Abstract
An attachment to MJ-1305 mass-spectrometer for ion ejection enabling to study interaction of ions and substance is designed. The attachment is accomodated with a block of diaphragms forming a beam of primary ions. A magneto-discharge pump has been used to improve vacuum in a sample chamber up to 5x10/sup -8/ torr. An universal exit slit permits producing ion beam currents ranging from 10/sup -9/ to 10/sup -10/ A with 4 keV energy under operating conditions of the spectrometer as an ion source. To ensure a higher noise stability of the measuring circuit the ion current is measured through a variable signal with synchronous detection employed.
Citation Formats
Kornyushkin, YW D, and Stavrovich, N V.
Mechanism of ion output for the MI-1305 mass-spectrometer.
USSR: N. p.,
1976.
Web.
Kornyushkin, YW D, & Stavrovich, N V.
Mechanism of ion output for the MI-1305 mass-spectrometer.
USSR.
Kornyushkin, YW D, and Stavrovich, N V.
1976.
"Mechanism of ion output for the MI-1305 mass-spectrometer."
USSR.
@misc{etde_6744534,
title = {Mechanism of ion output for the MI-1305 mass-spectrometer}
author = {Kornyushkin, YW D, and Stavrovich, N V}
abstractNote = {An attachment to MJ-1305 mass-spectrometer for ion ejection enabling to study interaction of ions and substance is designed. The attachment is accomodated with a block of diaphragms forming a beam of primary ions. A magneto-discharge pump has been used to improve vacuum in a sample chamber up to 5x10/sup -8/ torr. An universal exit slit permits producing ion beam currents ranging from 10/sup -9/ to 10/sup -10/ A with 4 keV energy under operating conditions of the spectrometer as an ion source. To ensure a higher noise stability of the measuring circuit the ion current is measured through a variable signal with synchronous detection employed.}
journal = []
volume = {5}
journal type = {AC}
place = {USSR}
year = {1976}
month = {Jan}
}
title = {Mechanism of ion output for the MI-1305 mass-spectrometer}
author = {Kornyushkin, YW D, and Stavrovich, N V}
abstractNote = {An attachment to MJ-1305 mass-spectrometer for ion ejection enabling to study interaction of ions and substance is designed. The attachment is accomodated with a block of diaphragms forming a beam of primary ions. A magneto-discharge pump has been used to improve vacuum in a sample chamber up to 5x10/sup -8/ torr. An universal exit slit permits producing ion beam currents ranging from 10/sup -9/ to 10/sup -10/ A with 4 keV energy under operating conditions of the spectrometer as an ion source. To ensure a higher noise stability of the measuring circuit the ion current is measured through a variable signal with synchronous detection employed.}
journal = []
volume = {5}
journal type = {AC}
place = {USSR}
year = {1976}
month = {Jan}
}