Intrinsically safe electrical installations, auxiliary circuits and electric communication equipment

Journal Article:

Abstract

Technical progress has not stopped short of electrical systems in mining, so that three new chapters are new included in the VDE regulations leaflet No. 0118 on 'Installation of electrical systems in underground coal mining'. The regulations on intrinsically safe electric systems, auxiliary circuits and communication systems are briefly described, and grounds for the regulations are presented. The regulations already take account of European regulations on intrinsic safety which will soon be published in a European Regulation on Mine Explosions. In the chapters on auxiliary circuits and communication systems, protection against direct contact, fires, and explosions is discussed as well as the further goal of reliable signal transmission.
Authors:
Publication Date:
Nov 19, 1981
Product Type:
Journal Article
Reference Number:
EDB-82-168377
Resource Relation:
Journal Name: Glueckauf; (Germany, Federal Republic of); Journal Volume: 117:22
Subject:
01 COAL, LIGNITE, AND PEAT; 42 ENGINEERING; ELECTRICAL EQUIPMENT; STANDARDS; UNDERGROUND MINING; COAL MINES; CONTROL EQUIPMENT; FIRE PREVENTION; REMOTE CONTROL; CONTROL; EQUIPMENT; MINES; MINING; UNDERGROUND FACILITIES; 012000* - Coal, Lignite, & Peat- Mining; 420206 - Engineering- Mining & Drilling Equipment & Facilities- (1980-1989)
OSTI ID:
6836164
Country of Origin:
Germany
Language:
German
Other Identifying Numbers:
Journal ID: CODEN: GLUEA
Submitting Site:
HEDB
Size:
Pages: 1484-1488
Announcement Date:
Aug 01, 1982

Journal Article:

Citation Formats

Herms, C D. Intrinsically safe electrical installations, auxiliary circuits and electric communication equipment. Germany: N. p., 1981. Web.
Herms, C D. Intrinsically safe electrical installations, auxiliary circuits and electric communication equipment. Germany.
Herms, C D. 1981. "Intrinsically safe electrical installations, auxiliary circuits and electric communication equipment." Germany.
@misc{etde_6836164,
title = {Intrinsically safe electrical installations, auxiliary circuits and electric communication equipment}
author = {Herms, C D}
abstractNote = {Technical progress has not stopped short of electrical systems in mining, so that three new chapters are new included in the VDE regulations leaflet No. 0118 on 'Installation of electrical systems in underground coal mining'. The regulations on intrinsically safe electric systems, auxiliary circuits and communication systems are briefly described, and grounds for the regulations are presented. The regulations already take account of European regulations on intrinsic safety which will soon be published in a European Regulation on Mine Explosions. In the chapters on auxiliary circuits and communication systems, protection against direct contact, fires, and explosions is discussed as well as the further goal of reliable signal transmission.}
journal = {Glueckauf; (Germany, Federal Republic of)}
volume = {117:22}
journal type = {AC}
place = {Germany}
year = {1981}
month = {Nov}
}