Abstract
Small separation columns filled with a cellulose exchanger containing salicylic acid as anchor group are used for chromatographic determination of Fe/sup 3 +/, UO/sub 2//sup 2 +/, and Cu/sup 2 +/ in aqueous solutions. The preparation of the cellulose exchanger and the separation procedure are described. The detection limits are approximately /.2 ..mu..g Fe, 5 ..mu..g U and 10 ..mu..g Cu. Within certain concentration ranges chromatographic separation and simultaneous determination of several ions is possible, as shown by the examples Fe/sup 3 +//Cu/sup 2 +/ and UO/sub 2//sup 2 +//Cu/sup 2 +/.
Barba, P;
Lieser, K H
[1]
- Technische Hochschule Darmstadt (Germany, F.R.). Fachbereich Anorganische Chemie und Kernchemie
Citation Formats
Barba, P, and Lieser, K H.
Chromatography on cellulose exchangers - microdetermination of Fe/sup 3 +/, UO/sub 2//sup 2 +/ and Cu/sup 2 +/ ions in aqueous solutions by means of small seperation columns.
Germany: N. p.,
1978.
Web.
Barba, P, & Lieser, K H.
Chromatography on cellulose exchangers - microdetermination of Fe/sup 3 +/, UO/sub 2//sup 2 +/ and Cu/sup 2 +/ ions in aqueous solutions by means of small seperation columns.
Germany.
Barba, P, and Lieser, K H.
1978.
"Chromatography on cellulose exchangers - microdetermination of Fe/sup 3 +/, UO/sub 2//sup 2 +/ and Cu/sup 2 +/ ions in aqueous solutions by means of small seperation columns."
Germany.
@misc{etde_6406593,
title = {Chromatography on cellulose exchangers - microdetermination of Fe/sup 3 +/, UO/sub 2//sup 2 +/ and Cu/sup 2 +/ ions in aqueous solutions by means of small seperation columns}
author = {Barba, P, and Lieser, K H}
abstractNote = {Small separation columns filled with a cellulose exchanger containing salicylic acid as anchor group are used for chromatographic determination of Fe/sup 3 +/, UO/sub 2//sup 2 +/, and Cu/sup 2 +/ in aqueous solutions. The preparation of the cellulose exchanger and the separation procedure are described. The detection limits are approximately /.2 ..mu..g Fe, 5 ..mu..g U and 10 ..mu..g Cu. Within certain concentration ranges chromatographic separation and simultaneous determination of several ions is possible, as shown by the examples Fe/sup 3 +//Cu/sup 2 +/ and UO/sub 2//sup 2 +//Cu/sup 2 +/.}
journal = []
volume = {291:3}
journal type = {AC}
place = {Germany}
year = {1978}
month = {Jul}
}
title = {Chromatography on cellulose exchangers - microdetermination of Fe/sup 3 +/, UO/sub 2//sup 2 +/ and Cu/sup 2 +/ ions in aqueous solutions by means of small seperation columns}
author = {Barba, P, and Lieser, K H}
abstractNote = {Small separation columns filled with a cellulose exchanger containing salicylic acid as anchor group are used for chromatographic determination of Fe/sup 3 +/, UO/sub 2//sup 2 +/, and Cu/sup 2 +/ in aqueous solutions. The preparation of the cellulose exchanger and the separation procedure are described. The detection limits are approximately /.2 ..mu..g Fe, 5 ..mu..g U and 10 ..mu..g Cu. Within certain concentration ranges chromatographic separation and simultaneous determination of several ions is possible, as shown by the examples Fe/sup 3 +//Cu/sup 2 +/ and UO/sub 2//sup 2 +//Cu/sup 2 +/.}
journal = []
volume = {291:3}
journal type = {AC}
place = {Germany}
year = {1978}
month = {Jul}
}