Abstract
This report gives the results of an investigation into the relative merits of the systems: benzoic-salicylic acid, terephthalic-2-hydroxyterephthalic acid, the more recent ferrous sulphate-benzoic acid-xylenol orange (FBX), and the standard Fricke dosimeter, for the measurement of absorbed doses under identical irradiation conditions, in the range 10 to 1000 rads.
Matthews, R W;
[1]
Barker, N T;
Sangster, D F
- Australian Atomic Energy Commission Research Establishment, Lucas Heights
Citation Formats
Matthews, R W, Barker, N T, and Sangster, D F.
Comparison of some aqueous chemical dosimeters for absorbed doses of less than 1000 rads. [Benzoic--salicylic acid, terephtalic--2-hydroxyterephtabe acid, ferrous sulfate--benzoic acid--xylenol orange, and standard Fricke dosimeter].
United Kingdom: N. p.,
1978.
Web.
doi:10.1016/0020-708X(78)90150-3.
Matthews, R W, Barker, N T, & Sangster, D F.
Comparison of some aqueous chemical dosimeters for absorbed doses of less than 1000 rads. [Benzoic--salicylic acid, terephtalic--2-hydroxyterephtabe acid, ferrous sulfate--benzoic acid--xylenol orange, and standard Fricke dosimeter].
United Kingdom.
https://doi.org/10.1016/0020-708X(78)90150-3
Matthews, R W, Barker, N T, and Sangster, D F.
1978.
"Comparison of some aqueous chemical dosimeters for absorbed doses of less than 1000 rads. [Benzoic--salicylic acid, terephtalic--2-hydroxyterephtabe acid, ferrous sulfate--benzoic acid--xylenol orange, and standard Fricke dosimeter]."
United Kingdom.
https://doi.org/10.1016/0020-708X(78)90150-3.
@misc{etde_6757956,
title = {Comparison of some aqueous chemical dosimeters for absorbed doses of less than 1000 rads. [Benzoic--salicylic acid, terephtalic--2-hydroxyterephtabe acid, ferrous sulfate--benzoic acid--xylenol orange, and standard Fricke dosimeter]}
author = {Matthews, R W, Barker, N T, and Sangster, D F}
abstractNote = {This report gives the results of an investigation into the relative merits of the systems: benzoic-salicylic acid, terephthalic-2-hydroxyterephthalic acid, the more recent ferrous sulphate-benzoic acid-xylenol orange (FBX), and the standard Fricke dosimeter, for the measurement of absorbed doses under identical irradiation conditions, in the range 10 to 1000 rads.}
doi = {10.1016/0020-708X(78)90150-3}
journal = []
volume = {29:1}
journal type = {AC}
place = {United Kingdom}
year = {1978}
month = {Jan}
}
title = {Comparison of some aqueous chemical dosimeters for absorbed doses of less than 1000 rads. [Benzoic--salicylic acid, terephtalic--2-hydroxyterephtabe acid, ferrous sulfate--benzoic acid--xylenol orange, and standard Fricke dosimeter]}
author = {Matthews, R W, Barker, N T, and Sangster, D F}
abstractNote = {This report gives the results of an investigation into the relative merits of the systems: benzoic-salicylic acid, terephthalic-2-hydroxyterephthalic acid, the more recent ferrous sulphate-benzoic acid-xylenol orange (FBX), and the standard Fricke dosimeter, for the measurement of absorbed doses under identical irradiation conditions, in the range 10 to 1000 rads.}
doi = {10.1016/0020-708X(78)90150-3}
journal = []
volume = {29:1}
journal type = {AC}
place = {United Kingdom}
year = {1978}
month = {Jan}
}