneous Instruments- (-1989)
OSTI ID:
6843591
Research Organizations:
Klinik fuer Radiologie, Nuklearmedizin und Physikalische Therapie, Klinikum Steglitz, Free University of Berlin
Country of Origin:
Germany
Language:
English
Other Identifying Numbers:
Journal ID: CODEN: EJRAD
Submitting Site:
HEDB
Size:
Pages: 143-151
Announcement Date:
Aug 01, 1982

Citation Formats

Friedrich, M. XERG-mammography system: a solution to the dose-quality problem. Germany: N. p., 1981. Web.
Friedrich, M. XERG-mammography system: a solution to the dose-quality problem. Germany.
Friedrich, M. 1981. "XERG-mammography system: a solution to the dose-quality problem." Germany.
@misc{etde_6843591,
title = {XERG-mammography system: a solution to the dose-quality problem}
author = {Friedrich, M}
abstractNote = {The XERG (Xonics-Electron-Radio-Graphy) system is the first ionographic system (High-Pressure-Gas-Iono-graphy) suitable for clinical application which became available for testing. The basic principle, the function and imaging qualities of the XERG system are described and first clinical experiences reported. The XERG mammogram is a transparent X-ray negative image, the image quality of which is characterized by good general image contrast, a moderate edge-effect and a high quantum-noise level but giving an extremely low dose rate (4.5% compared to screenless mammography film). Although the XERG quality is not satisfactory in contact technique, it yields results which are equal in quality, when using a 1.5-fold magnification technique, to the results obtained with screenless film mammography at one-tenth of the dose, and is superior to any commercially available film-screen system. Hence, in our opinion, the XERG mammography system is a step forward towards high-quality low-dose mammography.}
journal = []
volume = {1:2}
journal type = {AC}
place = {Germany}
year = {1981}
month = {May}
}