On the use of programmable logical controllers (PLC) in the emergency control schemes for the 750 kV system

Abstract

The energy produced at the Itaipu Power Plant for the Brazilian Interconnected System is transmitted through two different transmission system: -HVDC system, with two bipoles of +- 600 kV, 6300 MW which connect the substation of Foz do Iguacu in the State of Parana, to substation of Ibiuna in the State of Sao Paulo, transmitting the energy generated in 50 Hz units. This system was entirely commissioned on september of 1987. (author) 3 refs., 5 figs.
Authors:
Lima, Roberto Campos de; Oliveira, Mario Cesar Santos de [1] 
  1. FURNAS, Rio de Janeiro, RJ (Brazil)
Publication Date:
Dec 31, 1994
Product Type:
Conference
Report Number:
ETDE-BR-0029; CONF-9405393-
Reference Number:
SCA: 240100; PA: BR-98:0R0051; EDB-98:082292; SN: 98001979868
Resource Relation:
Conference: 4. SEPOPE: symposium of specialists in electric operational and expansion planning, 4. SEPOPE: simposio de especialistas em planejamento da operacao e expansao eletrica, Belo Horizonte (Brazil), 23-27 May 1994; Other Information: PBD: 1994; Related Information: Is Part Of Technical papers presented at the 4. symposium of specialists in electric operational and expansion planning. v. 2; PB: 351 p.; Artigos tecnicos apresentados no 4. simposio de especialistas em planejamento da operacao e expansao eletrica. v. 2
Subject:
24 POWER TRANSMISSION AND DISTRIBUTION; PLANNING; OPERATION; EQUIPMENT PROTECTION DEVICES; RELAYS; INSPECTION; RELIABILITY; POWER SUBSTATIONS; AUTOMATION; SWITCHES; CONTROL EQUIPMENT; CONTROL SYSTEMS
OSTI ID:
659553
Research Organizations:
Itaipu Binacional, Foz do Iguacu, Puerto Rico (Brazil); ELETROBRAS, Rio de Janeiro, RJ (Brazil)
Country of Origin:
Brazil
Language:
English
Other Identifying Numbers:
Other: ON: DE98765511; TRN: BR98R0051
Availability:
OSTI as DE98765511
Submitting Site:
BR
Size:
pp. 341-346
Announcement Date:
Aug 26, 1998

Citation Formats

Lima, Roberto Campos de, and Oliveira, Mario Cesar Santos de. On the use of programmable logical controllers (PLC) in the emergency control schemes for the 750 kV system. Brazil: N. p., 1994. Web.
Lima, Roberto Campos de, & Oliveira, Mario Cesar Santos de. On the use of programmable logical controllers (PLC) in the emergency control schemes for the 750 kV system. Brazil.
Lima, Roberto Campos de, and Oliveira, Mario Cesar Santos de. 1994. "On the use of programmable logical controllers (PLC) in the emergency control schemes for the 750 kV system." Brazil.
@misc{etde_659553,
title = {On the use of programmable logical controllers (PLC) in the emergency control schemes for the 750 kV system}
author = {Lima, Roberto Campos de, and Oliveira, Mario Cesar Santos de}
abstractNote = {The energy produced at the Itaipu Power Plant for the Brazilian Interconnected System is transmitted through two different transmission system: -HVDC system, with two bipoles of +- 600 kV, 6300 MW which connect the substation of Foz do Iguacu in the State of Parana, to substation of Ibiuna in the State of Sao Paulo, transmitting the energy generated in 50 Hz units. This system was entirely commissioned on september of 1987. (author) 3 refs., 5 figs.}
place = {Brazil}
year = {1994}
month = {Dec}
}