Technical-economic evaluation of the utilization of closing resistor in CEMIG extra-high voltage circuit breakers

Abstract

This paper presents the technical and economic studies performed by CEMIG, Companhia Energetica de Minas Gerais, Brazil, concerning the use of closing resistor in its extra-high voltage (EHV) breakers. The analysis emphasizes the advantages which could be achieved with the elimination of the resistor as far as costs and reliability are concerned. This evaluation was motivated by two 500 kV breaker failures resulting from the breakdown of the closing resistor operation mechanism. These occurrences resulted in operative restriction for CEMIG EHV system. The analysis demanded a review of the capability criteria of silicon carbide (Si C) gap arresters, which are still greatly used in CEMIG EHV System, and of the procedures to be applied when carrying out the transient studies. The investigation resulted in the prompt removal of closing resistors from circuit breakers in CEMIG extra-high voltage system generating an economy of approximately U$ 840,00 and an improvement in safety and system reliability. (author) 13 refs., 4 figs., 1 tab.
Authors:
Rocha, Angelica C.O.; Pinto, Roberto del Giudice R.; Teixeira, Jose Cleber; Fonseca, Rodrigo Assuncao; F, Junior, Sebastiao V [1] 
  1. Companhia Energetica de Minas Gerais (CEMIG), Belo Horizonte, MG (Brazil)
Publication Date:
Dec 31, 1994
Product Type:
Conference
Report Number:
ETDE-BR-0029; CONF-9405393-
Reference Number:
SCA: 240100; PA: BR-98:0R0015; EDB-98:082328; SN: 98001979832
Resource Relation:
Conference: 4. SEPOPE: symposium of specialists in electric operational and expansion planning, 4. SEPOPE: simposio de especialistas em planejamento da operacao e expansao eletrica, Belo Horizonte (Brazil), 23-27 May 1994; Other Information: PBD: 1994; Related Information: Is Part Of Technical papers presented at the 4. symposium of specialists in electric operational and expansion planning. v. 2; PB: 351 p.; Artigos tecnicos apresentados no 4. simposio de especialistas em planejamento da operacao e expansao eletrica. v. 2
Subject:
24 POWER TRANSMISSION AND DISTRIBUTION; OPERATION; POWER SYSTEMS; OVERVOLTAGE; SWITCHING CIRCUITS; CIRCUIT BREAKERS; LIGHTNING ARRESTERS; RESISTORS; ECONOMIC ANALYSIS; EVALUATION
OSTI ID:
659481
Research Organizations:
Itaipu Binacional, Foz do Iguacu, Puerto Rico (Brazil); ELETROBRAS, Rio de Janeiro, RJ (Brazil)
Country of Origin:
Brazil
Language:
English
Other Identifying Numbers:
Other: ON: DE98765511; TRN: BR98R0015
Availability:
OSTI as DE98765511
Submitting Site:
BR
Size:
pp. 81-86
Announcement Date:
Aug 26, 1998

Citation Formats

Rocha, Angelica C.O., Pinto, Roberto del Giudice R., Teixeira, Jose Cleber, Fonseca, Rodrigo Assuncao, and F, Junior, Sebastiao V. Technical-economic evaluation of the utilization of closing resistor in CEMIG extra-high voltage circuit breakers. Brazil: N. p., 1994. Web.
Rocha, Angelica C.O., Pinto, Roberto del Giudice R., Teixeira, Jose Cleber, Fonseca, Rodrigo Assuncao, & F, Junior, Sebastiao V. Technical-economic evaluation of the utilization of closing resistor in CEMIG extra-high voltage circuit breakers. Brazil.
Rocha, Angelica C.O., Pinto, Roberto del Giudice R., Teixeira, Jose Cleber, Fonseca, Rodrigo Assuncao, and F, Junior, Sebastiao V. 1994. "Technical-economic evaluation of the utilization of closing resistor in CEMIG extra-high voltage circuit breakers." Brazil.
@misc{etde_659481,
title = {Technical-economic evaluation of the utilization of closing resistor in CEMIG extra-high voltage circuit breakers}
author = {Rocha, Angelica C.O., Pinto, Roberto del Giudice R., Teixeira, Jose Cleber, Fonseca, Rodrigo Assuncao, and F, Junior, Sebastiao V}
abstractNote = {This paper presents the technical and economic studies performed by CEMIG, Companhia Energetica de Minas Gerais, Brazil, concerning the use of closing resistor in its extra-high voltage (EHV) breakers. The analysis emphasizes the advantages which could be achieved with the elimination of the resistor as far as costs and reliability are concerned. This evaluation was motivated by two 500 kV breaker failures resulting from the breakdown of the closing resistor operation mechanism. These occurrences resulted in operative restriction for CEMIG EHV system. The analysis demanded a review of the capability criteria of silicon carbide (Si C) gap arresters, which are still greatly used in CEMIG EHV System, and of the procedures to be applied when carrying out the transient studies. The investigation resulted in the prompt removal of closing resistors from circuit breakers in CEMIG extra-high voltage system generating an economy of approximately U$ 840,00 and an improvement in safety and system reliability. (author) 13 refs., 4 figs., 1 tab.}
place = {Brazil}
year = {1994}
month = {Dec}
}