You need JavaScript to view this

Quality assurance in electrical engineering. VDE Regional Group Frankfurt am Main, workshop from November 2-23, 1987. Qualitaetssicherung in der elektrischen Energietechnik. VDE-Bezirksverein Frankfurt am Main, Arbeitsgemeinschaft vom 2. 11. bis 23. 11. 1987

Abstract

Quality assurance measures are explained at the example of an energy distributor. The VDE (German Association of Electrical Engineers) work team addresses the following articles on quality assurance to experts of energy techniques and those interested in this field. In detail, following topics are dealt with: Basic thoughts and principles of quality assurance; Quality assurance done by the producer, shown at the example of a medium-voltage power switch. Quality assurance done by the producer, shown at the example of a low-voltage power switch. Quality assurance done by the producer of electric distributing hands, shown at the example of a medium-voltage distributing band. Quality assurance by the producer of electric distributing boards, shown at the example of a low-voltage board. Quality assurance by means of maintenance measures in the electric system technique of a public utility. Quality assurance of electric systems and operational means of a public utility. Quality assurance by the operator of electric systems, shown at the example of an industrial plant. (HAG).
Authors:
Forst, H J [1] 
  1. ed.
Publication Date:
Jan 01, 1987
Product Type:
Book
Reference Number:
DE-88-012578; EDB-88-177138
Subject:
24 POWER TRANSMISSION AND DISTRIBUTION; 42 ENGINEERING; ELECTRICAL ENGINEERING; QUALITY ASSURANCE; ELECTRICAL EQUIPMENT; COST; DATA PROCESSING; DIAGRAMS; ECONOMICS; ELECTRIC CONTROLLERS; ELECTRIC POWER; FLOWSHEETS; MAINTENANCE; RELIABILITY; SAFETY ENGINEERING; SERVICE LIFE; TESTING; CONTROL EQUIPMENT; ENGINEERING; EQUIPMENT; POWER; PROCESSING; 200300* - Electric Power Engineering- Power Transmission & Distribution- (-1989); 420000 - Engineering
OSTI ID:
6781690
Country of Origin:
Germany
Language:
German
Submitting Site:
DE
Size:
Pages: 157
Announcement Date:
May 13, 2001

Citation Formats

Forst, H J. Quality assurance in electrical engineering. VDE Regional Group Frankfurt am Main, workshop from November 2-23, 1987. Qualitaetssicherung in der elektrischen Energietechnik. VDE-Bezirksverein Frankfurt am Main, Arbeitsgemeinschaft vom 2. 11. bis 23. 11. 1987. Germany: N. p., 1987. Web.
Forst, H J. Quality assurance in electrical engineering. VDE Regional Group Frankfurt am Main, workshop from November 2-23, 1987. Qualitaetssicherung in der elektrischen Energietechnik. VDE-Bezirksverein Frankfurt am Main, Arbeitsgemeinschaft vom 2. 11. bis 23. 11. 1987. Germany.
Forst, H J. 1987. "Quality assurance in electrical engineering. VDE Regional Group Frankfurt am Main, workshop from November 2-23, 1987. Qualitaetssicherung in der elektrischen Energietechnik. VDE-Bezirksverein Frankfurt am Main, Arbeitsgemeinschaft vom 2. 11. bis 23. 11. 1987." Germany.
@misc{etde_6781690,
title = {Quality assurance in electrical engineering. VDE Regional Group Frankfurt am Main, workshop from November 2-23, 1987. Qualitaetssicherung in der elektrischen Energietechnik. VDE-Bezirksverein Frankfurt am Main, Arbeitsgemeinschaft vom 2. 11. bis 23. 11. 1987}
author = {Forst, H J}
abstractNote = {Quality assurance measures are explained at the example of an energy distributor. The VDE (German Association of Electrical Engineers) work team addresses the following articles on quality assurance to experts of energy techniques and those interested in this field. In detail, following topics are dealt with: Basic thoughts and principles of quality assurance; Quality assurance done by the producer, shown at the example of a medium-voltage power switch. Quality assurance done by the producer, shown at the example of a low-voltage power switch. Quality assurance done by the producer of electric distributing hands, shown at the example of a medium-voltage distributing band. Quality assurance by the producer of electric distributing boards, shown at the example of a low-voltage board. Quality assurance by means of maintenance measures in the electric system technique of a public utility. Quality assurance of electric systems and operational means of a public utility. Quality assurance by the operator of electric systems, shown at the example of an industrial plant. (HAG).}
place = {Germany}
year = {1987}
month = {Jan}
}