In this work the TRAC code was used to simulate experiments of natural circulation performed in the first Brazilian integral test facility at (COPESP), Sao Paulo and a rewetting experiment in a single tube test section carried out at CDTN, Belo Horizonte, Brazil. In the first simulation the loop behavior in two transient conditions with different thermal power, namely 20 k W and 120 k W, was verified in the second one the quench front propagation, the liquid mass collected in the carry over measuring tube and the wall temperature at different elevations during the flooding experiment was measured. A comparative analysis, for code consistency, shows a good agreement between the code results and experimental data, except for the quench from velocity. (author). 15 refs, 19 figs, 12 tabs.
Citation Formats
Silva, J.D. da.
Computational simulation of natural circulation and rewetting experiments using the TRAC/PF1 code; Simulacao computacional dos experimentos: circulacao natural no CTE-150 e remolhamento na ITR utilizando o TRAC-PF1.
Brazil: N. p.,
1994.
Web.
Silva, J.D. da.
Computational simulation of natural circulation and rewetting experiments using the TRAC/PF1 code; Simulacao computacional dos experimentos: circulacao natural no CTE-150 e remolhamento na ITR utilizando o TRAC-PF1.
Brazil.
Silva, J.D. da.
1994.
"Computational simulation of natural circulation and rewetting experiments using the TRAC/PF1 code; Simulacao computacional dos experimentos: circulacao natural no CTE-150 e remolhamento na ITR utilizando o TRAC-PF1."
Brazil.
@misc{etde_65448,
title = {Computational simulation of natural circulation and rewetting experiments using the TRAC/PF1 code; Simulacao computacional dos experimentos: circulacao natural no CTE-150 e remolhamento na ITR utilizando o TRAC-PF1}
author = {Silva, J.D. da}
abstractNote = {In this work the TRAC code was used to simulate experiments of natural circulation performed in the first Brazilian integral test facility at (COPESP), Sao Paulo and a rewetting experiment in a single tube test section carried out at CDTN, Belo Horizonte, Brazil. In the first simulation the loop behavior in two transient conditions with different thermal power, namely 20 k W and 120 k W, was verified in the second one the quench front propagation, the liquid mass collected in the carry over measuring tube and the wall temperature at different elevations during the flooding experiment was measured. A comparative analysis, for code consistency, shows a good agreement between the code results and experimental data, except for the quench from velocity. (author). 15 refs, 19 figs, 12 tabs.}
place = {Brazil}
year = {1994}
month = {May}
}
title = {Computational simulation of natural circulation and rewetting experiments using the TRAC/PF1 code; Simulacao computacional dos experimentos: circulacao natural no CTE-150 e remolhamento na ITR utilizando o TRAC-PF1}
author = {Silva, J.D. da}
abstractNote = {In this work the TRAC code was used to simulate experiments of natural circulation performed in the first Brazilian integral test facility at (COPESP), Sao Paulo and a rewetting experiment in a single tube test section carried out at CDTN, Belo Horizonte, Brazil. In the first simulation the loop behavior in two transient conditions with different thermal power, namely 20 k W and 120 k W, was verified in the second one the quench front propagation, the liquid mass collected in the carry over measuring tube and the wall temperature at different elevations during the flooding experiment was measured. A comparative analysis, for code consistency, shows a good agreement between the code results and experimental data, except for the quench from velocity. (author). 15 refs, 19 figs, 12 tabs.}
place = {Brazil}
year = {1994}
month = {May}
}