Considering environmental protection, the recent tendency has been to give up chlorination of cooling water for power stations. The experimental results show that cooling sea-water without chlorination cannot get rid of barnacles which grow inside condenser tubes when the speed of the cooling water is less than 1 m/s. Cleaning by sponge balls 2 -- 3 times a week is found to be effective for both barnacle prevention and inactive film formation on the tube surface.
Authors:
Mimura, K; Minamoto, K; Kyohara, S [1] 
  1. Kobe Steel Ltd. (Japan)
Publication Date:
Jul 01, 1977
Product Type:
Journal Article
Reference Number:
AIX-09-386609; ERA-03-052710; EDB-78-108574
Resource Relation:
Journal Name: R and D, Kobe Seiko Giho; (Japan); Journal Volume: 27:3
Subject:
22 GENERAL STUDIES OF NUCLEAR REACTORS; NUCLEAR POWER PLANTS; STEAM CONDENSERS; CLEANING; ALUMINIUM ALLOYS; FLOW RATE; IRON HYDROXIDES; MOLLUSCS; SEAWATER; SIMULATION; TITANIUM; TUBES; ALLOYS; ANIMALS; AQUATIC ORGANISMS; CONDENSERS; ELEMENTS; HYDROGEN COMPOUNDS; HYDROXIDES; INVERTEBRATES; IRON COMPOUNDS; METALS; NUCLEAR FACILITIES; OXYGEN COMPOUNDS; POWER PLANTS; THERMAL POWER PLANTS; TRANSITION ELEMENT COMPOUNDS; TRANSITION ELEMENTS; VAPOR CONDENSERS; WATER; 220200* - Nuclear Reactor Technology- Components & Accessories
OSTI ID:
6741734
Country of Origin:
Japan
Language:
Japanese
Other Identifying Numbers:
Journal ID: CODEN: RDKSB
Submitting Site:
INIS
Size:
Pages: 68-71
Announcement Date:
Jul 01, 1978

Citation Formats

Mimura, K, Minamoto, K, and Kyohara, S. Effect of sponge ball cleaning on removing barnacles in condenser tubes. Japan: N. p., 1977. Web.
Mimura, K, Minamoto, K, & Kyohara, S. Effect of sponge ball cleaning on removing barnacles in condenser tubes. Japan.
Mimura, K, Minamoto, K, and Kyohara, S. 1977. "Effect of sponge ball cleaning on removing barnacles in condenser tubes." Japan.
@misc{etde_6741734,
title = {Effect of sponge ball cleaning on removing barnacles in condenser tubes}
author = {Mimura, K, Minamoto, K, and Kyohara, S}
abstractNote = {Considering environmental protection, the recent tendency has been to give up chlorination of cooling water for power stations. The experimental results show that cooling sea-water without chlorination cannot get rid of barnacles which grow inside condenser tubes when the speed of the cooling water is less than 1 m/s. Cleaning by sponge balls 2 -- 3 times a week is found to be effective for both barnacle prevention and inactive film formation on the tube surface.}
journal = []
volume = {27:3}
journal type = {AC}
place = {Japan}
year = {1977}
month = {Jul}
}