You need JavaScript to view this

Production of sestamibi kit for nuclear imaging

Abstract

One of the research projects undertaken during the implementation of the IAEA Technical Assistance Cooperation Program in our department was inhouse production of sestamibi (MIBI) kit to be labelled with Tc99m pertechnetate for myocardial studies and for malignant tumor imaging. 100 mg raw materials of sestamibi was supplied by IAEA and the kit was prepared based on Janoki recipe. Using 6 mg MIBI, 192 mg glycine, 3.6 mg stannous chloride, 62.4 mg Na sub 4 Po sub 4 and 24 mg cysteine we have prepared 24 vials of MIBI kit under sterile condition and stored in the freezer at -70 degree C. The sterility of the kit was confirmed by microbiological test using cultured method. The stability test was done by labelling the kit with Tc-99m pertechnetate at day 1, 3, 7, 30 and 60 days after kit preparation. Using two system butanone and saline with ITLC the labelling efficiency of Tc-99m (MIBI) was found to be more than 90% in each case. The labelling efficiency was found to maintain at 90% up to 24 hours post reconstitution at room temperature. Biodistribution study was carried out by administering Tc-99m (MIBI) to mice intravenously at the dosage of IOO {mu} Ci  More>>
Authors:
Abdullah, Hakim; Zakaria, Ahmad; Yaacob, Hadzri; Ramli, Jamaluddin [1] 
  1. Universiti Sains Malaysia, Kelantan (Malaysia). School of Medical Sciences
Publication Date:
Dec 01, 1997
Product Type:
Conference
Report Number:
INIS-MY-010; CONF-9710240-
Reference Number:
SCA: 400703; PA: AIX-29:041550; EDB-98:083642; SN: 98001990372
Resource Relation:
Conference: INC `97: international nuclear conference: a new era in nuclear science and technology - the challenge of the 21st century, Kuala Lumpur (Malaysia), 27-28 Oct 1997; Other Information: PBD: Dec 1997; Related Information: Is Part Of Proceedings of INC `97 - International Nuclear Conference: a new era in Nuclear Science and Technology - the challenge of the 21st century; PB: 465 p.
Subject:
40 CHEMISTRY; CHEMICAL PREPARATION; LABELLED COMPOUNDS; NUCLEAR MEDICINE; RADIOCARDIOGRAPHY; RADIOISOTOPE SCANNING; TECHNETIUM 99
OSTI ID:
662149
Research Organizations:
Malaysian Inst. for Nuclear Technology Research (MINT), Bangi, Selangor (Malaysia); National Univ. of Malaysia, Bangi, Selangor (Malaysia); Malaysian Nuclear Society (Malaysia); American Nuclear Society (United States)
Country of Origin:
Malaysia
Language:
English
Other Identifying Numbers:
Other: ON: DE98630297; TRN: MY9800976041550
Availability:
INIS; OSTI as DE98630297
Submitting Site:
INIS
Size:
pp. 153-159
Announcement Date:
Aug 31, 1998

Citation Formats

Abdullah, Hakim, Zakaria, Ahmad, Yaacob, Hadzri, and Ramli, Jamaluddin. Production of sestamibi kit for nuclear imaging. Malaysia: N. p., 1997. Web.
Abdullah, Hakim, Zakaria, Ahmad, Yaacob, Hadzri, & Ramli, Jamaluddin. Production of sestamibi kit for nuclear imaging. Malaysia.
Abdullah, Hakim, Zakaria, Ahmad, Yaacob, Hadzri, and Ramli, Jamaluddin. 1997. "Production of sestamibi kit for nuclear imaging." Malaysia.
@misc{etde_662149,
title = {Production of sestamibi kit for nuclear imaging}
author = {Abdullah, Hakim, Zakaria, Ahmad, Yaacob, Hadzri, and Ramli, Jamaluddin}
abstractNote = {One of the research projects undertaken during the implementation of the IAEA Technical Assistance Cooperation Program in our department was inhouse production of sestamibi (MIBI) kit to be labelled with Tc99m pertechnetate for myocardial studies and for malignant tumor imaging. 100 mg raw materials of sestamibi was supplied by IAEA and the kit was prepared based on Janoki recipe. Using 6 mg MIBI, 192 mg glycine, 3.6 mg stannous chloride, 62.4 mg Na sub 4 Po sub 4 and 24 mg cysteine we have prepared 24 vials of MIBI kit under sterile condition and stored in the freezer at -70 degree C. The sterility of the kit was confirmed by microbiological test using cultured method. The stability test was done by labelling the kit with Tc-99m pertechnetate at day 1, 3, 7, 30 and 60 days after kit preparation. Using two system butanone and saline with ITLC the labelling efficiency of Tc-99m (MIBI) was found to be more than 90% in each case. The labelling efficiency was found to maintain at 90% up to 24 hours post reconstitution at room temperature. Biodistribution study was carried out by administering Tc-99m (MIBI) to mice intravenously at the dosage of IOO {mu} Ci per 20 gm body weight. The mice were sacrificed at 3 hours and 24 hours after the dose administration. Blood, heart, lung, intestine, kidney and stomach samples were obtained, weighed and measured for radioactivity using gamma well counter. The data showed that after 3 hours about 60% of the injected dose accumulated in the intestine which was in agreement with IAEA standard. At 24 hours the amount in the heart still remained about 25% of the 3 hour uptake. In house production of MIBI kit is easy, fast and cost effective. The data suggested that the quality of our kit was good enough to be used for further animal research and clinical trials.}
place = {Malaysia}
year = {1997}
month = {Dec}
}